-
Prospects of fast timing detectors for particle identification at future Higgs factories
Authors:
Bohdan Dudar,
Jenny List,
Ulrich Einhaus,
Remi Ete
Abstract:
We present an overview of a study on precise mass reconstruction and identification of charged hadrons ($π^{\pm}$, $K^{\pm}$, $p$) using time-of-flight measurements in the electromagnetic calorimeter of a typical Higgs factory detector. Time-of-flight measurements can take advantage of fast timing Si sensors with a time resolution in the order of 10 ps. A precise time-of-flight measurement might c…
▽ More
We present an overview of a study on precise mass reconstruction and identification of charged hadrons ($π^{\pm}$, $K^{\pm}$, $p$) using time-of-flight measurements in the electromagnetic calorimeter of a typical Higgs factory detector. Time-of-flight measurements can take advantage of fast timing Si sensors with a time resolution in the order of 10 ps. A precise time-of-flight measurement might contribute to the kaon mass determination and can improve particle identification in the momentum regions inaccessible for the $dE/dx$ method. In this contribution, we discuss the current status and the challenges of the time-of-flight approach for a precise reconstruction of charged hadron masses.
△ Less
Submitted 26 May, 2021;
originally announced May 2021.
-
EUDAQ2 -- A Flexible Data Acquisition Software Framework for Common Test Beams
Authors:
Y. Liu,
M. S. Amjad,
P. Baesso,
D. Cussans,
J. Dreyling-Eschweiler,
R. Ete,
I. Gregor,
L. Huth,
A. Irles,
H. Jansen,
K. Krueger,
J. Kvasnicka,
R. Peschke,
E. Rossi,
A. Rummler,
F. Sefkow,
M. Stanitzki,
M. Wing,
M. Wu
Abstract:
The data acquisition software framework, EUDAQ, was originally developed to read out data from the EUDET-type pixel telescopes. This was successfully used in many test beam campaigns in which an external position and time reference were required. The software has recently undergone a significant upgrade, EUDAQ2, which is a generic, modern and modular system for use by many different detector types…
▽ More
The data acquisition software framework, EUDAQ, was originally developed to read out data from the EUDET-type pixel telescopes. This was successfully used in many test beam campaigns in which an external position and time reference were required. The software has recently undergone a significant upgrade, EUDAQ2, which is a generic, modern and modular system for use by many different detector types, ranging from tracking detectors to calorimeters. EUDAQ2 is suited as an overarching software that links individual detector readout systems and simplifies the integration of multiple detectors. The framework itself supports several triggering and event building modes. This flexibility makes test beams with multiple detectors significantly easier and more efficient, as EUDAQ2 can adapt to the characteristics of each detector prototype during testing. The system has been thoroughly tested during multiple test beams involving different detector prototypes. EUDAQ2 has now been released and is freely available under an open-source license.
△ Less
Submitted 4 September, 2019; v1 submitted 23 July, 2019;
originally announced July 2019.
-
Resistive Plate Chamber Digitization in a Hadronic Shower Environment
Authors:
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
J. Apostolakis,
G. Folger,
C. Grefe,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
C. Carloganu,
V. Français,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
S. Cauwenbergh,
M. Tytgat,
A. Pingault,
N. Zaganidis,
E. Brianne,
A. Ebrahimi
, et al. (103 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, e…
▽ More
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, electrons and pions of different energies at the CERN Super Proton Synchrotron. To be able to study the performance of such a calorimeter in future experiments it is important to ensure reliable simulation of its response. In this paper we present our prototype simulation performed with GEANT4 and the digitization procedure achieved with an algorithm called SimDigital. A detailed description of this algorithm is given and the methods to determinate its parameters using muon tracks and electromagnetic showers are explained. The comparison with hadronic shower data shows a good agreement up to 50 GeV. Discrepancies are observed at higher energies. The reasons for these differences are investigated.
△ Less
Submitted 15 April, 2016;
originally announced April 2016.
-
First results of the CALICE SDHCAL technological prototype
Authors:
V. Buridon,
C. Combaret,
L. Caponetto,
R. Eté,
G. Garillot,
G. Grenier,
R. Han,
J. C. Ianigro,
R. Kieffer,
I. Laktineh,
N. Lumb,
H. Mathez,
L. Mirabito,
A. Petrukhin,
A. Steen,
J. Berenguer Antequera,
E. Calvo Alamillo,
M. -C. Fouz,
J. Marin,
J. Puerta-Pelayo,
A. Verdugo,
E. Cortina Gil,
S. Mannai,
S. Cauwenbergh,
M. Tytgat
, et al. (96 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the CERN SPS. The prototype with its 48 active layers, made of Glass Resistive Plate Chambers and their embedded readout electronics, was run in triggerless and power-pulsing mode. The performance of the SDH…
▽ More
The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the CERN SPS. The prototype with its 48 active layers, made of Glass Resistive Plate Chambers and their embedded readout electronics, was run in triggerless and power-pulsing mode. The performance of the SDHCAL during the test beam was found to be very satisfactory with an efficiency exceeding 90% for almost all of the 48 active layers. A linear response (within 5%) and a good energy resolution are obtained for a large range of hadronic energies (5-80GeV) by applying appropriate calibration coefficients to the collected data for both the Digital (Binary) and the Semi-Digital (Multi-threshold) modes of the SDHCAL prototype. The Semi-Digital mode shows better performance at energies exceeding 30GeV
△ Less
Submitted 20 March, 2016; v1 submitted 6 February, 2016;
originally announced February 2016.
-
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
L. Xia,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh,
G. C. Blazey,
A. Dyshkant,
K. Francis,
J. G. R. Lima,
R. Salcido,
V. Zutshi,
F. Salvatore,
K. Kawagoe,
Y. Miyazaki,
Y. Sudo
, et al. (147 additional authors not shown)
Abstract:
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simul…
▽ More
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.
△ Less
Submitted 15 March, 2015; v1 submitted 8 December, 2014;
originally announced December 2014.
-
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters J. Repond,
J. Schlereth,
L. Xia E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki J. Apostolakis,
S. Arfaoui,
M. Benoit
, et al. (188 additional authors not shown)
Abstract:
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m…
▽ More
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.
△ Less
Submitted 21 July, 2014; v1 submitted 25 April, 2014;
originally announced April 2014.