-
Design of a high power production target for the Beam Dump Facility at CERN
Authors:
E. Lopez Sola,
M. Calviani,
P. Avigni,
M. Battistin,
J. Busom Descarrega,
J. Canhoto Espadanal,
M. A. Fraser,
S. Gilardoni,
B. Goddard,
D. Grenier,
R. Jacobsson,
K. Kershaw,
M. Lamont,
A. Perillo-Marcone,
M. Pandey,
B. Riffaud,
S. Sgobba,
V. Vlachoudis,
L. Zuccalli
Abstract:
The Beam Dump Facility (BDF) project is a proposed general-purpose facility at CERN, dedicated to beam dump and fixed target experiments. In its initial phase, the facility is foreseen to be exploited by the Search for Hidden Particles (SHiP) experiment. Physics requirements call for a pulsed 400 GeV/c proton beam as well as the highest possible number of protons on target (POT) each year of opera…
▽ More
The Beam Dump Facility (BDF) project is a proposed general-purpose facility at CERN, dedicated to beam dump and fixed target experiments. In its initial phase, the facility is foreseen to be exploited by the Search for Hidden Particles (SHiP) experiment. Physics requirements call for a pulsed 400 GeV/c proton beam as well as the highest possible number of protons on target (POT) each year of operation, in order to search for feebly interacting particles. The target/dump assembly lies at the heart of the facility, with the aim of safely absorbing the full high intensity Super Proton Synchrotron (SPS) beam, while maximizing the production of charmed and beauty mesons. High-Z materials are required for the target/dump, in order to have the shortest possible absorber and reduce muon background for the downstream experiment. The high average power deposited on target (305 kW) creates a challenge for heat removal. During the BDF facility Comprehensive Design Study (CDS), launched by CERN in 2016, extensive studies have been carried out in order to define and assess the target assembly design. These studies are described in the present contribution, which details the proposed design of the BDF production target, as well as the material selection process and the optimization of the target configuration and beam dilution. One of the specific challenges and novelty of this work is the need to consider new target materials, such as a molybdenum alloy (TZM) as core absorbing material and Ta2.5W as cladding. Thermo-structural and fluid dynamics calculations have been performed to evaluate the reliability of the target and its cooling system under beam operation. In the framework of the target comprehensive design, a preliminary mechanical design of the full target assembly has also been carried out, assessing the feasibility of the whole target system.
△ Less
Submitted 30 October, 2019; v1 submitted 5 April, 2019;
originally announced April 2019.
-
MARTA: A high-energy cosmic-ray detector concept with high-accuracy muon measurement
Authors:
P. Abreu,
S. Andringa,
P. Assis,
A. Blanco,
V. Barbosa Martins,
P. Brogueira,
N. Carolino,
L. Cazon,
M. Cerda,
G. Cernicchiaro,
R. Colalillo,
R. Conceição,
O. Cunha,
R. M. de Almeida,
V. de Souza,
F. Diogo,
C. Dobrigkeit,
J. Espadanal,
C. Espirito-Santo,
M. Ferreira,
P. Ferreira,
P. Fonte,
U. Giaccari,
P. Gonçalves,
F. Guarino
, et al. (20 additional authors not shown)
Abstract:
A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used…
▽ More
A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used in air shower arrays. The combination of the two detectors in a single, compact detector unit provides a unique measurement that opens rich possibilities in the study of air showers.
△ Less
Submitted 20 April, 2018; v1 submitted 20 December, 2017;
originally announced December 2017.
-
3D simulation for Cherenkov emissions in Extensive Air Showers
Authors:
João Espadanal,
Patrícia Gonçalves
Abstract:
The development of a 3-dimensional simulation for Cherenkov photon emissions in Extensive Air Showers (EAS) is reported in this paper. CORSIKA is the most widely used Monte-Carlo generator for the description of EAS, but it is not recommended to calculate Cherenkov light emissions for EAS at ultra high energies due to the enormous amount of data storage and running time required. The presented Bin…
▽ More
The development of a 3-dimensional simulation for Cherenkov photon emissions in Extensive Air Showers (EAS) is reported in this paper. CORSIKA is the most widely used Monte-Carlo generator for the description of EAS, but it is not recommended to calculate Cherenkov light emissions for EAS at ultra high energies due to the enormous amount of data storage and running time required. The presented BinTheSky is a framework to simulate the Cherenkov light emissions using the spatial information produced by Monte-Carlo generators. The light is emitted in the shower, propagated and attenuated to the ground. The framework enables one to calculate the light spatial, timing and directional distributions at the ground or at a given altitude, whereas the usual approach of Ultra High Energy Cosmic Ray experiments relies on the simulation of the longitudinal shower development and on parametrizations of the transverse shower distributions.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
Search for photons with energies above 10$^{18}$ eV using the hybrid detector of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila,
A. M. Badescu,
A. Balaceanu,
R. J. Barreira Luz,
J. J. Beatty
, et al. (375 additional authors not shown)
Abstract:
A search for ultra-high energy photons with energies above 1 EeV is performed using nine years of data collected by the Pierre Auger Observatory in hybrid operation mode. An unprecedented separation power between photon and hadron primaries is achieved by combining measurements of the longitudinal air-shower development with the particle content at ground measured by the fluorescence and surface d…
▽ More
A search for ultra-high energy photons with energies above 1 EeV is performed using nine years of data collected by the Pierre Auger Observatory in hybrid operation mode. An unprecedented separation power between photon and hadron primaries is achieved by combining measurements of the longitudinal air-shower development with the particle content at ground measured by the fluorescence and surface detectors, respectively. Only three photon candidates at energies 1 - 2 EeV are found, which is compatible with the expected hadron-induced background. Upper limits on the integral flux of ultra-high energy photons of 0.038, 0.010, 0.009, 0.008 and 0.007 km$^{-2}$ sr$^{-1}$ yr$^{-1}$ are derived at 95% C.L. for energy thresholds of 1, 2, 3, 5 and 10 EeV. These limits bound the fractions of photons in the all-particle integral flux below 0.14%, 0.17%, 0.42%, 0.86% and 2.9%. For the first time the photon fraction at EeV energies is constrained at the sub-percent level. The improved limits are below the flux of diffuse photons predicted by some astrophysical scenarios for cosmogenic photon production. The new results rule-out the early top-down models $-$ in which ultra-high energy cosmic rays are produced by, e.g., the decay of super-massive particles $-$ and challenge the most recent super-heavy dark matter models.
△ Less
Submitted 28 September, 2020; v1 submitted 5 December, 2016;
originally announced December 2016.
-
Testing Hadronic Interactions at Ultrahigh Energies with Air Showers Measured by the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
J. Allen,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila
, et al. (413 additional authors not shown)
Abstract:
Ultrahigh energy cosmic ray air showers probe particle physics at energies beyond the reach of accelerators. Here we introduce a new method to test hadronic interaction models without relying on the absolute energy calibration, and apply it to events with primary energy 6-16 EeV (E_CM = 110-170 TeV), whose longitudinal development and lateral distribution were simultaneously measured by the Pierre…
▽ More
Ultrahigh energy cosmic ray air showers probe particle physics at energies beyond the reach of accelerators. Here we introduce a new method to test hadronic interaction models without relying on the absolute energy calibration, and apply it to events with primary energy 6-16 EeV (E_CM = 110-170 TeV), whose longitudinal development and lateral distribution were simultaneously measured by the Pierre Auger Observatory. The average hadronic shower is 1.33 +- 0.16 (1.61 +- 0.21) times larger than predicted using the leading LHC-tuned models EPOS-LHC (QGSJetII-04), with a corresponding excess of muons.
△ Less
Submitted 31 October, 2016; v1 submitted 26 October, 2016;
originally announced October 2016.
-
Constraints on hadronic models in extensive air showers with the Pierre Auger Observatory
Authors:
J. Espadanal
Abstract:
Extensive air showers initiated by ultra-high energy cosmic rays are sensitive to the details of hadronic interactions models, so we present the main results obtained using the data of the Pierre Auger Observatory. The depth at which the maximum of the electromagnetic development takes place is the most sensitive parameter to infer the nature of the cosmic rays. However, the hadronic models cannot…
▽ More
Extensive air showers initiated by ultra-high energy cosmic rays are sensitive to the details of hadronic interactions models, so we present the main results obtained using the data of the Pierre Auger Observatory. The depth at which the maximum of the electromagnetic development takes place is the most sensitive parameter to infer the nature of the cosmic rays. However, the hadronic models cannot describe consistently the maximum and the muon measurements at energies higher than those reached at the LHC.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
Sensitivity of EAS measurements to the energy spectrum of muons
Authors:
J. Espadanal,
L. Cazon,
R. Conceição
Abstract:
We have studied how the energy spectrum of muons at production affects some of the most common measurements related to muons in extensive air shower studies, namely, the number of muons at the ground, the slope of the lateral distribution of muons, the apparent muon production depth, and the arrival time delay of muons at ground. We found that by changing the energy spectrum by an amount consisten…
▽ More
We have studied how the energy spectrum of muons at production affects some of the most common measurements related to muons in extensive air shower studies, namely, the number of muons at the ground, the slope of the lateral distribution of muons, the apparent muon production depth, and the arrival time delay of muons at ground. We found that by changing the energy spectrum by an amount consistent with the difference between current models (namely EPOS-LHC and QGSjet-II.04), the muon surface density at ground increases $5\%$ at $20^\circ$ zenith angle and $17\%$ at $60^\circ$ zenith angle. This effect introduces a zenith angle dependence on the reconstructed number of muons which might be experimentally observed. The maximum of the muon production depth distribution at $40^\circ$ increases $\sim10\text{ g/cm}^2$ and $\sim0\text{ g/cm}^2$ at $60^\circ$, which, from pure geometrical considerations, increases the arrival time delay of muons. There is an extra contribution to the delay due to the subluminal velocities of muons of the order of $\sim3$ ns at all zenith angles. Finally, changes introduced in the logarithmic slope of the lateral density function are less than 2%.
△ Less
Submitted 24 November, 2016; v1 submitted 22 July, 2016;
originally announced July 2016.
-
Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy
Authors:
The Pierre Auger Collaboration,
Alexander Aab,
Pedro Abreu,
Marco Aglietta,
Eun-Joo Ahn,
Imen Al Samarai,
Ivone Albuquerque,
Ingomar Allekotte,
Patrick Allison,
Alejandro Almela,
Jesus Alvarez Castillo,
Jaime Alvarez-Muñiz,
Rafael Alves Batista,
Michelangelo Ambrosio,
Amin Aminaei,
Gioacchino Alex Anastasi,
Luis Anchordoqui,
Sofia Andringa,
Carla Aramo,
Fernando Arqueros,
Nicusor Arsene,
Hernán Gonzalo Asorey,
Pedro Assis,
Julien Aublin,
Gualberto Avila
, et al. (425 additional authors not shown)
Abstract:
We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cos…
▽ More
We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.
△ Less
Submitted 21 June, 2016; v1 submitted 9 May, 2016;
originally announced May 2016.
-
Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin
, et al. (429 additional authors not shown)
Abstract:
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary…
▽ More
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. The completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.
△ Less
Submitted 12 May, 2016; v1 submitted 5 May, 2016;
originally announced May 2016.
-
Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila
, et al. (426 additional authors not shown)
Abstract:
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected…
▽ More
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used for cross-checks that indeed we reach nanosecond-scale timing accuracy by this correction. First, we operate a "beacon transmitter" which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.
△ Less
Submitted 15 February, 2016; v1 submitted 7 December, 2015;
originally announced December 2015.
-
The IceCube Neutrino Observatory, the Pierre Auger Observatory and the Telescope Array: Joint Contribution to the 34th International Cosmic Ray Conference (ICRC 2015)
Authors:
IceCube Collaboration,
M. G. Aartsen,
K. Abraham,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
D. Altmann,
T. Anderson,
I. Ansseau,
M. Archinger,
C. Arguelles,
T. C. Arlen,
J. Auffenberg,
X. Bai,
S. W. Barwick,
V. Baum,
R. Bay,
J. J. Beatty,
J. Becker Tjus,
K. -H. Becker,
E. Beiser,
S. BenZvi,
P. Berghaus
, et al. (869 additional authors not shown)
Abstract:
We have conducted three searches for correlations between ultra-high energy cosmic rays detected by the Telescope Array and the Pierre Auger Observatory, and high-energy neutrino candidate events from IceCube. Two cross-correlation analyses with UHECRs are done: one with 39 cascades from the IceCube `high-energy starting events' sample and the other with 16 high-energy `track events'. The angular…
▽ More
We have conducted three searches for correlations between ultra-high energy cosmic rays detected by the Telescope Array and the Pierre Auger Observatory, and high-energy neutrino candidate events from IceCube. Two cross-correlation analyses with UHECRs are done: one with 39 cascades from the IceCube `high-energy starting events' sample and the other with 16 high-energy `track events'. The angular separation between the arrival directions of neutrinos and UHECRs is scanned over. The same events are also used in a separate search using a maximum likelihood approach, after the neutrino arrival directions are stacked. To estimate the significance we assume UHECR magnetic deflections to be inversely proportional to their energy, with values $3^\circ$, $6^\circ$ and $9^\circ$ at 100 EeV to allow for the uncertainties on the magnetic field strength and UHECR charge. A similar analysis is performed on stacked UHECR arrival directions and the IceCube sample of through-going muon track events which were optimized for neutrino point-source searches.
△ Less
Submitted 6 November, 2015;
originally announced November 2015.
-
Measurement of the Muon content of Extensive Air Showers with the Pierre Auger Observatory
Authors:
J. Espadanal
Abstract:
Several methods developed within the Pierre Auger Collaboration for the estimation of the muonic component of the Extensive Air Showers observed in the surface Cherenkov detectors are described. The results derived from the data show a deficit of muons predicted by the current hadronic interactions models at ultra-high energies.
Several methods developed within the Pierre Auger Collaboration for the estimation of the muonic component of the Extensive Air Showers observed in the surface Cherenkov detectors are described. The results derived from the data show a deficit of muons predicted by the current hadronic interactions models at ultra-high energies.
△ Less
Submitted 20 May, 2015;
originally announced May 2015.
-
Measurement of the cosmic ray spectrum above $4{\times}10^{18}$ eV using inclined events detected with the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
Alexander Aab,
Pedro Abreu,
Marco Aglietta,
Eun-Joo Ahn,
Imen Al Samarai,
Ivone Albuquerque,
Ingomar Allekotte,
Patrick Allison,
Alejandro Almela,
Jesus Alvarez Castillo,
Jaime Alvarez-Muñiz,
Rafael Alves Batista,
Michelangelo Ambrosio,
Amin Aminaei,
Luis Anchordoqui,
Sofia Andringa,
Carla Aramo,
Victor Manuel Aranda,
Fernando Arqueros,
Nicusor Arsene,
Hernán Gonzalo Asorey,
Pedro Assis,
Julien Aublin,
Maximo Ave
, et al. (439 additional authors not shown)
Abstract:
A measurement of the cosmic-ray spectrum for energies exceeding $4{\times}10^{18}$ eV is presented, which is based on the analysis of showers with zenith angles greater than $60^{\circ}$ detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above $5.3{\times}10^{18}$ eV, the "ankle", the fl…
▽ More
A measurement of the cosmic-ray spectrum for energies exceeding $4{\times}10^{18}$ eV is presented, which is based on the analysis of showers with zenith angles greater than $60^{\circ}$ detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above $5.3{\times}10^{18}$ eV, the "ankle", the flux can be described by a power law $E^{-γ}$ with index $γ=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)}$ followed by a smooth suppression region. For the energy ($E_\text{s}$) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find $E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19}$ eV.
△ Less
Submitted 24 November, 2015; v1 submitted 26 March, 2015;
originally announced March 2015.
-
Reconstruction of inclined air showers detected with the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
M. Ahlers,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
J. Allen,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
C. Aramo,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave
, et al. (463 additional authors not shown)
Abstract:
We describe the method devised to reconstruct inclined cosmic-ray air showers with zenith angles greater than $60^\circ$ detected with the surface array of the Pierre Auger Observatory. The measured signals at the ground level are fitted to muon density distributions predicted with atmospheric cascade models to obtain the relative shower size as an overall normalization parameter. The method is ev…
▽ More
We describe the method devised to reconstruct inclined cosmic-ray air showers with zenith angles greater than $60^\circ$ detected with the surface array of the Pierre Auger Observatory. The measured signals at the ground level are fitted to muon density distributions predicted with atmospheric cascade models to obtain the relative shower size as an overall normalization parameter. The method is evaluated using simulated showers to test its performance. The energy of the cosmic rays is calibrated using a sub-sample of events reconstructed with both the fluorescence and surface array techniques. The reconstruction method described here provides the basis of complementary analyses including an independent measurement of the energy spectrum of ultra-high energy cosmic rays using very inclined events collected by the Pierre Auger Observatory.
△ Less
Submitted 11 July, 2014;
originally announced July 2014.
-
The Lateral Trigger Probability function for the Ultra-High Energy Cosmic Ray Showers detected by the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. F. M. Albuquerque,
D. Allard,
I. Allekotte,
J. Allen,
P. Allison,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
A. Aminaei,
L. Anchordoqui,
S. Andringa,
T. Antičić,
A. Anzalone,
C. Aramo,
E. Arganda,
F. Arqueros,
H. Asorey,
P. Assis,
J. Aublin,
M. Ave,
M. Avenier
, et al. (473 additional authors not shown)
Abstract:
In this paper we introduce the concept of Lateral Trigger Probability (LTP) function, i.e., the probability for an extensive air shower (EAS) to trigger an individual detector of a ground based array as a function of distance to the shower axis, taking into account energy, mass and direction of the primary cosmic ray. We apply this concept to the surface array of the Pierre Auger Observatory consi…
▽ More
In this paper we introduce the concept of Lateral Trigger Probability (LTP) function, i.e., the probability for an extensive air shower (EAS) to trigger an individual detector of a ground based array as a function of distance to the shower axis, taking into account energy, mass and direction of the primary cosmic ray. We apply this concept to the surface array of the Pierre Auger Observatory consisting of a 1.5 km spaced grid of about 1600 water Cherenkov stations. Using Monte Carlo simulations of ultra-high energy showers the LTP functions are derived for energies in the range between 10^{17} and 10^{19} eV and zenith angles up to 65 degs. A parametrization combining a step function with an exponential is found to reproduce them very well in the considered range of energies and zenith angles. The LTP functions can also be obtained from data using events simultaneously observed by the fluorescence and the surface detector of the Pierre Auger Observatory (hybrid events). We validate the Monte-Carlo results showing how LTP functions from data are in good agreement with simulations.
△ Less
Submitted 28 November, 2011;
originally announced November 2011.