-
A tunable dielectric resonator for axion searches at 11 GHz
Authors:
R. Di Vora,
A. Gardikiotis,
C. Braggio,
G. Carugno,
A. Lombardi,
A. Ortolan,
G. Ruoso
Abstract:
In the context of axion search with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion-photon coupling with the required sensitivity to reach the QCD axion models. Higher order modes in dielectrically-loaded cavities allow for higher effective volumes and larger quality factors compared to basi…
▽ More
In the context of axion search with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion-photon coupling with the required sensitivity to reach the QCD axion models. Higher order modes in dielectrically-loaded cavities allow for higher effective volumes and larger quality factors compared to basic cylindrical cavities, but a proper cavity frequency tuning mechanism to probe broad axion mass ranges is yet not available. In this work, we report about the design and construction of a tunable prototype of a single-shell dielectric resonator with its axion-sensitive pseudo-TM$_{030}$ high-order mode at about 11 GHz frequency. A clamshell tuning method previously tested for empty cylindrical resonators has been perfected for this geometry through simulations and in situ tests conducted at cryogenic temperature. Tuning is accomplished in a range of about 2 $\%$ the central frequency, without significantly impacting the quality factor of about 175000. The experimental results presented in this work demonstrate the tunability of this type of resonator, definitely confirming its applicability to high frequency axion searches.
△ Less
Submitted 10 October, 2024;
originally announced October 2024.
-
A new class of axion haloscope resonators: the polygonal coaxial cavity
Authors:
Raffaele Di Vora,
Caterina Braggio,
Giovanni Carugno,
Antonios Gardikiotis,
Augusto Lombardi,
Antonello Ortolan,
Giuseppe Ruoso
Abstract:
In the search for axionic Dark Matter, the high frequency part of the QCD axion parameter space is favored, as indicated by both cosmological and astrophysical arguments and recent indications from lattice QCD calculations. To extend the probing range of cavity haloscopes, solutions addressing the unfavorable scaling of cavity volume with frequency must be developed. Here, we present a novel type…
▽ More
In the search for axionic Dark Matter, the high frequency part of the QCD axion parameter space is favored, as indicated by both cosmological and astrophysical arguments and recent indications from lattice QCD calculations. To extend the probing range of cavity haloscopes, solutions addressing the unfavorable scaling of cavity volume with frequency must be developed. Here, we present a novel type of high-volume thin shell resonator for high frequency haloscope dark matter searches. The cavity is formed by two nested and coaxial right angle polygonal prisms enclosed within two flat endcaps. For the axion-sensitive (pseudo-)TM010 mode, finite element simulations yield form factor of the order of 0.8 and Q factor of the order of 60000 for a copper cavity at 4$\,$K. High tunability of up to $\sim 5\%$ is achieved by reciprocal rotation of the two prisms, without significant changes in haloscope sensitivity. A prototype aluminium hexagonal cavity was built and tested, confirming the main characteristics of the design.
△ Less
Submitted 21 March, 2024;
originally announced March 2024.
-
Quantum-enhanced sensing of axion dark matter with a transmon-based single microwave photon counter
Authors:
C. Braggio,
L. Balembois,
R. Di Vora,
Z. Wang,
J. Travesedo,
L. Pallegoix,
G. Carugno,
A. Ortolan,
G. Ruoso,
U. Gambardella,
D. D'Agostino,
P. Bertet,
E. Flurin
Abstract:
We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor 3-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by th…
▽ More
We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor 3-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background, and enables tuning of the cavity frequency to probe different axion masses. With this apparatus we enhance by a factor 20 the search speed that can be reached with quantum-limited linear amplifiers, and set a new standard for probing the existence of axions with resonant detectors.
△ Less
Submitted 7 March, 2024; v1 submitted 4 March, 2024;
originally announced March 2024.
-
Search for Axion dark matter with the QUAX-LNF tunable haloscope
Authors:
A. Rettaroli,
D. Alesini,
D. Babusci,
C. Braggio,
G. Carugno,
D. D'Agostino,
A. D'Elia,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
A. Gardikiotis,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
G. Ruoso,
S. Tocci,
G. Vidali
Abstract:
We report the first experimental results obtained with the new haloscope of the QUAX experiment located at Laboratori Nazionali di Frascati of INFN (LNF). The haloscope is composed of a OFHC Cu resonant cavity cooled down to about 30 mK and immersed in a magnetic field of 8 T. The cavity frequency was varied in a 6 MHz range between 8.831496 and 8.83803 GHz. This corresponds to a previously unprob…
▽ More
We report the first experimental results obtained with the new haloscope of the QUAX experiment located at Laboratori Nazionali di Frascati of INFN (LNF). The haloscope is composed of a OFHC Cu resonant cavity cooled down to about 30 mK and immersed in a magnetic field of 8 T. The cavity frequency was varied in a 6 MHz range between 8.831496 and 8.83803 GHz. This corresponds to a previously unprobed mass range between 36.52413 and 36.5511 $μ$eV. We don't observe any excess in the power spectrum and set limits on the axion-photon coupling in this mass range down to $g_{aγγ} < 0.861 \times 10^{-13}$ GeV$^{-1}$ with the confidence level set at $90\%$.
△ Less
Submitted 15 May, 2024; v1 submitted 29 February, 2024;
originally announced February 2024.
-
Search for galactic axions with a traveling wave parametric amplifier
Authors:
R. Di Vora,
A. Lombardi,
A. Ortolan,
R. Pengo,
G. Ruoso,
C. Braggio,
G. Carugno,
L. Taffarello,
G. Cappelli,
N. Crescini,
M. Esposito,
L. Planat,
A. Ranadive,
N. Roch,
D. Alesini,
D. Babusci,
A. D'Elia,
D. Di Gioacchino,
C. Gatti,
C. Ligi,
G. Maccarrone,
A. Rettaroli,
S. Tocci,
D. D'Agostino,
U. Gambardella
, et al. (2 additional authors not shown)
Abstract:
A traveling wave parametric amplifier has been integrated in the haloscope of the QUAX experiment. A search for dark matter axions has been performed with a high Q dielectric cavity immersed in a 8 T magnetic field and read by a detection chain having a system noise temperature of about 2.1 K at the frequency of 10.353 GHz. Scanning has been conducted by varying the cavity frequency using sapphire…
▽ More
A traveling wave parametric amplifier has been integrated in the haloscope of the QUAX experiment. A search for dark matter axions has been performed with a high Q dielectric cavity immersed in a 8 T magnetic field and read by a detection chain having a system noise temperature of about 2.1 K at the frequency of 10.353 GHz. Scanning has been conducted by varying the cavity frequency using sapphire rods immersed into the cavity. At multiple operating frequencies, the sensitivity of the instrument was at the level of viable axion models.
△ Less
Submitted 15 April, 2023;
originally announced April 2023.
-
Search for galactic axions with a high-Q dielectric cavity
Authors:
D. Alesini,
D. Babusci,
C. Braggio,
G. Carugno,
N. Crescini,
D. DAgostino,
A. D'Elia,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
R. Pengo,
A. Rettaroli,
G. Ruoso,
L. Taffarello,
S. Tocci
Abstract:
A haloscope of the QUAX--$aγ$ experiment, composed of an high-Q resonant cavity immersed in a 8 T magnet and cooled to $\sim 4.5$~K is operated to search for galactic axion with mass $m_a\simeq42.8~μ\text{eV}$. The design of the cavity with hollow dielectric cylinders concentrically inserted in a OFHC Cu cavity, allowed us to maintain a loaded quality-factor Q $\sim 300000$ during the measurements…
▽ More
A haloscope of the QUAX--$aγ$ experiment, composed of an high-Q resonant cavity immersed in a 8 T magnet and cooled to $\sim 4.5$~K is operated to search for galactic axion with mass $m_a\simeq42.8~μ\text{eV}$. The design of the cavity with hollow dielectric cylinders concentrically inserted in a OFHC Cu cavity, allowed us to maintain a loaded quality-factor Q $\sim 300000$ during the measurements in presence of magnetic field. Through the cavity tuning mechanism it was possible to modulate the resonance frequency of the haloscope in the region $10.35337-10.35345$~GHz and thus acquire different dataset at different resonance frequencies. Acquiring each dataset for about 50 minutes, combining them and correcting for the axion's signal estimation-efficiency we set a limit on the axion-photon coupling $g_{aγγ}< 0.731\times10^{-13}$ GeV$^{-1}$ with the confidence level set at $90\%$.
△ Less
Submitted 26 August, 2022;
originally announced August 2022.
-
Search for invisible axion dark matter of mass m$_a=43~μ$eV with the QUAX--$aγ$ experiment
Authors:
D. Alesini,
C. Braggio,
G. Carugno,
N. Crescini,
D. D'Agostino,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
R. Pengo,
A. Rettaroli,
G. Ruoso,
L. Taffarello,
S. Tocci
Abstract:
A haloscope of the QUAX--$aγ$ experiment composed of an oxygen-free high thermal conductivity-Cu cavity inside an 8.1 T magnet and cooled to $\sim200$ mK is put in operation for the search of galactic axion with mass $m_a\simeq43~μ\text{eV}$. The power emitted by the resonant cavity is amplified with a Josephson parametric amplifier whose noise fluctuations are at the standard quantum limit. With…
▽ More
A haloscope of the QUAX--$aγ$ experiment composed of an oxygen-free high thermal conductivity-Cu cavity inside an 8.1 T magnet and cooled to $\sim200$ mK is put in operation for the search of galactic axion with mass $m_a\simeq43~μ\text{eV}$. The power emitted by the resonant cavity is amplified with a Josephson parametric amplifier whose noise fluctuations are at the standard quantum limit. With the data collected in about 1 h at the cavity frequency $ν_c=10.40176$ GHz, the experiment reaches the sensitivity necessary for the detection of galactic QCD-axion, setting the $90\%$ confidence level limit to the axion-photon coupling $g_{aγγ}<0.639\times10^{-13}$ GeV$^{-1}$.
△ Less
Submitted 26 May, 2021; v1 submitted 17 December, 2020;
originally announced December 2020.
-
Realization of a high quality factor resonator with hollow dielectric cylinders for axion searches
Authors:
D. Alesini,
C. Braggio,
G. Carugno,
N. Crescini,
D. D' Agostino,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
R. Pengo,
C. Pira,
A. Rettaroli,
G. Ruoso,
L. Taffarello,
S. Tocci
Abstract:
The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the temperatures 300 K and 4 K obtaining $\mbox{Q}_{300\mbox{K}}=(150,000\pm 2,000)$ and $\mbox{Q}_{4\mbox{K}}=(720,000\pm 10,000)$respectively, the latter corresponding…
▽ More
The realization and characterization of a high quality factor resonator composed of two hollow-dielectric cylinders with its pseudo-TM$_{030}$ mode resonating at 10.9 GHz frequency is discussed. The quality factor was measured at the temperatures 300 K and 4 K obtaining $\mbox{Q}_{300\mbox{K}}=(150,000\pm 2,000)$ and $\mbox{Q}_{4\mbox{K}}=(720,000\pm 10,000)$respectively, the latter corresponding to a gain of one order of magnitude with respect to a traditional copper cylindrical-cavity with the corresponding TM$_{010}$ mode resonating at the same frequency. The implications to dark-matter axion-searches with cavity experiments are discussed showing that the gain in quality factor is not spoiled by a reduced geometrical coupling $C_{030}$ of the cavity mode to the axion field. This reduction effect is estimated to be at most 20%. Numerical simulations show that frequency tuning of several hundreds MHz is feasible.
△ Less
Submitted 28 September, 2020; v1 submitted 6 April, 2020;
originally announced April 2020.
-
High quality factor photonic cavity for dark matter axion searches
Authors:
D. Alesini,
C. Braggio,
G. Carugno,
N. Crescini,
D. D'Agostino,
D. Di Gioacchino,
R. Di Vora,
P. Falferi,
U. Gambardella,
C. Gatti,
G. Iannone,
C. Ligi,
A. Lombardi,
G. Maccarrone,
A. Ortolan,
R. Pengo,
C. Pira,
A. Rettaroli,
G. Ruoso,
L. Taffarello,
S. Tocci
Abstract:
Searches for dark matter axion involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, however, by the presence of the external magnetic field. In this paper we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic stru…
▽ More
Searches for dark matter axion involve the use of microwave resonant cavities operating in a strong magnetic field. Detector sensitivity is directly related to the cavity quality factor, which is limited, however, by the presence of the external magnetic field. In this paper we present a cavity of novel design whose quality factor is not affected by a magnetic field. It is based on a photonic structure by the use of sapphire rods. The quality factor at cryogenic temperature is in excess of $5 \times 10^5$ for a selected mode.
△ Less
Submitted 5 February, 2020;
originally announced February 2020.