The Electric Field Dependence of Single Electron Emission in the PIXeY Two-Phase Xenon Detector
Authors:
E. Bodnia,
E. P. Bernard,
A. Biekert,
E. M. Boulton,
S. B. Cahn,
N. Destefano,
B. N. V. Edwards,
M. Gai,
M. Horn,
N. A. Larsen,
Q. Riffard,
B. Tennyson,
V. Velan,
C. Wahl,
D. N. McKinsey
Abstract:
Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events a…
▽ More
Dual phase xenon detectors are widely used in experimental searches for galactic darkmatter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. In this paper, we describe single electron backgrounds in ${}^{83m}Kr$ calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by the Fowler-Nordheim (FN) effect is measured, and its electric field dependence is quantified. The photoionization of grids and impurities by prompt scintillation and proportional scintillation also contributes to the single electron background.
△ Less
Submitted 16 December, 2021; v1 submitted 10 January, 2021;
originally announced January 2021.
Extraction efficiency of drifting electrons in a two-phase xenon time projection chamber
Authors:
B. N. V. Edwards,
E. Bernard,
E. M. Boulton,
N. Destefano,
M. Gai,
M. Horn,
N. Larsen,
B. Tennyson,
L. Tvrznikova,
C. Wahl,
D. N. McKinsey
Abstract:
We present a measurement of the extraction efficiency of quasi-free electrons from the liquid into the gas phase in a two-phase xenon time-projection chamber. The measurements span a range of electric fields from 2.4 to 7.1 kV/cm in the liquid xenon, corresponding to 4.5 to 13.1 kV/cm in the gaseous xenon. Extraction efficiency continues to increase at the highest extraction fields, implying that…
▽ More
We present a measurement of the extraction efficiency of quasi-free electrons from the liquid into the gas phase in a two-phase xenon time-projection chamber. The measurements span a range of electric fields from 2.4 to 7.1 kV/cm in the liquid xenon, corresponding to 4.5 to 13.1 kV/cm in the gaseous xenon. Extraction efficiency continues to increase at the highest extraction fields, implying that additional charge signal may be attained in two-phase xenon detectors through careful high-voltage engineering of the gate-anode region.
△ Less
Submitted 7 January, 2018; v1 submitted 30 October, 2017;
originally announced October 2017.