-
QSHS: An Axion Dark Matter Resonant Search Apparatus
Authors:
A. Alsulami,
I. Bailey,
G. Carosi,
G. Chapman,
B. Chakraborty,
E. J. Daw,
N. Du,
S. Durham,
J. Esmenda,
J. Gallop,
T. Gamble,
T. Godfrey,
G. Gregori,
J. Halliday,
L. Hao,
E. Hardy,
E. A. Laird,
P. Leek,
J. March-Russell,
P. J. Meeson,
C. F. Mostyn,
Yu. A. Pashkin,
S. O. Peatain,
M. Perry,
M. Piscitelli
, et al. (10 additional authors not shown)
Abstract:
We describe a resonant cavity search apparatus for axion dark matter constructed by the Quantum Sensors for the Hidden Sector (QSHS) collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles (ALPs), dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cav…
▽ More
We describe a resonant cavity search apparatus for axion dark matter constructed by the Quantum Sensors for the Hidden Sector (QSHS) collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles (ALPs), dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator and threaded by a solenoidal magnetic field, nominally 8T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range $\rm 2.0$ to $\rm 40\,eV/c^2$. We present performance data for the resonator, dilution refrigerator, and magnet, and plans for the first science run.
△ Less
Submitted 16 April, 2025;
originally announced April 2025.
-
Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX
Authors:
ADMX Collaboration,
G. Carosi,
C. Cisneros,
N. Du,
S. Durham,
N. Robertson,
C. Goodman,
M. Guzzetti,
C. Hanretty,
K. Enzian,
L. J Rosenberg,
G. Rybka,
J. Sinnis,
D. Zhang,
John Clarke,
I. Siddiqi,
A. S. Chou,
M. Hollister,
A. Sonnenschein,
S. Knirck,
T. J. Caligiure,
J. R. Gleason,
A. T. Hipp,
P. Sikivie,
M. E. Solano
, et al. (28 additional authors not shown)
Abstract:
Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong CP problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX…
▽ More
Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong CP problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10-1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov (KSVZ) sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.
△ Less
Submitted 9 April, 2025;
originally announced April 2025.
-
Improved Receiver Noise Calibration for ADMX Axion Search: 4.54 to 5.41 $μ$eV
Authors:
M. Guzzetti,
D. Zhang,
C. Goodman,
C. Hanretty,
J. Sinnis,
L. J Rosenberg,
G. Rybka,
John Clarke,
I. Siddiqi,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
T. J. Caligiure,
J. R. Gleason,
A. T. Hipp,
P. Sikivie,
M. E. Solano,
N. S. Sullivan,
D. B. Tanner,
R. Khatiwada,
G. Carosi,
N. Du,
C. Cisneros,
N. Robertson
, et al. (26 additional authors not shown)
Abstract:
Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Due to the weak coupling of axions to photons however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant en…
▽ More
Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Due to the weak coupling of axions to photons however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra low-noise electronics. In this paper we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280~MHz taken during ADMX's most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and JPA, as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.
△ Less
Submitted 13 March, 2025; v1 submitted 11 November, 2024;
originally announced November 2024.
-
Axion Dark Matter eXperiment around 3.3 μeV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability
Authors:
C. Goodman,
M. Guzzetti,
C. Hanretty,
L. J. Rosenberg,
G. Rybka,
J. Sinnis,
D. Zhang,
John Clarke,
I. Siddiqi,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
T. J. Caligiure,
J. R. Gleason,
A. T. Hipp,
P. Sikivie,
M. E. Solano,
N. S. Sullivan,
D. B. Tanner,
R. Khatiwada,
G. Carosi,
C. Cisneros,
N. Du,
N. Robertson
, et al. (24 additional authors not shown)
Abstract:
We report the results of a QCD axion dark matter search with discovery ability for Dine Fischler Srednicki Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultra low-noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 $μ$eV, assuming…
▽ More
We report the results of a QCD axion dark matter search with discovery ability for Dine Fischler Srednicki Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultra low-noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 $μ$eV, assuming a standard halo model with a local energy density of 0.45 GeV/cm$^3$ made up 100% of axions.
△ Less
Submitted 2 May, 2025; v1 submitted 27 August, 2024;
originally announced August 2024.
-
Axion Dark Matter eXperiment: Run 1A Analysis Details
Authors:
C. Boutan,
B. H. LaRoque,
E. Lentz,
N. S. Oblath,
M. S. Taubman,
J. Tedeschi,
J. Yang,
A. M. Jones,
T. Braine,
N. Crisosto,
L. J Rosenberg,
G. Rybka,
D. Will,
D. Zhang,
S. Kimes,
R. Ottens,
C. Bartram,
D. Bowring,
R. Cervantes,
A. S. Chou,
S. Knirck,
D. V. Mitchell,
A. Sonnenschein,
W. Wester,
R. Khatiwada
, et al. (28 additional authors not shown)
Abstract:
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower…
▽ More
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Low Frequency (100-600 MHz) Searches with Axion Cavity Haloscopes
Authors:
S. Chakrabarty,
J. R. Gleason,
Y. Han,
A. T. Hipp,
M. Solano,
P. Sikivie,
N. S. Sullivan,
D. B. Tanner,
M. Goryachev,
E. Hartman,
B. T. McAllister,
A. Quiskamp,
C. Thomson,
M. E. Tobar,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
T. Braine,
M. Guzzetti,
C. Hanretty,
G. Leum,
L. J Rosenberg
, et al. (22 additional authors not shown)
Abstract:
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and…
▽ More
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab.
△ Less
Submitted 28 March, 2023; v1 submitted 7 March, 2023;
originally announced March 2023.
-
Search for a dark-matter induced Cosmic Axion Background with ADMX
Authors:
ADMX Collaboration,
T. Nitta,
T. Braine,
N. Du,
M. Guzzetti,
C. Hanretty,
G. Leum,
L. J Rosenberg,
G. Rybka,
J. Sinnis,
John Clarke,
I. Siddiqi,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason,
A. T. Hipp,
P. Sikivie,
N. S. Sullivan,
D. B. Tanner,
R. Khatiwada,
G. Carosi
, et al. (23 additional authors not shown)
Abstract:
We report the first result of a direct search for a Cosmic ${\it axion}$ Background (C$a$B) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the C$a$B will be broad. We introduce a novel analys…
▽ More
We report the first result of a direct search for a Cosmic ${\it axion}$ Background (C$a$B) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the C$a$B will be broad. We introduce a novel analysis strategy, which searches for a C$a$B induced daily modulation in the power measured by the haloscope. Using this, we repurpose data collected to search for dark matter to set a limit on the axion photon coupling of a C$a$B originating from dark matter cascade decay via a mediator in the 800-995 MHz frequency range. We find that the present sensitivity is limited by fluctuations in the cavity readout as the instrument scans across dark matter masses. Nevertheless, we suggest that these challenges can be surmounted using superconducting qubits as single photon counters, and allow ADMX to operate as a telescope searching for axions emerging from the decay of dark matter. The daily modulation analysis technique we introduce can be deployed for various broadband RF signals, such as other forms of a C$a$B or even high-frequency gravitational waves.
△ Less
Submitted 3 October, 2023; v1 submitted 10 March, 2023;
originally announced March 2023.
-
Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier
Authors:
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason,
A. T. Hipp,
S. Jois,
P. Sikivie
, et al. (26 additional authors not shown)
Abstract:
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search.…
▽ More
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search. The JTWPA was operated in the insert of the Axion Dark Matter eXperiment (ADMX) as part of an independent receiver chain that was attached to a 0.588-liter cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
△ Less
Submitted 15 October, 2021;
originally announced October 2021.
-
Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~μ$eV Mass Range
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
E. Burns,
R. Cervantes,
N. Crisosto,
N. Du,
H. Korandla,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason
, et al. (27 additional authors not shown)
Abstract:
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temp…
▽ More
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.
△ Less
Submitted 29 December, 2021; v1 submitted 12 October, 2021;
originally announced October 2021.
-
Axion Dark Matter eXperiment: Detailed Design and Operations
Authors:
R. Khatiwada,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
D. V. Mitchell,
T. Braine,
C. Bartram,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Will,
G. Carosi,
N. Woollett,
S. Durham,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath
, et al. (26 additional authors not shown)
Abstract:
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technolog…
▽ More
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as state-of-the-art quantum limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable Microstrip Superconducting Quantum Interference Device (SQUID) Amplifier (MSA), in Run 1A, and a Josephson Parametric Amplifier (JPA), in Run 1B, along with novel analysis tools that characterize the system noise temperature.
△ Less
Submitted 30 September, 2020;
originally announced October 2020.
-
Extended Search for the Invisible Axion with the Axion Dark Matter Experiment
Authors:
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
M. S. Taubman,
J. Clarke,
A. Dove,
A. Eddins
, et al. (17 additional authors not shown)
Abstract:
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode c…
▽ More
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode crossings using an alternate cavity configuration. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first stage signal amplifier.
△ Less
Submitted 1 November, 2019; v1 submitted 18 October, 2019;
originally announced October 2019.
-
Piezoelectrically Tuned Multimode Cavity Search for Axion Dark Matter
Authors:
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
R. Cervantes,
N. Du,
N. Force,
S. Kimes,
R. Ottens,
L. J. Rosenberg,
G. Rybka,
J. Yang,
G. Carosi,
N. Woollett,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
R. Bradley,
E. J. Daw,
A. Agrawal,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley
, et al. (9 additional authors not shown)
Abstract:
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, highe…
▽ More
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM$_{010}$ and TM$_{020}$ modes.
△ Less
Submitted 3 January, 2019;
originally announced January 2019.
-
A Search for Halo Axions
Authors:
Edward J. Daw
Abstract:
The axion is an unusually well motivated dark matter candidate which is the Goldstone Boson associated with spontaneous breaking of the PQ symmetry of QCD. I describe an experiment to search for axions in our Galactic halo using a high Q resonant cavity coupled to ultra-low-noise receiver electronics. I discuss the analysis of the first production data and present the first results of the experime…
▽ More
The axion is an unusually well motivated dark matter candidate which is the Goldstone Boson associated with spontaneous breaking of the PQ symmetry of QCD. I describe an experiment to search for axions in our Galactic halo using a high Q resonant cavity coupled to ultra-low-noise receiver electronics. I discuss the analysis of the first production data and present the first results of the experiment. At 90\% confidence KSVZ axions of mass 2.9 to 3.3 micro eV are excluded as the dark matter in the halo of our Galaxy.
This thesis was submitted in 1997 at MIT. It has been used as a reference in many subsequent axion experiments, and it has been suggested that it should be placed on the archive as a reference and a resource. I am complying with this request.
△ Less
Submitted 31 December, 2022; v1 submitted 24 July, 2018;
originally announced July 2018.
-
Resonant feedback for axion and hidden sector dark matter searches
Authors:
Edward J. Daw
Abstract:
Resonant feedback circuits are proposed as an alternative to normal modes of conducting wall cavities or lumped circuits in searches for hidden sector particles. The proposed method offers several potential advantages over the most sensitive axion searches to date, that employ cavity resonators, including coverage of a wider range of axion masses, the ability to probe many axion masses simultaneou…
▽ More
Resonant feedback circuits are proposed as an alternative to normal modes of conducting wall cavities or lumped circuits in searches for hidden sector particles. The proposed method offers several potential advantages over the most sensitive axion searches to date, that employ cavity resonators, including coverage of a wider range of axion masses, the ability to probe many axion masses simultaneously, and the elimination of experimentally troublesome mechanical tuning rod mechanisms. After an outline of the proposed method, we present a noise budget for a straw-man experiment configuration. We show that the proposed experiment has the potential to probe the axion mass range 2-40 micro-eV with 38 days of integration time. Other existing and proposed resonant searches for hidden sector particles may also benefit from this approach to detection.
△ Less
Submitted 2 November, 2018; v1 submitted 29 May, 2018;
originally announced May 2018.
-
A Search for Invisible Axion Dark Matter with the Axion Dark Matter Experiment
Authors:
N. Du,
N. Force,
R. Khatiwada,
E. Lentz,
R. Ottens,
L. J Rosenberg,
G. Rybka,
G. Carosi,
N. Woolett,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
C. Boutan,
N. S. Oblath,
R. Bradley,
E. J. Daw,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley,
N. Crisosto,
J. R. Gleason,
S. Jois,
P. Sikivie,
I. Stern
, et al. (3 additional authors not shown)
Abstract:
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from t…
▽ More
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultra-low-noise SQUID amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses.
△ Less
Submitted 17 April, 2018; v1 submitted 16 April, 2018;
originally announced April 2018.
-
Measurement of directional range components of nuclear recoil tracks in a fiducialised dark matter detector
Authors:
J. B. R. Battat,
E. J. Daw,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. R. Lee,
D. Loomba,
W. Lynch,
E. H. Miller,
F. Mouton,
S. Paling,
N. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner
Abstract:
We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this measurement, neutron-i…
▽ More
We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this measurement, neutron-induced nuclear recoil tracks were generated by exposing the detector to $^{252}$Cf source from different directions. Using these events, the sensitivity of the detector to the expected axial directional signatures were investigated as the neutron source was moved from one detector axis to another. Results obtained from these measurements show clear sensitivity of the DRIFT detector to the axial directional signatures in this fiducialization gas mode.
△ Less
Submitted 28 July, 2017;
originally announced July 2017.
-
First measurement of nuclear recoil head-tail sense in a fiducialised WIMP dark matter detector
Authors:
J. B. R. Battat,
E. Daw,
A. C. Ezeribe,
J. -L. Gauvreau,
J. L. Harton,
R. Lafler,
E. R. Lee,
D. Loomba,
A. Lumnah,
E. H. Miller,
F. Mouton,
A. StJ. Murphy,
S. M. Paling,
N. S. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. G. Schuckman II,
D. P. Snowden-Ifft,
N. J. C. Spooner
Abstract:
Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time proj…
▽ More
Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time projection chamber. In this new operational mode, the distance between each event vertex and the readout plane is determined by the measurement of minority carriers produced by adding a small amount of oxygen to the nominal CS$_{2}$ + CF$_{4}$ target gas mixture. The CS$_2$ + CF$_4$ + O$_2$ mixture has been shown to enable background-free operation at current sensitivities. Sulfur, fluorine, and carbon recoils were generated using neutrons emitted from a $^{252}$Cf source positioned at different locations around the detector. Measurement of the relative energy loss along the recoil tracks allowed the track vector sense, or the so-called head-tail asymmetry parameter, to be deduced. Results show that the previously reported observation of head-tail sensitivity in pure CS$_{2}$ is well retained after the addition of oxygen to the gas mixture.
△ Less
Submitted 24 November, 2016; v1 submitted 16 June, 2016;
originally announced June 2016.
-
First background-free limit from a directional dark matter experiment: results from a fully fiducialised DRIFT detector
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. -L. Gauvreau,
M. Gold,
J. L. Harton,
J. M. Landers,
E. Law,
E. R. Lee,
D. Loomba,
A. Lumnah,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
F. Mouton,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Robinson,
S. W. Sadler,
A. Scarff,
F. Schuckman,
D. P. Snowden-Ifft
, et al. (6 additional authors not shown)
Abstract:
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present re…
▽ More
The addition of O2 to gas mixtures in time projection chambers containing CS2 has recently been shown to produce multiple negative ions that travel at slightly different velocities. This allows a measurement of the absolute position of ionising events in the z (drift) direction. In this work, we apply the z-fiducialisation technique to a directional dark matter search. In particular, we present results from a 46.3 live-day source-free exposure of the DRIFT-IId detector run in this completely new mode. With full-volume fiducialisation, we have achieved the first background-free operation of a directional detector. The resulting exclusion curve for spin-dependent WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better than our previous work. We describe the automated analysis used here, and argue that detector upgrades, implemented after the acquisition of these data, will bring an additional factor of >3 improvement in the near future.
△ Less
Submitted 23 July, 2015; v1 submitted 28 October, 2014;
originally announced October 2014.
-
Radon in the DRIFT-II directional dark matter TPC: emanation, detection and mitigation
Authors:
J. B. R. Battat,
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. L. Harton,
J. M. Landers,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. W. Sadler,
A. Scarff,
D. P. Snowden-Ifft,
N. J. C. Spooner
, et al. (4 additional authors not shown)
Abstract:
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes…
▽ More
Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils of radon daughter isotopes, which can mimic the signal expected from WIMP interactions. Presented here are results of measurements of radon emanation from detector materials in the 1 metre cubed DRIFT-II directional dark matter gas time projection chamber experiment. Construction and operation of a radon emanation facility for this work is described, along with an analysis to continuously monitor DRIFT data for the presence of internal 222Rn and 218Po. Applying this analysis to historical DRIFT data, we show how systematic substitution of detector materials for alternatives, selected by this device for low radon emanation, has resulted in a factor of ~10 reduction in internal radon rates. Levels are found to be consistent with the sum from separate radon emanation measurements of the internal materials and also with direct measurement using an attached alpha spectrometer. The current DRIFT detector, DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 μBq/l with current analysis efficiency, potentially opening up DRIFT technology as a new tool for sensitive radon assay of materials.
△ Less
Submitted 25 August, 2014; v1 submitted 15 July, 2014;
originally announced July 2014.
-
Background Assay and Rejection in DRIFT
Authors:
Jeff Brack,
Ed Daw,
Alexei Dorofeev,
Anthony Ezeribe,
Jean-Luc Gauvreau,
Michael Gold,
John Harton,
Randy Lafler,
Robert Lauer,
Eric R. Lee,
Dinesh Loomba,
John Matthews,
Eric H. Miller,
Alissa Monte,
Alex Murphy,
Sean Paling,
Nguyen Phan,
Steve Sadler,
Andrew Scarff,
Daniel Snowden-Ifft,
Neil Spooner,
Sam Telfer,
Daniel Walker,
Matt Williams,
Leonid Yuriev
Abstract:
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce these backgrounds led to replacing the 20 μm wire central cathode with one constructed from 0.9 μm aluminized mylar, which is almost totally transparent to alp…
▽ More
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with directional sensitivity to WIMP-induced nuclear recoils. Its primary backgrounds were due to alpha decays from contamination on the central cathode. Efforts to reduce these backgrounds led to replacing the 20 μm wire central cathode with one constructed from 0.9 μm aluminized mylar, which is almost totally transparent to alpha particles. Detailed modeling of the nature and origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of alpha decay backgrounds from the central cathode. This led to further improvements in the thin-film cathode resulting in over 2 orders of magnitude reduction in backgrounds compared to the wire cathode. Finally, the addition of O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative charge carriers, providing a method to determine the absolute position of nuclear recoils and reject all known remaining backgrounds while retaining a high efficiency for nuclear recoil detection.
△ Less
Submitted 8 April, 2014;
originally announced April 2014.
-
Long-term study of backgrounds in the DRIFT-II directional dark matter experiment
Authors:
J. Brack,
E. Daw,
A. Dorofeev,
A. C. Ezeribe,
J. R. Fox,
J. -L. Gauvreau,
M. Gold,
L. J. Harmon,
J. Harton,
R. Lafler,
J. M. Landers,
R. Lauer,
E. R. Lee,
D. Loomba,
J. A. J. Matthews,
E. H. Miller,
A. Monte,
A. StJ. Murphy,
S. M. Paling,
N. Phan,
M. Pipe,
M. Robinson,
S. Sadler,
A. Scarff,
D. P. Snowden-Ifft
, et al. (4 additional authors not shown)
Abstract:
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from t…
▽ More
Low-pressure gas Time Projection Chambers being developed for directional dark matter searches offer a technology with strong particle identification capability combined with the potential to produce a definitive detection of Galactic Weakly Interacting Massive Particle (WIMP) dark matter. A source of events able to mimic genuine WIMP-induced nuclear recoil tracks arises in such experiments from the decay of radon gas inside the vacuum vessel. The recoils that result from associated daughter nuclei are termed Radon Progeny Recoils (RPRs). We present here experimental data from a long-term study using the DRIFT-II directional dark matter experiment at the Boulby Underground Laboratory of the RPRs, and other backgrounds that are revealed by relaxing the normal cuts that are applied to WIMP search data. By detailed examination of event classes in both spatial and time coordinates using 5.5 years of data, we demonstrate the ability to determine the origin of 4 specific background populations and describe development of new technology and mitigation strategies to suppress them.
△ Less
Submitted 12 May, 2014; v1 submitted 21 July, 2013;
originally announced July 2013.
-
The DRIFT Dark Matter Experiments
Authors:
E. Daw,
A. Dorofeev,
J. R. Fox,
J. -L. Gauvreau,
C. Ghag,
L. J. Harmon,
J. L. Harton,
M. Gold,
E. R. Lee,
D. Loomba,
E. H. Miller,
A. St. J. Murphy,
S. M. Paling,
J. M. Landers,
N. Phan,
M. Pipe,
K. Pushkin,
M. Robinson,
S. W. Sadler,
D. P. Snowden-Ifft,
N. J. C. Spooner,
D. Walker,
D. Warner
Abstract:
The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale directional Dark M…
▽ More
The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale directional Dark Matter detector.
△ Less
Submitted 2 October, 2011;
originally announced October 2011.
-
The ArDM experiment
Authors:
ArDM Collaboration,
C. Amsler,
A. Badertscher,
V. Boccone,
N. Bourgeois,
A. Bueno,
M. C. Carmona-Benitez,
M. Chorowski,
W. Creus,
A. Curioni,
E. Daw,
U. Degunda,
A. Dell'Antone,
M. Droge,
L. Epprecht,
C. Haller,
M. Haranczyk,
S. Horikawa,
L. Kaufmann,
J. Kisiel,
L. Knecht,
M. Laffranchi,
J. Lagoda,
C. Lazzaro,
P. Lightfoot
, et al. (29 additional authors not shown)
Abstract:
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, includin…
▽ More
The aim of the ArDM project is the development and operation of a one ton double-phase liquid argon detector for direct Dark Matter searches. The detector measures both the scintillation light and the ionization charge from ionizing radiation using two independent readout systems. This paper briefly describes the detector concept and presents preliminary results from the ArDM R&D program, including a 3 l prototype developed to test the charge readout system.
△ Less
Submitted 28 June, 2010;
originally announced June 2010.
-
Low Energy Electron and Nuclear Recoil Thresholds in the DRIFT-II Negative Ion TPC for Dark Matter Searches
Authors:
S. Burgos,
E. Daw,
J. Forbes,
C. Ghag,
M. Gold,
C. Hagemann,
V. A. Kudryavtsev,
T. B. Lawson,
D. Loomba,
P. Majewski,
D. Muna,
A. St. J. Murphy,
S. M. Paling,
A. Petkov,
S. J. S. Plank,
M. Robinson,
N. Sanghi,
D. P. Snowden-Ifft,
N. J. C. Spooner,
J. Turk,
E. Tziaferi
Abstract:
Understanding the ability to measure and discriminate particle events at the lowest possible energy is an essential requirement in developing new experiments to search for weakly interacting massive particle (WIMP) dark matter. In this paper we detail an assessment of the potential sensitivity below 10 keV in the 1 m^3 DRIFT-II directionally sensitive, low pressure, negative ion time projection…
▽ More
Understanding the ability to measure and discriminate particle events at the lowest possible energy is an essential requirement in developing new experiments to search for weakly interacting massive particle (WIMP) dark matter. In this paper we detail an assessment of the potential sensitivity below 10 keV in the 1 m^3 DRIFT-II directionally sensitive, low pressure, negative ion time projection chamber (NITPC), based on event-by-event track reconstruction and calorimetry in the multiwire proportional chamber (MWPC) readout. By application of a digital smoothing polynomial it is shown that the detector is sensitive to sulfur and carbon recoils down to 2.9 and 1.9 keV respectively, and 1.2 keV for electron induced events. The energy sensitivity is demonstrated through the 5.9 keV gamma spectrum of 55Fe, where the energy resolution is sufficient to identify the escape peak. The effect a lower energy sensitivity on the WIMP exclusion limit is demonstrated. In addition to recoil direction reconstruction for WIMP searches this sensitivity suggests new prospects for applications also in KK axion searches.
△ Less
Submitted 30 March, 2009; v1 submitted 2 March, 2009;
originally announced March 2009.
-
Measurement of the Range Component Directional Signature in a DRIFT-II Detector using 252Cf Neutrons
Authors:
S. Burgos,
E. Daw,
J. Forbes,
C. Ghag,
M. Gold,
C. Hagemann,
V. A. Kudryavtsev,
T. B. Lawson,
D. Loomba,
P. Majewski,
D. Muna,
A. St. J. Murphy,
G. G. Nicklin,
S. M. Paling,
A. Petkov,
S. J. S. Plank,
M. Robinson,
N. Sanghi,
D. P. Snowden-Ifft,
N. J. C. Spooner,
J. Turk,
E. Tziaferi
Abstract:
The DRIFT collaboration utilizes low pressure gaseous detectors to search for WIMP dark matter with directional signatures. A 252Cf neutron source was placed on each of the principal axes of a DRIFT detector in order to test its ability to measure directional signatures from the three components of very low energy (~keV/amu) recoil ranges. A high trigger threshold and the event selection procedu…
▽ More
The DRIFT collaboration utilizes low pressure gaseous detectors to search for WIMP dark matter with directional signatures. A 252Cf neutron source was placed on each of the principal axes of a DRIFT detector in order to test its ability to measure directional signatures from the three components of very low energy (~keV/amu) recoil ranges. A high trigger threshold and the event selection procedure ensured that only sulfur recoils were analyzed. Sulfur recoils produced in the CS2 target gas by the 252Cf source closely match those expected from massive WIMP induced sulfur recoils. For each orientation of the source a directional signal from the range components was observed, indicating that the detector is directional along all 3 axes. An analysis of these results yields an optimal orientation for DRIFT detectors when searching for a directional signature from WIMPs. Additional energy dependent information is provided to aid in understanding this effect.
△ Less
Submitted 24 July, 2008;
originally announced July 2008.
-
Measurements of neutrons produced by high-energy muons at the Boulby Underground Laboratory
Authors:
H. M. Araujo,
J. Blockley,
C. Bungau,
M. J. Carson,
H. Chagani,
E. Daw,
B. Edwards,
C. Ghag,
E. V. Korolkova,
V. A. Kudryavtsev,
P. K. Lightfoot,
A. Lindote,
I. Liubarsky,
R. Luscher,
P. Majewski,
K. Mavrokoridis,
J. E. McMillan,
A. St. J. Murphy,
S. M. Paling,
J. Pinto da Cunha,
R. M. Preece,
M. Robinson,
N. J. T. Smith,
P. F. Smith,
N. J. C. Spooner
, et al. (4 additional authors not shown)
Abstract:
We present the first measurements of the muon-induced neutron flux at the Boulby Underground Laboratory. The experiment was carried out with an 0.73 tonne liquid scintillator that also served as an anticoincidence system for the ZEPLIN-II direct dark matter search. The experimental method exploited the delayed coincidences between high-energy muon signals and gamma-rays from radiative neutron ca…
▽ More
We present the first measurements of the muon-induced neutron flux at the Boulby Underground Laboratory. The experiment was carried out with an 0.73 tonne liquid scintillator that also served as an anticoincidence system for the ZEPLIN-II direct dark matter search. The experimental method exploited the delayed coincidences between high-energy muon signals and gamma-rays from radiative neutron capture on hydrogen or other elements. The muon-induced neutron rate, defined as the average number of detected neutrons per detected muon, was measured as $0.079 \pm 0.003$ (stat.) neutrons/muon using neutron-capture signals above 0.55 MeV in a time window of 40-190 $μ$s after the muon trigger. Accurate Monte Carlo simulations of the neutron production, transport and detection in a precisely modeled laboratory and experimental setup using the GEANT4 toolkit gave a result 1.8 times higher than the measured value. The difference greatly exceeds all statistical and systematic uncertainties. As the vast majority of neutrons detected in the current setup were produced in lead we evaluated from our measurements the neutron yield in lead as $(1.31 \pm 0.06) \times 10^{-3}$ neutrons/muon/(g/cm$^2$) for a mean muon energy of about 260 GeV.
△ Less
Submitted 20 May, 2008;
originally announced May 2008.
-
Simulations of neutron background in a time projection chamber relevant to dark matter searches
Authors:
M. J. Carson,
J. C. Davies,
E. Daw,
R. J. Hollingworth,
J. A. Kirkpatrick,
V. A. Kudryavtsev,
T. B. Lawson,
P. K. Lightfoot,
J. E. McMillan,
B. Morgan,
S. M. Paling,
M. Robinson,
N. J. C Spooner,
D. R. Tovey,
E. Tziaferi
Abstract:
Presented here are results of simulations of neutron background performed for a time projection chamber acting as a particle dark matter detector in an underground laboratory. The investigated background includes neutrons from rock and detector components, generated via spontaneous fission and (alpha, n) reactions, as well as those due to cosmic-ray muons. Neutrons were propagated to the sensiti…
▽ More
Presented here are results of simulations of neutron background performed for a time projection chamber acting as a particle dark matter detector in an underground laboratory. The investigated background includes neutrons from rock and detector components, generated via spontaneous fission and (alpha, n) reactions, as well as those due to cosmic-ray muons. Neutrons were propagated to the sensitive volume of the detector and the nuclear recoil spectra were calculated. Methods of neutron background suppression were also examined and limitations to the sensitivity of a gaseous dark matter detector are discussed. Results indicate that neutrons should not limit sensitivity to WIMP-nucleon interactions down to a level of (1 - 3) x 10^{-8} pb in a 10 kg detector.
△ Less
Submitted 9 March, 2005;
originally announced March 2005.
-
Neutron background in large-scale xenon detectors for dark matter searches
Authors:
M. J. Carson,
J. C. Davies,
E. Daw,
R. J. Hollingworth,
V. A. Kudryavtsev,
T. B. Lawson,
P. K. Lightfoot,
J. E. McMillan,
B. Morgan,
S. M. Paling,
M. Robinson,
N. J. C. Spooner,
D. R. Tovey
Abstract:
Simulations of the neutron background for future large-scale particle dark matter detectors are presented. Neutrons were generated in rock and detector elements via spontaneous fission and (alpha,n) reactions, and by cosmic-ray muons. The simulation techniques and results are discussed in the context of the expected sensitivity of a generic liquid xenon dark matter detector. Methods of neutron b…
▽ More
Simulations of the neutron background for future large-scale particle dark matter detectors are presented. Neutrons were generated in rock and detector elements via spontaneous fission and (alpha,n) reactions, and by cosmic-ray muons. The simulation techniques and results are discussed in the context of the expected sensitivity of a generic liquid xenon dark matter detector. Methods of neutron background suppression are investigated. A sensitivity of $10^{-9}-10^{-10}$ pb to WIMP-nucleon interactions can be achieved by a tonne-scale detector.
△ Less
Submitted 30 April, 2004;
originally announced April 2004.
-
A Radio Telescope Search for Axions
Authors:
B. D. Blout,
E. J. Daw,
M. P. Decowski,
Paul T. P. Ho,
L. J Rosenberg,
D. B. Yu
Abstract:
The axion is a hypothetical elementary particle and a cold dark matter candidate. It could dominate potential wells of most astrophysical objects. Axions spontaneously decay into nearly monochromatic microwave photons. We present results from a radio telescope search for these axion decay photons of mass between 298 and 363 micro-eV in Local Group dwarf galaxies. We report a limit on the axion-t…
▽ More
The axion is a hypothetical elementary particle and a cold dark matter candidate. It could dominate potential wells of most astrophysical objects. Axions spontaneously decay into nearly monochromatic microwave photons. We present results from a radio telescope search for these axion decay photons of mass between 298 and 363 micro-eV in Local Group dwarf galaxies. We report a limit on the axion-to-two-photon coupling constant g > 1.0 x 10^(-9) GeV^(-1).
△ Less
Submitted 21 June, 2000;
originally announced June 2000.