-
Noise limits for dc SQUID readout of high-$Q$ resonators below 300 MHz
Authors:
V. Ankel,
C. Bartram,
J. Begin,
C. Bell,
L. Brouwer,
S. Chaudhuri,
John Clarke,
H. -M. Cho,
J. Corbin,
W. Craddock,
S. Cuadra,
A. Droster,
M. Durkin,
J. Echevers,
J. T. Fry,
G. Hilton,
K. D. Irwin,
A. Keller,
R. Kolevatov,
A. Kunder,
D. Li,
N. Otto,
K. M. W. Pappas,
N. M. Rapidis,
C. P. Salemi
, et al. (16 additional authors not shown)
Abstract:
We present the limits on noise for the readout of cryogenic high-$Q$ resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche-Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array des…
▽ More
We present the limits on noise for the readout of cryogenic high-$Q$ resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche-Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-$Q$ resonator over this frequency range, and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction-imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m$^3$ axion search, which will use dc SQUIDs in this frequency range.
△ Less
Submitted 28 April, 2025;
originally announced April 2025.
-
Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX
Authors:
ADMX Collaboration,
G. Carosi,
C. Cisneros,
N. Du,
S. Durham,
N. Robertson,
C. Goodman,
M. Guzzetti,
C. Hanretty,
K. Enzian,
L. J Rosenberg,
G. Rybka,
J. Sinnis,
D. Zhang,
John Clarke,
I. Siddiqi,
A. S. Chou,
M. Hollister,
A. Sonnenschein,
S. Knirck,
T. J. Caligiure,
J. R. Gleason,
A. T. Hipp,
P. Sikivie,
M. E. Solano
, et al. (28 additional authors not shown)
Abstract:
Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong CP problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX…
▽ More
Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong CP problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10-1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov (KSVZ) sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.
△ Less
Submitted 9 April, 2025;
originally announced April 2025.
-
Improved Receiver Noise Calibration for ADMX Axion Search: 4.54 to 5.41 $μ$eV
Authors:
M. Guzzetti,
D. Zhang,
C. Goodman,
C. Hanretty,
J. Sinnis,
L. J Rosenberg,
G. Rybka,
John Clarke,
I. Siddiqi,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
T. J. Caligiure,
J. R. Gleason,
A. T. Hipp,
P. Sikivie,
M. E. Solano,
N. S. Sullivan,
D. B. Tanner,
R. Khatiwada,
G. Carosi,
N. Du,
C. Cisneros,
N. Robertson
, et al. (26 additional authors not shown)
Abstract:
Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Due to the weak coupling of axions to photons however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant en…
▽ More
Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Due to the weak coupling of axions to photons however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra low-noise electronics. In this paper we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280~MHz taken during ADMX's most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and JPA, as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.
△ Less
Submitted 13 March, 2025; v1 submitted 11 November, 2024;
originally announced November 2024.
-
The ionization yield in a methane-filled spherical proportional counter
Authors:
M. M. Arora,
L. Balogh,
C. Beaufort,
A. Brossard,
M. Chapellier,
J. Clarke,
E. C. Corcoran,
J. -M. Coquillat,
A. Dastgheibi-Fard,
Y. Deng,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly,
P. Knights,
P. Lautridou,
A. Makowski
, et al. (18 additional authors not shown)
Abstract:
Spherical proportional counters (SPCs) are gaseous particle detectors sensitive to single ionization electrons in their target media, with large detector volumes and low background rates. The $\mbox{NEWS-G}$ collaboration employs this technology to search for low-mass dark matter, having previously performed searches with detectors at the Laboratoire Souterrain de Modane (LSM), including a recent…
▽ More
Spherical proportional counters (SPCs) are gaseous particle detectors sensitive to single ionization electrons in their target media, with large detector volumes and low background rates. The $\mbox{NEWS-G}$ collaboration employs this technology to search for low-mass dark matter, having previously performed searches with detectors at the Laboratoire Souterrain de Modane (LSM), including a recent campaign with a 135 cm diameter SPC filled with methane. While in situ calibrations of the detector response were carried out at the LSM, measurements of the mean ionization yield and fluctuations of methane gas in SPCs were performed using a 30 cm diameter detector. The results of multiple measurements taken at different operating voltages are presented. A UV laser system was used to measure the mean gas gain of the SPC, along with $\mathrm{^{37}Ar}$ and aluminum-fluorescence calibration sources. These measurements will inform the energy response model of future operating detectors.
△ Less
Submitted 11 April, 2025; v1 submitted 21 October, 2024;
originally announced October 2024.
-
Axion Dark Matter eXperiment around 3.3 μeV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability
Authors:
C. Goodman,
M. Guzzetti,
C. Hanretty,
L. J. Rosenberg,
G. Rybka,
J. Sinnis,
D. Zhang,
John Clarke,
I. Siddiqi,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
T. J. Caligiure,
J. R. Gleason,
A. T. Hipp,
P. Sikivie,
M. E. Solano,
N. S. Sullivan,
D. B. Tanner,
R. Khatiwada,
G. Carosi,
C. Cisneros,
N. Du,
N. Robertson
, et al. (24 additional authors not shown)
Abstract:
We report the results of a QCD axion dark matter search with discovery ability for Dine Fischler Srednicki Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultra low-noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 $μ$eV, assuming…
▽ More
We report the results of a QCD axion dark matter search with discovery ability for Dine Fischler Srednicki Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultra low-noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 $μ$eV, assuming a standard halo model with a local energy density of 0.45 GeV/cm$^3$ made up 100% of axions.
△ Less
Submitted 2 May, 2025; v1 submitted 27 August, 2024;
originally announced August 2024.
-
Search for Light Dark Matter with NEWS-G at the Laboratoire Souterrain de Modane Using a Methane Target
Authors:
M. M. Arora,
L. Balogh,
C. Beaufort,
A. Brossard,
M. Chapellier,
J. Clarke,
E. C. Corcoran,
J. -M. Coquillat,
A. Dastgheibi-Fard,
Y. Deng,
D. Durnford,
C. Garrah,
G. Gerbier,
I. Giomataris,
G. Giroux,
P. Gorel,
M. Gros,
P. Gros,
O. Guillaudin,
E. W. Hoppe,
I. Katsioulas,
F. Kelly,
P. Knights,
P. Lautridou,
A. Makowski
, et al. (18 additional authors not shown)
Abstract:
The NEWS-G direct detection experiment uses spherical proportional counters to search for light dark matter candidates. New results from a 10 day physics run with a $135\,\mathrm{cm}$ in diameter spherical proportional counter at the Laboratoire Souterrain de Modane are reported. The target consists of $114\,\mathrm{g}$ of methane, providing sensitivity to dark matter spin-dependent coupling to pr…
▽ More
The NEWS-G direct detection experiment uses spherical proportional counters to search for light dark matter candidates. New results from a 10 day physics run with a $135\,\mathrm{cm}$ in diameter spherical proportional counter at the Laboratoire Souterrain de Modane are reported. The target consists of $114\,\mathrm{g}$ of methane, providing sensitivity to dark matter spin-dependent coupling to protons. New constraints are presented in the mass range $0.17$ to $1.2\,\mathrm{GeV/c^2}$, with a 90% confidence level cross-section upper limit of $30.9\,\mathrm{pb}$ for a mass of $0.76\,\mathrm{GeV/c^2}$.
△ Less
Submitted 12 April, 2025; v1 submitted 17 July, 2024;
originally announced July 2024.
-
Axion Dark Matter eXperiment: Run 1A Analysis Details
Authors:
C. Boutan,
B. H. LaRoque,
E. Lentz,
N. S. Oblath,
M. S. Taubman,
J. Tedeschi,
J. Yang,
A. M. Jones,
T. Braine,
N. Crisosto,
L. J Rosenberg,
G. Rybka,
D. Will,
D. Zhang,
S. Kimes,
R. Ottens,
C. Bartram,
D. Bowring,
R. Cervantes,
A. S. Chou,
S. Knirck,
D. V. Mitchell,
A. Sonnenschein,
W. Wester,
R. Khatiwada
, et al. (28 additional authors not shown)
Abstract:
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower…
▽ More
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Low Frequency (100-600 MHz) Searches with Axion Cavity Haloscopes
Authors:
S. Chakrabarty,
J. R. Gleason,
Y. Han,
A. T. Hipp,
M. Solano,
P. Sikivie,
N. S. Sullivan,
D. B. Tanner,
M. Goryachev,
E. Hartman,
B. T. McAllister,
A. Quiskamp,
C. Thomson,
M. E. Tobar,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
T. Braine,
M. Guzzetti,
C. Hanretty,
G. Leum,
L. J Rosenberg
, et al. (22 additional authors not shown)
Abstract:
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and…
▽ More
We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab.
△ Less
Submitted 28 March, 2023; v1 submitted 7 March, 2023;
originally announced March 2023.
-
Search for a dark-matter induced Cosmic Axion Background with ADMX
Authors:
ADMX Collaboration,
T. Nitta,
T. Braine,
N. Du,
M. Guzzetti,
C. Hanretty,
G. Leum,
L. J Rosenberg,
G. Rybka,
J. Sinnis,
John Clarke,
I. Siddiqi,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason,
A. T. Hipp,
P. Sikivie,
N. S. Sullivan,
D. B. Tanner,
R. Khatiwada,
G. Carosi
, et al. (23 additional authors not shown)
Abstract:
We report the first result of a direct search for a Cosmic ${\it axion}$ Background (C$a$B) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the C$a$B will be broad. We introduce a novel analys…
▽ More
We report the first result of a direct search for a Cosmic ${\it axion}$ Background (C$a$B) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the C$a$B will be broad. We introduce a novel analysis strategy, which searches for a C$a$B induced daily modulation in the power measured by the haloscope. Using this, we repurpose data collected to search for dark matter to set a limit on the axion photon coupling of a C$a$B originating from dark matter cascade decay via a mediator in the 800-995 MHz frequency range. We find that the present sensitivity is limited by fluctuations in the cavity readout as the instrument scans across dark matter masses. Nevertheless, we suggest that these challenges can be surmounted using superconducting qubits as single photon counters, and allow ADMX to operate as a telescope searching for axions emerging from the decay of dark matter. The daily modulation analysis technique we introduce can be deployed for various broadband RF signals, such as other forms of a C$a$B or even high-frequency gravitational waves.
△ Less
Submitted 3 October, 2023; v1 submitted 10 March, 2023;
originally announced March 2023.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier
Authors:
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason,
A. T. Hipp,
S. Jois,
P. Sikivie
, et al. (26 additional authors not shown)
Abstract:
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search.…
▽ More
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search. The JTWPA was operated in the insert of the Axion Dark Matter eXperiment (ADMX) as part of an independent receiver chain that was attached to a 0.588-liter cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
△ Less
Submitted 15 October, 2021;
originally announced October 2021.
-
Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~μ$eV Mass Range
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
E. Burns,
R. Cervantes,
N. Crisosto,
N. Du,
H. Korandla,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason
, et al. (27 additional authors not shown)
Abstract:
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temp…
▽ More
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.
△ Less
Submitted 29 December, 2021; v1 submitted 12 October, 2021;
originally announced October 2021.
-
Spectrally peaked proton beams shock accelerated from an optically shaped overdense gas jet by a near-infrared laser
Authors:
George S. Hicks,
Oliver C. Ettlinger,
Marco Borghesi,
David C. Carroll,
Robert J. Clarke,
Emma-Jane Ditter,
Timothy P. Frazer,
Ross J. Gray,
Aodhan McIlvenny,
Paul McKenna,
Charlotte A. J. Palmer,
Louise Willingale,
Zulfikar Najmudin
Abstract:
We report on the generation of impurity-free proton beams from an overdense gas jet driven by a near-infrared laser ($λ_L=1.053$ $\mathrmμ m$). The gas profile was shaped prior to the interaction using a controlled prepulse. Without this optical shaping, a 30$\pm$4 nCsr$^{-1}$ thermal spectrum was detected transversely to the laser propagation direction with a high energy 8.27$\pm$7 MeV, narrow en…
▽ More
We report on the generation of impurity-free proton beams from an overdense gas jet driven by a near-infrared laser ($λ_L=1.053$ $\mathrmμ m$). The gas profile was shaped prior to the interaction using a controlled prepulse. Without this optical shaping, a 30$\pm$4 nCsr$^{-1}$ thermal spectrum was detected transversely to the laser propagation direction with a high energy 8.27$\pm$7 MeV, narrow energy spread (6$\pm$2 %) bunch containing 45$\pm$7 pCsr$^{-1}$. In contrast, with optical shaping the radial component was not detected and instead forward going protons were detected with energy 1.32$\pm$2 MeV, 12.9$\pm$3 % energy spread, and charge 400$\pm$30 pCsr$^{-1}$. Both the forward going and radial narrow energy spread features are indicative of collisionless shock acceleration of the protons.
△ Less
Submitted 28 April, 2021;
originally announced April 2021.
-
Axion Dark Matter eXperiment: Detailed Design and Operations
Authors:
R. Khatiwada,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
D. V. Mitchell,
T. Braine,
C. Bartram,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Will,
G. Carosi,
N. Woollett,
S. Durham,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath
, et al. (26 additional authors not shown)
Abstract:
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technolog…
▽ More
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as state-of-the-art quantum limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable Microstrip Superconducting Quantum Interference Device (SQUID) Amplifier (MSA), in Run 1A, and a Josephson Parametric Amplifier (JPA), in Run 1B, along with novel analysis tools that characterize the system noise temperature.
△ Less
Submitted 30 September, 2020;
originally announced October 2020.
-
Extended Search for the Invisible Axion with the Axion Dark Matter Experiment
Authors:
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
M. S. Taubman,
J. Clarke,
A. Dove,
A. Eddins
, et al. (17 additional authors not shown)
Abstract:
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode c…
▽ More
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode crossings using an alternate cavity configuration. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first stage signal amplifier.
△ Less
Submitted 1 November, 2019; v1 submitted 18 October, 2019;
originally announced October 2019.
-
Piezoelectrically Tuned Multimode Cavity Search for Axion Dark Matter
Authors:
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
R. Cervantes,
N. Du,
N. Force,
S. Kimes,
R. Ottens,
L. J. Rosenberg,
G. Rybka,
J. Yang,
G. Carosi,
N. Woollett,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
R. Bradley,
E. J. Daw,
A. Agrawal,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley
, et al. (9 additional authors not shown)
Abstract:
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, highe…
▽ More
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM$_{010}$ and TM$_{020}$ modes.
△ Less
Submitted 3 January, 2019;
originally announced January 2019.
-
A Search for Invisible Axion Dark Matter with the Axion Dark Matter Experiment
Authors:
N. Du,
N. Force,
R. Khatiwada,
E. Lentz,
R. Ottens,
L. J Rosenberg,
G. Rybka,
G. Carosi,
N. Woolett,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
C. Boutan,
N. S. Oblath,
R. Bradley,
E. J. Daw,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley,
N. Crisosto,
J. R. Gleason,
S. Jois,
P. Sikivie,
I. Stern
, et al. (3 additional authors not shown)
Abstract:
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from t…
▽ More
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultra-low-noise SQUID amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses.
△ Less
Submitted 17 April, 2018; v1 submitted 16 April, 2018;
originally announced April 2018.
-
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Authors:
Marco Battaglieri,
Alberto Belloni,
Aaron Chou,
Priscilla Cushman,
Bertrand Echenard,
Rouven Essig,
Juan Estrada,
Jonathan L. Feng,
Brenna Flaugher,
Patrick J. Fox,
Peter Graham,
Carter Hall,
Roni Harnik,
JoAnne Hewett,
Joseph Incandela,
Eder Izaguirre,
Daniel McKinsey,
Matthew Pyle,
Natalie Roe,
Gray Rybka,
Pierre Sikivie,
Tim M. P. Tait,
Natalia Toro,
Richard Van De Water,
Neal Weiner
, et al. (226 additional authors not shown)
Abstract:
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
△ Less
Submitted 14 July, 2017;
originally announced July 2017.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Constraining portals with displaced Higgs decay searches at the LHC
Authors:
Jackson D. Clarke
Abstract:
It is very easy to write down models in which long-lived particles decaying to standard model states are pair-produced via Higgs decays, resulting in the signature of approximately back-to-back pairs of displaced narrow hadronic jets and/or lepton jets at the LHC. The LHC collaborations have already searched for such signatures with no observed excess. This paper describes a Monte Carlo method to…
▽ More
It is very easy to write down models in which long-lived particles decaying to standard model states are pair-produced via Higgs decays, resulting in the signature of approximately back-to-back pairs of displaced narrow hadronic jets and/or lepton jets at the LHC. The LHC collaborations have already searched for such signatures with no observed excess. This paper describes a Monte Carlo method to reinterpret the searches. The method relies on (ideally multidimensional) efficiency tables, thus we implore collaborations to include them in any future work. Exclusion regions in mixing-mass parameter space are presented which constrain portal models.
△ Less
Submitted 23 September, 2015; v1 submitted 30 April, 2015;
originally announced May 2015.
-
Design and performance of the ADMX SQUID-based microwave receiver
Authors:
S. J. Asztalos,
G. Carosi,
C. Hagmann,
D. Kinion,
K. van Bibber,
M. Hotz,
L. J Rosenberg,
G. Rybka,
A. Wagner,
J. Hoskins,
C. Martin,
N. S. Sullivan,
D. B. Tanner,
R. Bradley,
John Clarke
Abstract:
The Axion Dark Matter eXperiment (ADMX) was designed to detect ultra-weakly interacting relic axion particles by searching for their conversion to microwave photons in a resonant cavity positioned in a strong magnetic field. Given the extremely low expected axion-photon conversion power we have designed, built and operated a microwave receiver based on a Superconducting QUantum Interference Device…
▽ More
The Axion Dark Matter eXperiment (ADMX) was designed to detect ultra-weakly interacting relic axion particles by searching for their conversion to microwave photons in a resonant cavity positioned in a strong magnetic field. Given the extremely low expected axion-photon conversion power we have designed, built and operated a microwave receiver based on a Superconducting QUantum Interference Device (SQUID). We describe the ADMX receiver in detail as well as the analysis of narrow band microwave signals. We demonstrate the sustained use of a SQUID amplifier operating between 812 and 860 MHz with a noise temperature of 1 K. The receiver has a noise equivalent power of 1.1x10^-24 W/sqrt(Hz) in the band of operation for an integration time of 1.8x10^3 s.
△ Less
Submitted 20 May, 2011;
originally announced May 2011.
-
A Search for Hidden Sector Photons with ADMX
Authors:
A. Wagner,
G. Rybka,
M. Hotz,
L. J Rosenberg,
S. J. Asztalos,
G. Carosi,
C. Hagmann,
D. Kinion,
K. van Bibber,
J. Hoskins,
C. Martin,
P. Sikivie,
D. B. Tanner,
R. Bradley,
J. Clarke
Abstract:
Hidden U(1) gauge symmetries are common to many extensions of the Standard Model proposed to explain dark matter. The hidden gauge vector bosons of such extensions may mix kinetically with Standard Model photons, providing a means for electromagnetic power to pass through conducting barriers. The ADMX detector was used to search for hidden vector bosons originating in an emitter cavity driven with…
▽ More
Hidden U(1) gauge symmetries are common to many extensions of the Standard Model proposed to explain dark matter. The hidden gauge vector bosons of such extensions may mix kinetically with Standard Model photons, providing a means for electromagnetic power to pass through conducting barriers. The ADMX detector was used to search for hidden vector bosons originating in an emitter cavity driven with microwave power. We exclude hidden vector bosons with kinetic couplings χ > 3.48x10-8 for masses less than 3 μeV. This limit represents an improvement of more than two orders of magnitude in sensitivity relative to previous cavity experiments.
△ Less
Submitted 28 October, 2010; v1 submitted 21 July, 2010;
originally announced July 2010.