-
An accurate solar axions ray-tracing response of BabyIAXO
Authors:
S. Ahyoune,
K. Altenmueller,
I. Antolin,
S. Basso,
P. Brun,
F. R. Candon,
J. F. Castel,
S. Cebrian,
D. Chouhan,
R. Della Ceca,
M. Cervera-Cortes,
V. Chernov,
M. M. Civitani,
C. Cogollos,
E. Costa,
V. Cotroneo,
T. Dafni,
A. Derbin,
K. Desch,
M. C. Diaz-Martin,
A. Diaz-Morcillo,
D. Diez-Ibanez,
C. Diez Pardos,
M. Dinter,
B. Doebrich
, et al. (102 additional authors not shown)
Abstract:
BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet that is pointing to the sun. The resulting X-rays are focused by appropriate X-ray optics and detected by sensitive low-background detectors placed at th…
▽ More
BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet that is pointing to the sun. The resulting X-rays are focused by appropriate X-ray optics and detected by sensitive low-background detectors placed at the focal spot. The aim of this article is to provide an accurate quantitative description of the different components (such as the magnet, optics, and X-ray detectors) involved in the detection of axions. Our efforts have focused on developing robust and integrated software tools to model these helioscope components, enabling future assessments of modifications or upgrades to any part of the IAXO axion helioscope and evaluating the potential impact on the experiment's sensitivity. In this manuscript, we demonstrate the application of these tools by presenting a precise signal calculation and response analysis of BabyIAXO's sensitivity to the axion-photon coupling. Though focusing on the Primakoff solar flux component, our virtual helioscope model can be used to test different production mechanisms, allowing for direct comparisons within a unified framework.
△ Less
Submitted 29 November, 2024; v1 submitted 21 November, 2024;
originally announced November 2024.
-
Contribution of gaseous tritium source rear wall to tritium beta-spectrum in Troitsk nu-mass experiment
Authors:
V. G. Chernov,
V. S. Pantuev
Abstract:
We avaluate the contribution of electron scattering on the rear wall of a windowless gaseous tritium source in the Troitsk nu-mass setup. There is a finite probability for them to scatter, return back and reach the detector. A such additional component distorts the measured electron spectrum. We calculate the scattering on the rear side of the vacuum pipe by the GEANT4 simulation and trace the ele…
▽ More
We avaluate the contribution of electron scattering on the rear wall of a windowless gaseous tritium source in the Troitsk nu-mass setup. There is a finite probability for them to scatter, return back and reach the detector. A such additional component distorts the measured electron spectrum. We calculate the scattering on the rear side of the vacuum pipe by the GEANT4 simulation and trace the electrons back through the magnetic fields to the spectrometer and registration system. The contribution is a few orders of magnitude smaller compared to the original spectrum at the end of the beta-spectrum of 18.6 keV but reaches 2\% at 11 keV. Taking into account this rear wall scattering we can fit well the measured spectrum in search for a sterile neutrino component in the tritium beta decay.
△ Less
Submitted 26 September, 2024;
originally announced September 2024.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
First measeurements in search for keV-sterile neutrino in tritium beta-decay by Troitsk nu-mass experiment
Authors:
J. N. Abdurashitov,
A. I. Belesev,
V. G. Chernov,
E. V. Geraskin,
A. A. Golubev,
P. V. Grigorieva,
G. A. Koroteev,
N. A. Likhovid,
A. A. Nozik,
V. S. Pantuev,
V. I. Parfenov,
A. K. Skasyrskaya,
I. I. Tkachev,
S. V. Zadorozhny
Abstract:
We present the first measurements of tritium beta-decay spectrum in the electron energy range 16-18.6 keV. The goal is to find distortions which may correspond to the presence of a heavy sterile neutrinos. A possible contribution of this kind would manifest itself as a kink in the spectrum with a similar shape but with end point shifted by the value of a heavy neutrino mass. We set a new upper lim…
▽ More
We present the first measurements of tritium beta-decay spectrum in the electron energy range 16-18.6 keV. The goal is to find distortions which may correspond to the presence of a heavy sterile neutrinos. A possible contribution of this kind would manifest itself as a kink in the spectrum with a similar shape but with end point shifted by the value of a heavy neutrino mass. We set a new upper limits to the neutrino mixing matrix element U^2_{e4} which improve existing limits by a factor from 2 to 5 in the mass range 0.1-2 keV.
△ Less
Submitted 21 June, 2017; v1 submitted 31 March, 2017;
originally announced March 2017.
-
Electron scattering on hydrogen and deuterium molecules at 14-25 keV by the "Troitsk nu-mass" experiment
Authors:
D. N. Abdurashitov,
A. I. Belesev,
V. G. Chernov,
E. V. Geraskin,
A. A. Golubev,
G. A. Koroteev,
N. A. Likhovid,
A. A. Nozik,
V. S. Pantuev,
V. I. Parfenov,
A. K. Skasyrskaya,
S. V. Zadorozhny
Abstract:
We've performed precise measurements of electron scattering on molecular hydrogen and deuterium by using the "Troitsk nu-mass" setup. Electrons were generated by the electron gun with an energy line width better than 0.3 eV. The electron energies were 14, 17, 18.7, 19 and 25 keV. The windowless gaseous tritium source (WGTS) was filled by hydrogen isotopes and served as a target. The total column d…
▽ More
We've performed precise measurements of electron scattering on molecular hydrogen and deuterium by using the "Troitsk nu-mass" setup. Electrons were generated by the electron gun with an energy line width better than 0.3 eV. The electron energies were 14, 17, 18.7, 19 and 25 keV. The windowless gaseous tritium source (WGTS) was filled by hydrogen isotopes and served as a target. The total column density was adjusted to form a length of 0.35--0.7 of the electron mean free path. The integral spectrum of scattered electrons was measured by the electrostatic spectrometer with a magnetic adiabatic collimation and relative energy resolution 8.3 10^{-5}. As a result, the shapes of molecular excitation and ionization spectra were extracted for both isotopes. We did not find any difference between hydrogen and deuterium targets. The relative energy dependence was extracted too.
△ Less
Submitted 14 March, 2016;
originally announced March 2016.
-
The current status of "Troitsk nu-mass" experiment in search for sterile neutrino
Authors:
D. N. Abdurashitov,
A. I. Belesev,
A. I. Berlev,
V. G. Chernov,
E. V. Geraskin,
A. A. Golubev,
G. A. Koroteev,
N. A. Likhovid,
A. A. Lokhov,
A. I. Markin,
A. A. Nozik,
V. S. Pantuev,
V. I. Parfenov,
A. K. Skasyrskaya,
N. A. Titov,
I. I. Tkachev,
F. V. Tkachov,
S. V. Zadorozhny
Abstract:
We propose a new experiment to search for a sterile neutrino in a few keV mass range at the "Troitsk nu-mass" facility. The expected signature corresponds to a kink in the electron energy spectrum in tritium beta-decay. The new goal compared to our previous experiment will be precision spectrum measurements well below end point. The experimental installation consists of a windowless gaseous tritiu…
▽ More
We propose a new experiment to search for a sterile neutrino in a few keV mass range at the "Troitsk nu-mass" facility. The expected signature corresponds to a kink in the electron energy spectrum in tritium beta-decay. The new goal compared to our previous experiment will be precision spectrum measurements well below end point. The experimental installation consists of a windowless gaseous tritium source and a high resolution electromagnetic spectrometer. We estimate that the current bounds on the sterile neutrino mixing parameter can be improved by an order of magnitude in the mass range under 5 keV without major upgrade of the existing equipment. Upgrades of calibration, data acquisition and high voltage systems will allow to improve the bounds by another order of magnitude.
△ Less
Submitted 11 November, 2015; v1 submitted 2 April, 2015;
originally announced April 2015.
-
Measurements of integral muon intensity at large zenith angles
Authors:
A. N. Dmitrieva,
D. V. Chernov,
R. P. Kokoulin,
K. G. Kompaniets,
G. Mannocchi,
A. A. Petrukhin,
O. Saavedra,
V. V. Shutenko,
D. A. Timashkov,
G. Trinchero,
I. I. Yashin
Abstract:
High-statistics data on near-horizontal muons collected with Russian-Italian coordinate detector DECOR are analyzed. Precise measurements of muon angular distributions in zenith angle interval from 60 to 90 degrees have been performed. In total, more than 20 million muons are selected. Dependences of the absolute integral muon intensity on zenith angle for several threshold energies ranging from…
▽ More
High-statistics data on near-horizontal muons collected with Russian-Italian coordinate detector DECOR are analyzed. Precise measurements of muon angular distributions in zenith angle interval from 60 to 90 degrees have been performed. In total, more than 20 million muons are selected. Dependences of the absolute integral muon intensity on zenith angle for several threshold energies ranging from 1.7 GeV to 7.2 GeV are derived. Results for this region of zenith angles and threshold energies have been obtained for the first time. The dependence of integral intensity on zenith angle and threshold energy is well fitted by a simple analytical formula.
△ Less
Submitted 28 November, 2006;
originally announced November 2006.