Skip to main content

Showing 1–33 of 33 results for author: Chapman, J

Searching in archive hep-ex. Search in all archives.
.
  1. arXiv:2505.10440  [pdf, ps, other

    hep-ex nucl-ex

    First Results on the Search for Lepton Number Violating Neutrinoless Double Beta Decay with the LEGEND-200 Experiment

    Authors: H. Acharya, N. Ackermann, M. Agostini, A. Alexander, C. Andreoiu, G. R. Araujo, F. T. Avignone III, M. Babicz, W. Bae, A. Bakalyarov, M. Balata, A. S. Barabash, P. S. Barbeau, C. J. Barton, L. Baudis, C. Bauer, E. Bernieri, L. Bezrukov, K. H. Bhimani, V. Biancacci, E. Blalock, S. J. Borden, G. Borghi, F. Borra, B. Bos , et al. (234 additional authors not shown)

    Abstract: The LEGEND collaboration is searching for neutrinoless double beta ($0νββ$) decay by operating high-purity germanium detectors enriched in $^{76}$Ge in a low-background liquid argon environment. Building on key technological innovations from GERDA and the MAJORANA DEMONSTRATOR, LEGEND-200 has performed a first $0νββ$ decay search based on 61 kg yr of data. Over half of this exposure comes from our… ▽ More

    Submitted 16 June, 2025; v1 submitted 15 May, 2025; originally announced May 2025.

    Comments: Prepared for submission to Physical Review Letters

  2. arXiv:2503.20732  [pdf, other

    nucl-ex hep-ex hep-ph physics.ins-det

    Nuclear recoil detection with color centers in bulk lithium fluoride

    Authors: Gabriela A. Araujo, Laura Baudis, Nathaniel Bowden, Jordan Chapman, Anna Erickson, Mariano Guerrero Perez, Adam A. Hecht, Samuel C. Hedges, Patrick Huber, Vsevolod Ivanov, Igor Jovanovic, Giti A. Khodaparast, Brenden A. Magill, Jose Maria Mateos, Maverick Morrison, Nicholas W. G. Smith, Patrick Stengel, Stuti Surani, Nikita Vladimirov, Keegan Walkup, Christian Wittweg, Xianyi Zhang

    Abstract: We present initial results on nuclear recoil detection based on the fluorescence of color centers created by nuclear recoils in lithium fluoride. We use gamma rays, fast and thermal neutrons, and study the difference in responses they induce, showing that this type of detector is rather insensitive to gamma rays. We use light-sheet fluorescence microscopy to image nuclear recoil tracks from fast a… ▽ More

    Submitted 26 March, 2025; originally announced March 2025.

    Comments: 23 pages, 15 figures

  3. arXiv:2303.12571  [pdf, other

    hep-ex physics.ins-det

    The New Small Wheel electronics

    Authors: G. Iakovidis, L. Levinson, Y. Afik, C. Alexa, T. Alexopoulos, J. Ameel, D. Amidei, D. Antrim, A. Badea, C. Bakalis, H. Boterenbrood, R. S. Brener, S. Chan, J. Chapman, G. Chatzianastasiou, H. Chen, M. C. Chu, R. M. Coliban, T. Costa de Paiva, G. de Geronimo, R. Edgar, N. Felt, S. Francescato, M. Franklin, T. Geralis , et al. (77 additional authors not shown)

    Abstract: The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector te… ▽ More

    Submitted 25 May, 2023; v1 submitted 22 March, 2023; originally announced March 2023.

    Comments: 61 pages

    Journal ref: JINST 18 P05012 (2023)

  4. arXiv:1810.10396  [pdf, other

    physics.ins-det hep-ex

    Operation and performance of microhexcavity pixel detector in gas discharge and avalanche mode

    Authors: A. Mulski, Y. Benhammou, J. W. Chapman, A. Das, E. Etzion, C. Ferretti, P. S. Friedman, R. P. Johnson, D. S. Levin, N. Kamp, H. Ochoa, M. Raviv-Moshe, N. Ristow

    Abstract: The Microhexcavity Panel ( muHex) is a novel gaseous micropattern particle detector comprised of a dense array of close-packed hexagonal pixels, each operating as an independent detection unit for ionizing radiation. It is a second generation detector derived from plasma panel detectors and microcavity detectors. The muHex is under development to be deployed as a scalable, fast timing (ns) and her… ▽ More

    Submitted 24 October, 2018; originally announced October 2018.

    Comments: Accepted Nuclear Inst. and Methods in Physics Research, A (2018)

  5. arXiv:1803.04165  [pdf, other

    physics.comp-ph hep-ex

    HEP Software Foundation Community White Paper Working Group - Detector Simulation

    Authors: HEP Software Foundation, :, J Apostolakis, M Asai, S Banerjee, R Bianchi, P Canal, R Cenci, J Chapman, G Corti, G Cosmo, S Easo, L de Oliveira, A Dotti, V Elvira, S Farrell, L Fields, K Genser, A Gheata, M Gheata, J Harvey, F Hariri, R Hatcher, K Herner, M Hildreth , et al. (40 additional authors not shown)

    Abstract: A working group on detector simulation was formed as part of the high-energy physics (HEP) Software Foundation's initiative to prepare a Community White Paper that describes the main software challenges and opportunities to be faced in the HEP field over the next decade. The working group met over a period of several months in order to review the current status of the Full and Fast simulation appl… ▽ More

    Submitted 12 March, 2018; originally announced March 2018.

    Report number: HSF-CWP-2017-07

  6. arXiv:1712.06982  [pdf, other

    physics.comp-ph hep-ex

    A Roadmap for HEP Software and Computing R&D for the 2020s

    Authors: Johannes Albrecht, Antonio Augusto Alves Jr, Guilherme Amadio, Giuseppe Andronico, Nguyen Anh-Ky, Laurent Aphecetche, John Apostolakis, Makoto Asai, Luca Atzori, Marian Babik, Giuseppe Bagliesi, Marilena Bandieramonte, Sunanda Banerjee, Martin Barisits, Lothar A. T. Bauerdick, Stefano Belforte, Douglas Benjamin, Catrin Bernius, Wahid Bhimji, Riccardo Maria Bianchi, Ian Bird, Catherine Biscarat, Jakob Blomer, Kenneth Bloom, Tommaso Boccali , et al. (285 additional authors not shown)

    Abstract: Particle physics has an ambitious and broad experimental programme for the coming decades. This programme requires large investments in detector hardware, either to build new facilities and experiments, or to upgrade existing ones. Similarly, it requires commensurate investment in the R&D of software to acquire, manage, process, and analyse the shear amounts of data to be recorded. In planning for… ▽ More

    Submitted 19 December, 2018; v1 submitted 18 December, 2017; originally announced December 2017.

    Report number: HSF-CWP-2017-01

    Journal ref: Comput Softw Big Sci (2019) 3, 7

  7. arXiv:1709.04391  [pdf

    physics.ins-det hep-ex

    Microhexcavity Plasma Panel Detectors

    Authors: Alexis Mulski, Daniel S. Levin, Yan Benhamou, John W. Chapman, Achintya Das, Erez Etzion, Claudio Ferretti, Peter S. Friedman, Meny Raviv-Moshe, David Reikher, Nicholas Ristow

    Abstract: Plasma panel detectors are a variant of micropattern detectors that are sensitive to ionizing radiation. They are motivated by the design and operation of plasma display panels. The detectors consist of arrays of electrically and optically isolated pixels defined by metallized cavities embedded in a dielectric substrate. These are hermetically sealed gaseous detectors that use exclusively non-hydr… ▽ More

    Submitted 18 September, 2017; v1 submitted 13 September, 2017; originally announced September 2017.

    Comments: Talk presented at the APS Division of Particles and Fields Meeting (DPF 2017), July 31-August 4, 2017, Fermilab. C170731

  8. arXiv:1608.05381  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics

    Authors: LUX Collaboration, D. S. Akerib, S. Alsum, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, A. Bradley, R. Bramante, P. Brás, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison , et al. (82 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. T… ▽ More

    Submitted 26 October, 2016; v1 submitted 18 August, 2016; originally announced August 2016.

    Comments: 24 pages, 15 figures, 6 tables

  9. arXiv:1608.05309  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Proposed low-energy absolute calibration of nuclear recoils in a dual-phase noble element TPC using D-D neutron scattering kinematics

    Authors: J. R. Verbus, C. A. Rhyne, D. C. Malling, M. Genecov, S. Ghosh, A. G. Moskowitz, S. Chan, J. J. Chapman, L. de Viveiros, C. H. Faham, S. Fiorucci, D. Q. Huang, M. Pangilinan, W. C. Taylor, R. J. Gaitskell

    Abstract: We propose a new technique for the calibration of nuclear recoils in large noble element dual-phase time projection chambers used to search for WIMP dark matter in the local galactic halo. This technique provides an $\textit{in situ}$ measurement of the low-energy nuclear recoil response of the target media using the measured scattering angle between multiple neutron interactions within the detect… ▽ More

    Submitted 18 August, 2016; originally announced August 2016.

    Comments: 21 pages, 18 figures, 6 tables

    Journal ref: Nucl. Instrum. Methods A851, 68 (2017)

  10. Results on the Spin-Dependent Scattering of Weakly Interacting Massive Particles on Nucleons from the Run 3 Data of the LUX Experiment

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, A. Bradley, R. Bramante, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, L. de Viveiros, A. Dobi, J. E. Y. Dobson , et al. (77 additional authors not shown)

    Abstract: We present the first experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of… ▽ More

    Submitted 16 May, 2016; v1 submitted 10 February, 2016; originally announced February 2016.

    Comments: 6 pages, 2 figures

    Journal ref: Phys. Rev. Lett. 116, 161302 (2016)

  11. arXiv:1512.03506  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, A. Bradley, R. Bramante, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, L. de Viveiros, A. Dobi, J. E. Y. Dobson , et al. (77 additional authors not shown)

    Abstract: We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background… ▽ More

    Submitted 16 May, 2016; v1 submitted 10 December, 2015; originally announced December 2015.

    Comments: Accepted by Phys. Rev. Lett

    Journal ref: Phys. Rev. Lett. 116, 161301 (2016)

  12. arXiv:1512.03133  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Tritium calibration of the LUX dark matter experiment

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araújo, X. Bai, A. J. Bailey, J. Balajthy, P. Beltrame, E. P. Bernard, A. Bernstein, T. P. Biesiadzinski, E. M. Boulton, A. Bradley, R. Bramante, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, A. Currie, J. E. Cutter, T. J. R. Davison, L. de Viveiros, A. Dobi, J. E. Y. Dobson , et al. (76 additional authors not shown)

    Abstract: We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the resu… ▽ More

    Submitted 5 May, 2016; v1 submitted 9 December, 2015; originally announced December 2015.

    Journal ref: Phys. Rev. D 93, 072009 (2016)

  13. arXiv:1509.06637  [pdf

    physics.ins-det hep-ex

    FPGA Implementation of a Fixed Latency Scheme in a Signal Packet Router for the Upgrade of ATLAS Forward Muon Trigger Electronics

    Authors: Jinhong Wang, Xueye Hu, Thomas Schwarz, Junjie Zhu, J. W. Chapman, Tiesheng Dai, Bing Zhou

    Abstract: We propose a new fixed latency scheme for Xilinx gigabit transceivers that will be used in the upgrade of the ATLAS forward muon spectrometer at the Large Hadron Collider. The fixed latency scheme is implemented in a 4.8 Gbps link between a frontend data serializer ASIC and a packet router. To achieve fixed latency, we use IO delay and dedicated carry in resources in a Xilinx FPGA, while minimally… ▽ More

    Submitted 20 September, 2015; originally announced September 2015.

    Comments: 8 pages, 8 figures, accepted by IEEE - Transactions on Nuclear Science

  14. arXiv:1509.06636  [pdf

    physics.ins-det hep-ex

    Characterization of a Serializer ASIC chip for the upgrade of the ATLAS muon detector

    Authors: Jinhong Wang, Liang Guan, Ziru Sang, J. W. Chapman, Tiesheng Dai, Bing Zhou, Junjie Zhu

    Abstract: We report on the design of a serializer ASIC to be used in the ATLAS forward muon detector for trigger data transmission. We discuss the performance of a prototype chip covering power dissipation, latency and stable operating line rate. Tests show that the serializer is capable of running at least at 5.76 Gbps with a bit error ratio below 1x10^{-15}, and a power consumption of 200 mW running at 4.… ▽ More

    Submitted 20 September, 2015; originally announced September 2015.

    Comments: 7 pages, 8 figures, accepted by IEEE-Transactions on Nuclear Science

  15. arXiv:1403.3454  [pdf, other

    physics.ins-det hep-ex

    Development of a plasma panel radiation detector

    Authors: R. Ball, J. R. Beene, M. Ben-Moshe, Y. Benhammou, R. Bensimon, J. W. Chapman, E. Etzion, C. Ferretti, P. S. Friedman, D. S. Levin, Y. Silver, R. L. Varner, C. Weaverdyck, R. Wetzel, B. Zhou, T. Anderson, K. McKinny, E. H. Bentefour

    Abstract: This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were t… ▽ More

    Submitted 14 June, 2014; v1 submitted 13 March, 2014; originally announced March 2014.

    Comments: Submitted to NIM

    Journal ref: Nuclear Inst. and Methods in Physics Research, A (2014), pp. 122-132

  16. arXiv:1402.3731  [pdf, other

    hep-ex astro-ph.CO astro-ph.IM physics.ins-det

    A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment

    Authors: M. Szydagis, D. S. Akerib, H. M. Araujo, X. Bai, A. J. Bailey, J. Balajthy, E. Bernard, A. Bernstein, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, T. Coffey, A. Currie, L. de Viveiros, A. Dobi, J. Dobson, E. Druszkiewicz, B. Edwards, C. H. Faham, S. Fiorucci , et al. (55 additional authors not shown)

    Abstract: LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keV… ▽ More

    Submitted 25 February, 2014; v1 submitted 15 February, 2014; originally announced February 2014.

    Comments: 16 pages, 3 figures, to appear in the proceedings of The 10th International Symposium on Cosmology and Particle Astrophysics (CosPA2013); fixed author list and added info on new calibration

  17. arXiv:1401.6116  [pdf, ps, other

    hep-ex hep-ph physics.ins-det

    Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier

    Authors: M. Demarteau, R. Lipton, H. Nicholson, I. Shipsey, D. Akerib, A. Albayrak-Yetkin, J. Alexander, J. Anderson, M. Artuso, D. Asner, R. Ball, M. Battaglia, C. Bebek, J. Beene, Y. Benhammou, E. Bentefour, M. Bergevin, A. Bernstein, B. Bilki, E. Blucher, G. Bolla, D. Bortoletto, N. Bowden, G. Brooijmans, K. Byrum , et al. (189 additional authors not shown)

    Abstract: These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss… ▽ More

    Submitted 23 January, 2014; originally announced January 2014.

    Comments: 50 pages

  18. arXiv:1310.8214  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    First results from the LUX dark matter experiment at the Sanford Underground Research Facility

    Authors: LUX Collaboration, D. S. Akerib, H. M. Araujo, X. Bai, A. J. Bailey, J. Balajthy, S. Bedikian, E. Bernard, A. Bernstein, A. Bolozdynya, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, C. Chan, J. J. Chapman, A. A. Chiller, C. Chiller, K. Clark, T. Coffey, A. Currie, A. Curioni, S. Dazeley, L. de Viveiros, A. Dobi , et al. (78 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li… ▽ More

    Submitted 5 February, 2014; v1 submitted 30 October, 2013; originally announced October 2013.

    Comments: Accepted by Phys. Rev. Lett. Appendix A included as supplementary material with PRL article

    Journal ref: Phys. Rev. Lett. 112, 091303 (2014)

  19. arXiv:1305.2277  [pdf

    physics.ins-det hep-ex

    Plasma panel-based radiation detectors

    Authors: Peter Friedman, Robert Ball, James Beene, Yan Benhammou, Meny Ben-Moshe, Hassan Bentefour, J. W. Chapman, Erez Etzion, Claudio Ferretti, Daniel Levin, Yiftah Silver, Robert Varner, Curtis Weaverdyck, Bing Zhou

    Abstract: The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates… ▽ More

    Submitted 10 May, 2013; originally announced May 2013.

    Journal ref: J. Soc. Info. Display 21, No. 1, 46-54 (2013)

  20. arXiv:1211.5399  [pdf

    physics.ins-det hep-ex

    Plasma Panel Sensors for Particle and Beam Detection

    Authors: Peter S. Friedman, Robert Ball, James R. Beene, Yan Benhammou, E. H. Bentefour, J. W. Chapman, Erez Etzion, Claudio Ferretti, Nir Guttman, Daniel S. Levin, Meny Ben-Moshe, Yiftah Silver, Robert L. Varner, Curtis Weaverdyck, Bing Zhou

    Abstract: The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials… ▽ More

    Submitted 22 November, 2012; originally announced November 2012.

    Comments: 2012 IEEE NSS

  21. arXiv:1211.3788  [pdf, other

    physics.ins-det hep-ex

    The Large Underground Xenon (LUX) Experiment

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bolozdynya, A. Bradley, D. Byram, S. B. Cahn, C. Camp, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, A. Chiller, C. Chiller, K. Clark, T. Classen, T. Coffey, A. Curioni, E. Dahl, S. Dazeley, L. de Viveiros, A. Dobi, E. Dragowsky, E. Druszkiewicz , et al. (69 additional authors not shown)

    Abstract: The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100… ▽ More

    Submitted 21 November, 2012; v1 submitted 15 November, 2012; originally announced November 2012.

    Comments: 50 pages, 16 figures

    Journal ref: Nuclear Inst. and Methods in Physics Research A704 (2013) 111 - 126

  22. arXiv:1210.6696  [pdf, other

    physics.ins-det hep-ex

    Studies on fast triggering and high precision tracking with Resistive Plate Chambers

    Authors: G. Aielli, B. Bilki, R. Ball, J. W. Chapman, R. Cardarelli, T. Dai, E. Diehl, J. Dubbert, C. Ferretti, H. Feng, K. Francis, L. Guan, L. Han, S. Hou, D. Levin, B. Li, L. Liu, L. Paolozzi, J. Repond, J. Roloff, R. Santonico, H. Y. Song, X. L. Wang, Y. Wu, L. Xia , et al. (5 additional authors not shown)

    Abstract: We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering… ▽ More

    Submitted 24 October, 2012; originally announced October 2012.

    Comments: 7 pages, 11 figures, submitted to Nucl. Instru. Meth

  23. arXiv:1210.4569  [pdf, other

    astro-ph.IM hep-ex hep-ph physics.ins-det

    Technical Results from the Surface Run of the LUX Dark Matter Experiment

    Authors: LUX Collaboration, D. S. Akerib, X. Bai, E. Bernard, A. Bernstein, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, J. J. Chapman, T. Coffey, A. Dobi, E. Dragowsky, E. Druszkiewicz, B. Edwards, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, M. Gilchriese, C. Hall, M. Hanhardt, M. Ihm, R. G. Jacobsen, L. Kastens , et al. (42 additional authors not shown)

    Abstract: We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed i… ▽ More

    Submitted 22 February, 2013; v1 submitted 16 October, 2012; originally announced October 2012.

  24. Measurements of atmospheric neutrinos and antineutrinos in the MINOS Far Detector

    Authors: MINOS Collaboration, P. Adamson, C. Backhouse, G. Barr, M. Bishai, A. S. T. Blake, G. J. Bock, D. J. Boehnlein, D. Bogert, S. V. Cao, J. D. Chapman, S. Childress, J. A. B. Coelho, L. Corwin, D. Cronin-Hennessy, I. Z. Danko, J. K. de Jong, N. E. Devenish, M. V. Diwan, C. O. Escobar, J. J. Evans, E. Falk, G. J. Feldman, M. V. Frohne, H. R. Gallagher , et al. (88 additional authors not shown)

    Abstract: This paper reports measurements of atmospheric neutrino and antineutrino interactions in the MINOS Far Detector, based on 2553 live-days (37.9 kton-years) of data. A total of 2072 candidate events are observed. These are separated into 905 contained-vertex muons and 466 neutrino-induced rock-muons, both produced by charged-current $ν_μ$ and $\barν_μ$ interactions, and 701 contained-vertex showers,… ▽ More

    Submitted 15 August, 2012; v1 submitted 14 August, 2012; originally announced August 2012.

    Comments: 22 pages, 19 figures, submitted to Phys. Rev. D

    Report number: FERMILAB-PUB-12-468-E

  25. A Bayesian technique for improving the sensitivity of the atmospheric neutrino L/E analysis

    Authors: Andrew Blake, John Chapman, Mark Thomson

    Abstract: This paper outlines a method for improving the precision of atmospheric neutrino oscillation measurements. One experimental signature for these oscillations is an observed deficit in the rate of $ν_μ$ charged-current interactions with an oscillatory dependence on $L_ν/E_ν$, where $L_ν$ is the neutrino propagation distance, and $E_ν$ is the neutrino energy. For contained-vertex atmospheric neutrino… ▽ More

    Submitted 17 August, 2012; v1 submitted 14 August, 2012; originally announced August 2012.

    Comments: 12 pages, 7 figures, submitted to Nucl. Instrum. Methods A, accompanies arXiv:1208.2915 [hep-ex]

    Report number: FERMILAB-PUB-12-469-E; CU-HEP-2012-13

  26. arXiv:1205.2272  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    An Ultra-Low Background PMT for Liquid Xenon Detectors

    Authors: D. S. Akerib, X. Bai, E. Bernard, A. Bernstein, A. Bradley, D. Byram, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, Y-D. Chan, K. Clark, T. Coffey, L. deViveiros, M. Dragowsky, E. Druszkiewicz, B. Edwards, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook, M. Ihm , et al. (42 additional authors not shown)

    Abstract: Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other det… ▽ More

    Submitted 24 June, 2013; v1 submitted 10 May, 2012; originally announced May 2012.

    Comments: v2 updated to include content after reviewer comments (Sep 2012)

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 703, 1 March 2013, Pages 1-6

  27. arXiv:1112.1376  [pdf, ps, other

    physics.ins-det hep-ex

    Radio-assay of Titanium samples for the LUX Experiment

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, Y-D. Chan, K. Clark, T. Classen, T. Coffey, S. Dazeley, L. deViveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook , et al. (41 additional authors not shown)

    Abstract: We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample w… ▽ More

    Submitted 12 February, 2012; v1 submitted 6 December, 2011; originally announced December 2011.

    Comments: The LUX Collaboration

  28. arXiv:1111.2074  [pdf, other

    physics.data-an hep-ex nucl-ex

    LUXSim: A Component-Centric Approach to Low-Background Simulations

    Authors: D. S. Akerib, X. Bai, S. Bedikian, E. Bernard, A. Bernstein, A. Bradley, S. B. Cahn, M. C. Carmona-Benitez, D. Carr, J. J. Chapman, K. Clark, T. Classen, T. Coffey, S. Dazeley, L. de Viveiros, M. Dragowsky, E. Druszkiewicz, C. H. Faham, S. Fiorucci, R. J. Gaitskell, K. R. Gibson, C. Hall, M. Hanhardt, B. Holbrook, M. Ihm , et al. (38 additional authors not shown)

    Abstract: Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpo… ▽ More

    Submitted 8 November, 2011; originally announced November 2011.

    Comments: 45 pages, 15 figures

  29. arXiv:1007.0487  [pdf

    physics.ins-det hep-ex

    Large-Area Plasma-Panel Radiation Detectors for Nuclear Medicine Imaging to Homeland Security and the Super Large Hadron Collider

    Authors: Peter S. Friedman, Robert Ball, J. Wehrley Chapman, Daniel S. Levin, Curtis Weaverdyck, Bing Zhou, Yan Benhammou, Erez Etzion, M. Ben Moshe, Yiftah Silver, James R. Beene, Robert L. Varner Jr.

    Abstract: A new radiation sensor derived from plasma panel display technology is introduced. It has the capability to detect ionizing and non-ionizing radiation over a wide energy range and the potential for use in many applications. The principle of operation is described and some early results presented.

    Submitted 3 July, 2010; originally announced July 2010.

    Comments: International Display Symposium, Seattle, WA, May 2010

  30. arXiv:1007.0486  [pdf

    physics.ins-det hep-ex

    Plasma Panel Detectors for MIP Detection for the SLHC and a Test Chamber Design

    Authors: Robert Ball, John W. Chapman, Erez Etzion, Peter S. Friedman, Daniel S. Levin, Meny Ben Moshe, Curtis Weaverdyck, Bing Zhou

    Abstract: Performance demands for high and super-high luminosity at the LHC (up to 10^35 cm^(-2) sec^(-1) after the 2017 shutdown) and at future colliders demand high resolution tracking detectors with very fast time response and excellent temporal and spatial resolution. We are investigating a new radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma tele… ▽ More

    Submitted 3 July, 2010; originally announced July 2010.

    Comments: IEEE Nuclear Science Symposium Conference (Orlando), (2009)

    Journal ref: IEEE Nucl.Sci.Symp.Conf.Rec. 2009:1321-1327,2009

  31. arXiv:0901.0512  [pdf

    hep-ex

    Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics

    Authors: The ATLAS Collaboration, G. Aad, E. Abat, B. Abbott, J. Abdallah, A. A. Abdelalim, A. Abdesselam, O. Abdinov, B. Abi, M. Abolins, H. Abramowicz, B. S. Acharya, D. L. Adams, T. N. Addy, C. Adorisio, P. Adragna, T. Adye, J. A. Aguilar-Saavedra, M. Aharrouche, S. P. Ahlen, F. Ahles, A. Ahmad, H. Ahmed, G. Aielli, T. Akdogan , et al. (2587 additional authors not shown)

    Abstract: A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on… ▽ More

    Submitted 14 August, 2009; v1 submitted 28 December, 2008; originally announced January 2009.

  32. Search for First-Generation Scalar Leptoquarks in $\bm{p \bar{p}}$ collisions at $\sqrt{s}$=1.96 TeV

    Authors: The CDF Collaboration, D. Acosta, J. Adelman, T. Affolder, T. Akimoto, M. G. Albrow, D. Ambrose, S. Amerio, D. Amidei, A. Anastassov, K. Anikeev, A. Annovi, J. Antos, M. Aoki, G. Apollinari, T. Arisawa, J-F. Arguin, A. Artikov, W. Ashmanskas, A. Attal, F. Azfar, P. Azzi-Bacchetta, N. Bacchetta, H. Bachacou, W. Badgett , et al. (605 additional authors not shown)

    Abstract: We report on a search for pair production of first-generation scalar leptoquarks ($LQ$) in $p \bar{p}$ collisions at $\sqrt{s}$=1.96 TeV using an integrated luminosity of 203 $pb^{-1}$ collected at the Fermilab Tevatron collider by the CDF experiment. We observe no evidence for $LQ$ production in the topologies arising from $LQ \bar{LQ} \to eqeq$ and $LQ \bar{LQ} \to eq νq$, and derive 95% C.L.… ▽ More

    Submitted 29 June, 2005; originally announced June 2005.

    Comments: submitted to PRL

    Report number: FERMILAB-PUB-05-254-E

    Journal ref: Phys.Rev.D72:051107,2005

  33. Comparison of Three-jet Events in Proton-Antiproton Collisions at Center-of-mass Energy 1.8 TeV to Predictions from a Next-to-leading Order QCD Calculation

    Authors: D. Acosta, T. Affolder, M. G. Albrow, D. Ambrose, D. Amidei, K. Anikeev, J. Antos, G. Apollinari, T. Arisawa, A. Artikov, W. Ashmanskas, F. Azfar, P. Azzi-Bacchetta, N. Bacchetta, H. Bachacou, W. Badgett, A. Barbaro-Galtieri, V. E. Barnes, B. A. Barnett, S. Baroiant, M. Barone, G. Bauer, F. Bedeschi, S. Behari, S. Belforte , et al. (388 additional authors not shown)

    Abstract: The properties of three-jet events with total transverse energy greater than 320 GeV and individual jet energy greater than 20 GeV have been analyzed and compared to absolute predictions from a next-to-leading order (NLO) perturbative QCD calculation. These data, of integrated luminosity 86 pb^-1, were recorded by the CDF Experiment for proton-antiproton collisions at sqrt{s}=1.8 TeV. This study… ▽ More

    Submitted 6 October, 2004; originally announced October 2004.

    Journal ref: Phys.Rev.D71:032002,2005