-
Production, Quality Assurance and Quality Control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber
Authors:
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick,
M. Bloem,
S. Blua,
V. Bocci
, et al. (280 additional authors not shown)
Abstract:
The DarkSide-20k dark matter direct detection experiment will employ a 21 m^2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output f…
▽ More
The DarkSide-20k dark matter direct detection experiment will employ a 21 m^2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. 16 Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the quality assurance and quality control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision flip-chip bonding, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.
△ Less
Submitted 9 July, 2025;
originally announced July 2025.
-
Fermionic sub-GeV Dark Matter from evaporating Primordial Black Holes at DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
R. Calabrese,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
P. Cavalcante
, et al. (105 additional authors not shown)
Abstract:
We present a search for boosted dark matter from Primordial Black Holes (PBH) evaporation using the DarkSide-50 ionization-signal-only dataset corresponding to the experiment's ($12202\pm180$) ${\rm kg\: d}$ exposure. We focus on evaporation of PBHs with masses in the range [$10^{14},\,10^{16}$] g producing Dirac fermionic dark matter particles with sub-GeV kinetic energy. These relativistic parti…
▽ More
We present a search for boosted dark matter from Primordial Black Holes (PBH) evaporation using the DarkSide-50 ionization-signal-only dataset corresponding to the experiment's ($12202\pm180$) ${\rm kg\: d}$ exposure. We focus on evaporation of PBHs with masses in the range [$10^{14},\,10^{16}$] g producing Dirac fermionic dark matter particles with sub-GeV kinetic energy. These relativistic particles, with energies up to hundreds of MeV, can generate detectable signals for masses below $\mathcal{O}(100)$ MeV. The absence of a signal enables setting complementary limits to those derived from cosmological observations and direct detection searches for cosmic ray-boosted dark matter.
△ Less
Submitted 19 May, 2025;
originally announced May 2025.
-
Flow and thermal modelling of the argon volume in the DarkSide-20k TPC
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick,
M. Bloem
, et al. (279 additional authors not shown)
Abstract:
The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ~50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we…
▽ More
The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ~50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (~40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of $^{83\text{m}}$Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.
△ Less
Submitted 26 June, 2025; v1 submitted 11 March, 2025;
originally announced March 2025.
-
Impact of extreme ultraviolet radiation on the scintillation of pure and xenon-doped liquid argon
Authors:
P. Agnes,
Q. Berger,
M. Bomben,
M. Campestrini,
M. Caravati,
A. F. V. Cortez,
D. Franco,
C. Galbiati,
G. K. Giovanetti,
T. Hessel,
C. Hidalgo,
S. Hoceini,
C. Houriez,
P. Kunzé,
A. Jamil,
J. Machts,
E. Nikoloudaki,
D. Pailot,
E. Pantic,
C. Savarese,
P. Stringari,
A. Sung,
L. Scotto Lavina,
J-M Simon,
H. Vieira de Souza
, et al. (3 additional authors not shown)
Abstract:
The Xenon-Argon Technology (X-ArT) collaboration presents a study on the dynamics of pure and xenon-doped liquid argon (LAr) scintillation. Using two types of silicon photomultipliers sensitive to different wavelength ranges, we provide evidence in favor of a contribution from long-lived (>10 $μ$s) extreme ultraviolet (EUV) lines emitted from argon atomic states, which enhances the light yield. Th…
▽ More
The Xenon-Argon Technology (X-ArT) collaboration presents a study on the dynamics of pure and xenon-doped liquid argon (LAr) scintillation. Using two types of silicon photomultipliers sensitive to different wavelength ranges, we provide evidence in favor of a contribution from long-lived (>10 $μ$s) extreme ultraviolet (EUV) lines emitted from argon atomic states, which enhances the light yield. This component is present in both pure and xenon-doped LAr, becoming more pronounced at higher xenon concentrations, where it complements the traditional collisional energy transfer process. To explain this mechanism, we develop a comprehensive model of the Xe-doped LAr scintillation process that integrates both collisional and radiative contributions. Additionally, we investigate how xenon doping affects LAr scintillation light yield and pulse shape discrimination. Finally, we hypothesize that the EUV component may explain the emission of spurious electrons, a known challenge in light dark matter searches using noble liquids.
By characterizing the scintillation dynamics in Xe-doped LAr, identifying the long-lived EUV component, and exploring the potential origin of spurious electrons, this work lays the groundwork for optimizing detector performance and advancing the design and sensitivity of future noble liquid particle detectors.
△ Less
Submitted 25 April, 2025; v1 submitted 30 October, 2024;
originally announced October 2024.
-
Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (294 additional authors not shown)
Abstract:
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout t…
▽ More
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout the experiment's lifetime of over 10 years. Continuous removal of impurities and radon from the UAr is essential for maximising signal yield and mitigating background. We are developing an efficient and powerful cryogenics system with a gas purification loop with a target circulation rate of 1000 slpm. Central to its design is a condenser operated with liquid nitrogen which is paired with a gas heat exchanger cascade, delivering a combined cooling power of more than 8 kW. Here we present the design choices in view of the DS-20k requirements, in particular the condenser's working principle and the cooling control, and we show test results obtained with a dedicated benchmarking platform at CERN and LNGS. We find that the thermal efficiency of the recirculation loop, defined in terms of nitrogen consumption per argon flow rate, is 95 % and the pressure in the test cryostat can be maintained within $\pm$(0.1-0.2) mbar. We further detail a 5-day cool-down procedure of the test cryostat, maintaining a cooling rate typically within -2 K/h, as required for the DS-20k inner detector. Additionally, we assess the circuit's flow resistance, and the heat transfer capabilities of two heat exchanger geometries for argon phase change, used to provide gas for recirculation. We conclude by discussing how our findings influence the finalisation of the system design, including necessary modifications to meet requirements and ongoing testing activities.
△ Less
Submitted 19 February, 2025; v1 submitted 26 August, 2024;
originally announced August 2024.
-
DarkSide-20k sensitivity to light dark matter particles
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (289 additional authors not shown)
Abstract:
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more arg…
▽ More
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV/c$^2$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP--nucleon interaction cross-sections below $1\times10^{-42}$ cm$^2$ is achievable for WIMP masses above 800 MeV/c$^2$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV/c$^2$.
△ Less
Submitted 6 January, 2025; v1 submitted 8 July, 2024;
originally announced July 2024.
-
A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (290 additional authors not shown)
Abstract:
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surround…
▽ More
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
Long-term temporal stability of the DarkSide-50 dark matter detector
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time project…
▽ More
The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.
△ Less
Submitted 22 May, 2024; v1 submitted 30 November, 2023;
originally announced November 2023.
-
Search for dark matter annual modulation with DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range abo…
▽ More
Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above $40~{\rm eV_{ee}}$, the lowest threshold ever achieved in such a search.
△ Less
Submitted 22 November, 2024; v1 submitted 14 July, 2023;
originally announced July 2023.
-
Search for low mass dark matter in DarkSide-50: the bayesian network approach
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (119 additional authors not shown)
Abstract:
We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there…
▽ More
We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.
△ Less
Submitted 26 April, 2023; v1 submitted 3 February, 2023;
originally announced February 2023.
-
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
Authors:
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. Ch. Avetisov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
E. Berzin,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino
, et al. (274 additional authors not shown)
Abstract:
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These stu…
▽ More
Dark matter lighter than 10 GeV/c$^2$ encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino floor for GeV-scale masses and significant sensitivity down to 10 MeV/c$^2$ considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector's sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.
△ Less
Submitted 20 June, 2023; v1 submitted 2 September, 2022;
originally announced September 2022.
-
Search for dark matter particle interactions with electron final states with DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
V. Cataudella
, et al. (120 additional authors not shown)
Abstract:
We present a search for dark matter particles with sub-GeV/$c^2$ masses whose interactions have final state electrons using the DarkSide-50 experiment's (12306 $\pm$ 184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section $\barσ_e$, the axioelectric coupling constant $g_{Ae}$, and the dark pho…
▽ More
We present a search for dark matter particles with sub-GeV/$c^2$ masses whose interactions have final state electrons using the DarkSide-50 experiment's (12306 $\pm$ 184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section $\barσ_e$, the axioelectric coupling constant $g_{Ae}$, and the dark photon kinetic mixing parameter $κ$. We also set the first dark matter direct-detection constraints on the mixing angle $\left|U_{e4}\right|^2$ for keV sterile neutrinos.
△ Less
Submitted 16 February, 2023; v1 submitted 25 July, 2022;
originally announced July 2022.
-
Search for dark matter-nucleon interactions via Migdal effect with DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c$^2$ mass dark matter. We present new constraints for sub-GeV/c$^2$ dark matter using…
▽ More
Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c$^2$ mass dark matter. We present new constraints for sub-GeV/c$^2$ dark matter using the dual-phase liquid argon time projection chamber of the DarkSide-50 experiment with an exposure of (12306 $\pm$ 184) kg d. The analysis is based on the ionization signal alone and significantly enhances the sensitivity of DarkSide-50, enabling sensitivity to dark matter with masses down to 40 MeV/c$^2$. Furthermore, it sets the most stringent upper limit on the spin independent dark matter nucleon cross section for masses below $3.6$ GeV/c$^2$.
△ Less
Submitted 16 February, 2023; v1 submitted 25 July, 2022;
originally announced July 2022.
-
Search for low-mass dark matter WIMPs with 12 ton-day exposure of DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
V. Cataudella,
P. Cavalcante
, et al. (119 additional authors not shown)
Abstract:
We report on the search for dark matter WIMPs in the mass range below 10 GeV/c$^2$, from the analysis of the entire dataset acquired with a low-radioactivity argon target by the DarkSide-50 experiment at LNGS. The new analysis benefits from more accurate calibration of the detector response, improved background model, and better determination of systematic uncertainties, allowing us to accurately…
▽ More
We report on the search for dark matter WIMPs in the mass range below 10 GeV/c$^2$, from the analysis of the entire dataset acquired with a low-radioactivity argon target by the DarkSide-50 experiment at LNGS. The new analysis benefits from more accurate calibration of the detector response, improved background model, and better determination of systematic uncertainties, allowing us to accurately model the background rate and spectra down to 0.06 keV$_{er}$. A 90% C.L. exclusion limit for the spin-independent cross section of 3 GeV/c$^2$ mass WIMP on nucleons is set at 6$\times$10$^{-43}$ cm$^2$, about a factor 10 better than the previous DarkSide-50 limit. This analysis extends the exclusion region for spin-independent dark matter interactions below the current experimental constraints in the $[1.2, 3.6]$ GeV/c$^2$ WIMP mass range.
△ Less
Submitted 24 February, 2023; v1 submitted 25 July, 2022;
originally announced July 2022.
-
Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50
Authors:
The DarkSide collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella,
P. Cavalcante
, et al. (114 additional authors not shown)
Abstract:
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c$^2$ mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionizat…
▽ More
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c$^2$ mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to $\sim$180~eV$_{er}$, exploiting $^{37}$Ar and $^{39}$Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Moreover, we present a model-dependent determination of the ionization response to nuclear recoils down to $\sim$500~eV$_{nr}$, the lowest ever achieved in liquid argon, using \textit{in situ} neutron calibration sources and external datasets from neutron beam experiments.
△ Less
Submitted 15 September, 2021; v1 submitted 16 July, 2021;
originally announced July 2021.
-
A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella
, et al. (114 additional authors not shown)
Abstract:
Finding unequivocal evidence of dark matter interactions in a particle detector is a major objective of physics research. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nucleus down to the so-called neutrino floor, in a mass range from few GeV's to hundredths of TeV's. Based on the successful operation of the DarkSide-5…
▽ More
Finding unequivocal evidence of dark matter interactions in a particle detector is a major objective of physics research. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nucleus down to the so-called neutrino floor, in a mass range from few GeV's to hundredths of TeV's. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all kind of observed events, is essential for an optimal design of the new experiment. In this paper, we report on a particular set of events, which were not used for dark matter searches. Namely, standard two-pulse scintillation-ionization signals accompanied by a small amplitude third pulse, originating from single or few electrons, in a time window of less than a maximum drift time. We compare our findings to those of a recent paper of the LUX Collaboration (D.S.Akerib et al. Phys.Rev.D 102, 092004). Indeed, both experiments observe events related to photoionization of the cathode. From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths around 128 nm, in liquid argon. Also, both experiments observe events likely related to photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be one order of magnitude smaller in DarkSide-50 than in LUX. This result, together with the much larger measured electron lifetime, coherently hints toward a lower concentration of contaminants in DarkSide-50 than in LUX.
△ Less
Submitted 27 November, 2021; v1 submitted 16 July, 2021;
originally announced July 2021.
-
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
Authors:
The DarkSide collaboration,
C. E. Aalseth,
S. Abdelhakim,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
V. Barbaryan,
A. Barrado Olmedo,
G. Batignani
, et al. (290 additional authors not shown)
Abstract:
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the…
▽ More
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.
△ Less
Submitted 26 February, 2021; v1 submitted 4 April, 2020;
originally announced April 2020.
-
Effective field theory interactions for liquid argon target in DarkSide-50 experiment
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli
, et al. (143 additional authors not shown)
Abstract:
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper…
▽ More
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between $2.4 \times 10^{-45} \, \mathrm{cm}^2$ and $2.3 \times 10^{-42} \, \mathrm{cm}^2$ (8.9 $\times 10^{-45} \, \mathrm{cm}^2$ and 6.0 $\times 10^{-42} \, \mathrm{cm}^2$) for WIMPs of mass of 100 $\mathrm{GeV/c^2}$ (1000 $\mathrm{GeV/c^2}$) at 90\% confidence level.
△ Less
Submitted 18 February, 2020;
originally announced February 2020.
-
The Electronics, Trigger and Data Acquisition System for the Liquid Argon Time Projection Chamber of the DarkSide-50 Search for Dark Matter
Authors:
DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela
, et al. (155 additional authors not shown)
Abstract:
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which proce…
▽ More
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.
△ Less
Submitted 20 November, 2017; v1 submitted 31 July, 2017;
originally announced July 2017.
-
Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
H. O. Back,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
S. Catalanotti,
V. Cataudella
, et al. (125 additional authors not shown)
Abstract:
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination techni…
▽ More
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination technique, and the measurement of the residual 39Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.
△ Less
Submitted 26 September, 2017; v1 submitted 18 July, 2017;
originally announced July 2017.