-
Direct neutrino-mass measurement based on 259 days of KATRIN data
Authors:
M. Aker,
D. Batzler,
A. Beglarian,
J. Behrens,
J. Beisenkötter,
M. Biassoni,
B. Bieringer,
Y. Biondi,
F. Block,
S. Bobien,
M. Böttcher,
B. Bornschein,
L. Bornschein,
T. S. Caldwell,
M. Carminati,
A. Chatrabhuti,
S. Chilingaryan,
B. A. Daniel,
K. Debowski,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards
, et al. (124 additional authors not shown)
Abstract:
The fact that neutrinos carry a non-vanishing rest mass is evidence of physics beyond the Standard Model of elementary particles. Their absolute mass bears important relevance from particle physics to cosmology. In this work, we report on the search for the effective electron antineutrino mass with the KATRIN experiment. KATRIN performs precision spectroscopy of the tritium $β$-decay close to the…
▽ More
The fact that neutrinos carry a non-vanishing rest mass is evidence of physics beyond the Standard Model of elementary particles. Their absolute mass bears important relevance from particle physics to cosmology. In this work, we report on the search for the effective electron antineutrino mass with the KATRIN experiment. KATRIN performs precision spectroscopy of the tritium $β$-decay close to the kinematic endpoint. Based on the first five neutrino-mass measurement campaigns, we derive a best-fit value of $m_ν^{2} = {-0.14^{+0.13}_{-0.15}}~\mathrm{eV^2}$, resulting in an upper limit of $m_ν< {0.45}~\mathrm{eV}$ at 90 % confidence level. With six times the statistics of previous data sets, amounting to 36 million electrons collected in 259 measurement days, a substantial reduction of the background level and improved systematic uncertainties, this result tightens KATRIN's previous bound by a factor of almost two.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Constraints on the decay of $^{180m}$Ta
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (34 additional authors not shown)
Abstract:
$^{180m}$Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known $β…
▽ More
$^{180m}$Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known $β$ and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the MAJORANA DEMONSTRATOR, an experimental search for the neutrinoless double-beta decay of $^{76}$Ge using an array of high-purity germanium detectors, to search for the decay of $^{180m}$Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the $^{180m}$Ta half-life on the different decay channels. With new limits up to 1.5 x $10^{19}$ years, we improved existing limits by one to two orders of magnitude. This result is the most sensitive search for a single $β$ and electron capture decay ever achieved.
△ Less
Submitted 2 June, 2023;
originally announced June 2023.
-
Final Result of the MAJORANA DEMONSTRATOR's Search for Neutrinoless Double-$β$ Decay in $^{76}$Ge
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (35 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR searched for neutrinoless double-$β$ decay ($0νββ$) of $^{76}$Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-background shield. The arrays operated with up to 40.4 kg of detectors (27.2 kg enriched to $\sim$88\% in $^{76}$Ge). From these measurements, the DEMONSTRATOR has accumulated 64.5 kg yr of enriched active exposure. With a…
▽ More
The MAJORANA DEMONSTRATOR searched for neutrinoless double-$β$ decay ($0νββ$) of $^{76}$Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-background shield. The arrays operated with up to 40.4 kg of detectors (27.2 kg enriched to $\sim$88\% in $^{76}$Ge). From these measurements, the DEMONSTRATOR has accumulated 64.5 kg yr of enriched active exposure. With a world-leading energy resolution of 2.52 keV FWHM at the 2039 keV $Q_{ββ}$ (0.12\%), we set a half-life limit of $0νββ$ in $^{76}$Ge at $T_{1/2}>8.3\times10^{25}$ yr (90\% C.L.). This provides a range of upper limits on $m_{ββ}$ of $(113-269)$ meV (90\% C.L.), depending on the choice of nuclear matrix elements.
△ Less
Submitted 10 February, 2023; v1 submitted 15 July, 2022;
originally announced July 2022.
-
Search for Lorentz-Invariance Violation with the first KATRIN data
Authors:
M. Aker,
D. Batzler,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards
, et al. (108 additional authors not shown)
Abstract:
Some extensions of the Standard Model of Particle Physics allow for Lorentz invariance and Charge-Parity-Time (CPT)-invariance violations. In the neutrino sector strong constraints have been set by neutrino-oscillation and time-of-flight experiments. However, some Lorentz-invariance-violating parameters are not accessible via these probes. In this work, we focus on the parameters…
▽ More
Some extensions of the Standard Model of Particle Physics allow for Lorentz invariance and Charge-Parity-Time (CPT)-invariance violations. In the neutrino sector strong constraints have been set by neutrino-oscillation and time-of-flight experiments. However, some Lorentz-invariance-violating parameters are not accessible via these probes. In this work, we focus on the parameters $(a_{\text{of}}^{(3)})_{00}$, $(a_{\text{of}}^{(3)})_{10}$ and $(a_{\text{of}}^{(3)})_{11}$ which would manifest themselves in a non-isotropic beta-decaying source as a sidereal oscillation and an overall shift of the spectral endpoint. Based on the data of the first scientific run of the KATRIN experiment, we set the first limit on $\left|(a_{\text{of}}^{(3)})_{11}\right|$ of $< 3.7\cdot10^{-6}$ GeV at 90\% confidence level. Moreover, we derive new constraints on $(a_{\text{of}}^{(3)})_{00}$ and $(a_{\text{of}}^{(3)})_{10}$.
△ Less
Submitted 13 July, 2022;
originally announced July 2022.
-
Exotic dark matter search with the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (34 additional authors not shown)
Abstract:
With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos, $ν_s \rightarrow ν_a$. We report n…
▽ More
With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos, $ν_s \rightarrow ν_a$. We report new limits on fermionic dark matter absorption ($χ+ A \rightarrow ν+ A$) and sub-GeV DM-nucleus 3$\rightarrow$2 scattering ($χ+ χ+ A \rightarrow φ+ A$), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the (1--100)-keV low energy region of a 37.5-kg y exposure collected by the Demonstrator between May 2016 and November 2019, using a set of $^{76}$Ge-enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation.
△ Less
Submitted 26 July, 2024; v1 submitted 21 June, 2022;
originally announced June 2022.
-
Search for solar axions via axion-photon coupling with the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (33 additional authors not shown)
Abstract:
Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in solid state detection experiments with enhancements due to coherent Primakoff-Bragg scattering. The Majorana Demonstrator experiment has searched for solar axions with a set of $^{76}$Ge-enriched high purity germanium dete…
▽ More
Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in solid state detection experiments with enhancements due to coherent Primakoff-Bragg scattering. The Majorana Demonstrator experiment has searched for solar axions with a set of $^{76}$Ge-enriched high purity germanium detectors using a 33 kg-yr exposure collected between Jan. 2017 and Nov. 2019. A temporal-energy analysis gives a new limit on the axion-photon coupling as $g_{aγ}<1.45\times 10^{-9}$ GeV$^{-1}$ (95% C.I.) for axions with mass up to 100 eV/$c^2$. This improves laboratory-based limits between about 1 eV/$c^2$ and 100 eV/$c^2$.
△ Less
Submitted 22 August, 2022; v1 submitted 12 June, 2022;
originally announced June 2022.
-
Experimental study of 13C(α,n)16O reactions in the Majorana Demonstrator calibration data
Authors:
MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimate…
▽ More
Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129-keV $γ$-rays emitted from the excited $^{16}$O states that are populated when the incoming $α$-particles exceed the reaction Q-value. Thanks to the excellent energy performance of the \textsc{Demonstrator}'s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by \textsc{Geant4} simulations, a comparison between the observed 6129-keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent, albeit with large statistical uncertainties. This agreement provides support for background projections from ($α,n$)-reactions in future double-beta decay search efforts.
△ Less
Submitted 11 July, 2022; v1 submitted 27 March, 2022;
originally announced March 2022.
-
KATRIN: Status and Prospects for the Neutrino Mass and Beyond
Authors:
M. Aker,
M. Balzer,
D. Batzler,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
M. Biassoni,
B. Bieringer,
F. Block,
S. Bobien,
L. Bombelli,
D. Bormann,
B. Bornschein,
L. Bornschein,
M. Böttcher,
C. Brofferio,
C. Bruch,
T. Brunst,
T. S. Caldwell,
M. Carminati,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
O. Cremonesi
, et al. (137 additional authors not shown)
Abstract:
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a su…
▽ More
The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN's design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.
△ Less
Submitted 16 June, 2023; v1 submitted 15 March, 2022;
originally announced March 2022.
-
Search for charge nonconservation and Pauli exclusion principle violation with the Majorana Demonstrator
Authors:
MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detec…
▽ More
Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detectors of the \MJD\ experiment. Using a 37.5 kg-yr exposure, we report a lower limit on the electron mean lifetime, improving the previous best limit for the $e \rightarrow ν_e \overline{ν_e} ν_e$ decay channel by more than an order of magnitude. We also present searches for two types of violation of the Pauli exclusion principle, setting limits on the probability of an electron to be found in a symmetric quantum state.
△ Less
Submitted 25 February, 2025; v1 submitted 3 March, 2022;
originally announced March 2022.
-
New Constraint on the Local Relic Neutrino Background Overdensity with the First KATRIN Data Runs
Authors:
M. Aker,
D. Batzler,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel
, et al. (107 additional authors not shown)
Abstract:
We report on the direct cosmic relic neutrino background search from the first two science runs of the KATRIN experiment in 2019. Beta-decay electrons from a high-purity molecular tritium gas source are analyzed by a high-resolution MAC-E filter around the kinematic endpoint at 18.57 keV. The analysis is sensitive to a local relic neutrino overdensity of 9.7e10 (1.1e11) at a 90% (95%) confidence l…
▽ More
We report on the direct cosmic relic neutrino background search from the first two science runs of the KATRIN experiment in 2019. Beta-decay electrons from a high-purity molecular tritium gas source are analyzed by a high-resolution MAC-E filter around the kinematic endpoint at 18.57 keV. The analysis is sensitive to a local relic neutrino overdensity of 9.7e10 (1.1e11) at a 90% (95%) confidence level. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint accounting for relic neutrino captures in the Tritium source reveals no significant overdensity. This work improves the results obtained by the previous kinematic neutrino mass experiments at Los Alamos and Troitsk. We furthermore update the projected final sensitivity of the KATRIN experiment to <1e10 at 90% confidence level, by relying on updated operational conditions.
△ Less
Submitted 9 February, 2022;
originally announced February 2022.
-
Search for Spontaneous Radiation from Wavefunction Collapse in the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe,
R. Henning
, et al. (29 additional authors not shown)
Abstract:
The Majorana Demonstrator neutrinoless double-beta decay experiment comprises a 44 kg (30 kg enriched in $^{76}\mathrm{Ge}$) array of $p$-type, point-contact germanium detectors. With its unprecedented energy resolution and ultralow backgrounds, Majorana also searches for rare event signatures from beyond standard model physics in the low energy region below 100 keV. In this Letter, we test the co…
▽ More
The Majorana Demonstrator neutrinoless double-beta decay experiment comprises a 44 kg (30 kg enriched in $^{76}\mathrm{Ge}$) array of $p$-type, point-contact germanium detectors. With its unprecedented energy resolution and ultralow backgrounds, Majorana also searches for rare event signatures from beyond standard model physics in the low energy region below 100 keV. In this Letter, we test the continuous spontaneous localization (CSL) model, one of the mathematically well-motivated wave function collapse models aimed at solving the long-standing unresolved quantum mechanical measurement problem. While the CSL predicts the existence of a detectable radiation signature in the x-ray domain, we find no evidence of such radiation in the 19--100 keV range in a 37.5 kg-y enriched germanium exposure collected between December 31, 2015, and November 27, 2019, with the Demonstrator. We explored both the non-mass-proportional (n-m-p) and the mass-proportional (m-p) versions of the CSL with two different assumptions: that only the quasifree electrons can emit the x-ray radiation and that the nucleus can coherently emit an amplified radiation. In all cases, we set the most stringent upper limit to date for the white CSL model on the collapse rate, $λ$, providing a factor of 40--100 improvement in sensitivity over comparable searches. Our limit is the most stringent for large parts of the allowed parameter space. If the result is interpreted in terms of the Diòsi-Penrose gravitational wave function collapse model, the lower bound with a 95% confidence level is almost an order of magnitude improvement over the previous best limit.
△ Less
Submitted 12 June, 2023; v1 submitted 2 February, 2022;
originally announced February 2022.
-
Improved eV-scale Sterile-Neutrino Constraints from the Second KATRIN Measurement Campaign
Authors:
M. Aker,
D. Batzler,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel
, et al. (106 additional authors not shown)
Abstract:
We present the results of the light sterile neutrino search from the second KATRIN measurement campaign in 2019. Approaching nominal activity, $3.76 \times 10^6$ tritium $β$-electrons are analyzed in an energy window extending down to $40\,$eV below the tritium endpoint at $E_0 = 18.57\,$keV. We consider the $3ν+1$ framework with three active and one sterile neutrino flavor. The analysis is sensit…
▽ More
We present the results of the light sterile neutrino search from the second KATRIN measurement campaign in 2019. Approaching nominal activity, $3.76 \times 10^6$ tritium $β$-electrons are analyzed in an energy window extending down to $40\,$eV below the tritium endpoint at $E_0 = 18.57\,$keV. We consider the $3ν+1$ framework with three active and one sterile neutrino flavor. The analysis is sensitive to a fourth mass eigenstate $m_4^2\lesssim1600\,$eV$^2$ and active-to-sterile mixing $|U_{e4}|^2 \gtrsim 6 \times 10^{-3}$. As no sterile-neutrino signal was observed, we provide improved exclusion contours on $m_4^2$ and $|U_{e4}|^2$ at $95\,$% C.L. Our results supersede the limits from the Mainz and Troitsk experiments. Furthermore, we are able to exclude the large $Δm_{41}^2$ solutions of the reactor antineutrino and gallium anomalies to a great extent. The latter has recently been reaffirmed by the BEST collaboration and could be explained by a sterile neutrino with large mixing. While the remaining solutions at small $Δm_{41}^2$ are mostly excluded by short-baseline reactor experiments, KATRIN is the only ongoing laboratory experiment to be sensitive to relevant solutions at large $Δm_{41}^2$ through a robust spectral shape analysis.
△ Less
Submitted 27 January, 2022;
originally announced January 2022.
-
The MAJORANA DEMONSTRATOR Readout Electronics System
Authors:
N. Abgrall,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
K. H. Bhimani,
B. Bos,
A. W. Bradley,
T. H. Burritt,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
R. J. Cooper,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko
, et al. (54 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper prov…
▽ More
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.
△ Less
Submitted 23 February, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.
-
First direct neutrino-mass measurement with sub-eV sensitivity
Authors:
M. Aker,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
L. La Cascio,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
K. Eitel,
E. Ellinger
, et al. (103 additional authors not shown)
Abstract:
We report the results of the second measurement campaign of the Karlsruhe Tritium Neutrino (KATRIN) experiment. KATRIN probes the effective electron anti-neutrino mass, $m_ν$, via a high-precision measurement of the tritium $β$-decay spectrum close to its endpoint at $18.6\,\mathrm{keV}$. In the second physics run presented here, the source activity was increased by a factor of 3.8 and the backgro…
▽ More
We report the results of the second measurement campaign of the Karlsruhe Tritium Neutrino (KATRIN) experiment. KATRIN probes the effective electron anti-neutrino mass, $m_ν$, via a high-precision measurement of the tritium $β$-decay spectrum close to its endpoint at $18.6\,\mathrm{keV}$. In the second physics run presented here, the source activity was increased by a factor of 3.8 and the background was reduced by $25\,\%$ with respect to the first campaign. A sensitivity on $m_ν$ of $0.7\,\mathrm{eV/c^2}$ at $90\,\%$ confidence level (CL) was reached. This is the first sub-eV sensitivity from a direct neutrino-mass experiment. The best fit to the spectral data yields $m_ν^2 = (0.26\pm0.34)\,\mathrm{eV^4/c^4}$, resulting in an upper limit of $m_ν<0.9\,\mathrm{eV/c^2}$ ($90\,\%$ CL). By combining this result with the first neutrino mass campaign, we find an upper limit of $m_ν<0.8\,\mathrm{eV/c^2}$ ($90\,\%$ CL).
△ Less
Submitted 18 May, 2021;
originally announced May 2021.
-
Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment
Authors:
M. Aker,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
R. M. D. Carney,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel,
E. Ellinger
, et al. (110 additional authors not shown)
Abstract:
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectromet…
▽ More
The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $β$-decay endpoint region with a sensitivity on $m_ν$ of 0.2$\,$eV/c$^2$ (90% CL). For this purpose, the $β$-electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6$\,$keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $β$-electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the \linebreak energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique.
We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% T$_2$ gas mixture at 30$\,$K, as used in the first KATRIN neutrino mass analyses, as well as a D$_2$ gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $σ(m_ν^2)<10^{-2}\,\mathrm{eV}^2$ [arXiv:2101.05253] in the KATRIN neutrino-mass measurement to a subdominant level.
△ Less
Submitted 14 May, 2021;
originally announced May 2021.
-
The Design, Construction, and Commissioning of the KATRIN Experiment
Authors:
M. Aker,
K. Altenmüller,
J. F. Amsbaugh,
M. Arenz,
M. Babutzka,
J. Bast,
S. Bauer,
H. Bechtler,
M. Beck,
A. Beglarian,
J. Behrens,
B. Bender,
R. Berendes,
A. Berlev,
U. Besserer,
C. Bettin,
B. Bieringer,
K. Blaum,
F. Block,
S. Bobien,
J. Bohn,
K. Bokeloh,
H. Bolz,
B. Bornschein,
L. Bornschein
, et al. (204 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.
△ Less
Submitted 11 June, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.
-
Analysis methods for the first KATRIN neutrino-mass measurement
Authors:
M. Aker,
K. Altenmüller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
K. Blaum,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
D. Díaz Barrero,
K. Debowski,
M. Deffert,
M. Descher,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (104 additional authors not shown)
Abstract:
We report on the data set, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the $β$-decay kinematics of molecular tritium. The source is highly pure, cryogenic T$_2$ gas. The $β$ electrons are guided along magnetic field lines toward a high-resolution, inte…
▽ More
We report on the data set, data handling, and detailed analysis techniques of the first neutrino-mass measurement by the Karlsruhe Tritium Neutrino (KATRIN) experiment, which probes the absolute neutrino-mass scale via the $β$-decay kinematics of molecular tritium. The source is highly pure, cryogenic T$_2$ gas. The $β$ electrons are guided along magnetic field lines toward a high-resolution, integrating spectrometer for energy analysis. A silicon detector counts $β$ electrons above the energy threshold of the spectrometer, so that a scan of the thresholds produces a precise measurement of the high-energy spectral tail. After detailed theoretical studies, simulations, and commissioning measurements, extending from the molecular final-state distribution to inelastic scattering in the source to subtleties of the electromagnetic fields, our independent, blind analyses allow us to set an upper limit of 1.1 eV on the neutrino-mass scale at a 90\% confidence level. This first result, based on a few weeks of running at a reduced source intensity and dominated by statistical uncertainty, improves on prior limits by nearly a factor of two. This result establishes an analysis framework for future KATRIN measurements, and provides important input to both particle theory and cosmology.
△ Less
Submitted 12 May, 2021; v1 submitted 13 January, 2021;
originally announced January 2021.
-
Bound on 3+1 active-sterile neutrino mixing from the first four-week science run of KATRIN
Authors:
M. Aker,
K. Altenmueller,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
B. Bieringer,
K. Blaum,
F. Block,
B. Bornschein,
L. Bornschein,
M. Boettcher,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
D. Diaz Barrero,
K. Debowski,
M. Deffert,
M. Descher,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (104 additional authors not shown)
Abstract:
We report on the light sterile neutrino search from the first four-week science run of the KATRIN experiment in~2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are analyzed by a high-resolution MAC-E filter down to 40 eV below the endpoint at 18.57 keV. We consider the framework with three active neutrinos and one sterile neutrino of mass $m_{4}$. The analysis is sen…
▽ More
We report on the light sterile neutrino search from the first four-week science run of the KATRIN experiment in~2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are analyzed by a high-resolution MAC-E filter down to 40 eV below the endpoint at 18.57 keV. We consider the framework with three active neutrinos and one sterile neutrino of mass $m_{4}$. The analysis is sensitive to a fourth mass state $m^2_{4} \lesssim$ 1000 eV$^2$ and to active-to-sterile neutrino mixing down to $|U_{e4}|^2 \gtrsim 2\cdot10^{-2}$. No significant spectral distortion is observed and exclusion bounds on the sterile mass and mixing are reported. These new limits supersede the Mainz results and improve the Troitsk bound for $m^2_{4} <$ 30 eV$^2$. The reactor and gallium anomalies are constrained for $ 100 < Δ{m}^2_{41} < 1000$ eV$^2$.
△ Less
Submitted 10 November, 2020;
originally announced November 2020.
-
$α$-event Characterization and Rejection in Point-Contact HPGe Detectors
Authors:
The MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
T. R. Edwards,
D. W. Edwins,
Yu. Efremenko,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (40 additional authors not shown)
Abstract:
P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical…
▽ More
P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the MAJORANA DEMONSTRATOR experiment, a search for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. $α$ decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $α$ identification, reliably identifying $α$ background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $α$ events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $0νββ$ region of interest window by an order of magnitude in the MAJORANA DEMONSTRATOR, and will be used in the upcoming LEGEND-200 experiment.
△ Less
Submitted 14 March, 2022; v1 submitted 23 June, 2020;
originally announced June 2020.
-
First operation of the KATRIN experiment with tritium
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
W. -J. Baek,
J. Barrett,
A. Beglarian,
J. Behrens,
A. Berlev,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
S. Chilingaryan,
W. Choi,
K. Debowski,
M. Deffert,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun
, et al. (146 additional authors not shown)
Abstract:
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.…
▽ More
The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay, provide a largely model-independent probe to the neutrino mass scale. The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to directly measure the effective electron antineutrino mass with a sensitivity of 0.2 eV 90% CL. In this work we report on the first operation of KATRIN with tritium which took place in 2018. During this commissioning phase of the tritium circulation system, excellent agreement of the theoretical prediction with the recorded spectra was found and stable conditions over a time period of 13 days could be established. These results are an essential prerequisite for the subsequent neutrino mass measurements with KATRIN in 2019.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
Authors:
M. Aker,
K. Altenmüller,
M. Arenz,
M. Babutzka,
J. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
K. Blaum,
F. Block,
S. Bobien,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
H. Bouquet,
T. Brunst,
T. S. Caldwell,
L. La Cascio,
S. Chilingaryan,
W. Choi,
T. J. Corona
, et al. (184 additional authors not shown)
Abstract:
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an…
▽ More
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of two and provides model-independent input to cosmological studies of structure formation.
△ Less
Submitted 13 September, 2019;
originally announced September 2019.
-
A Search for Neutrinoless Double-Beta Decay in $^{76}$Ge with 26 kg-yr of Exposure from the MAJORANA DEMONSTRATOR
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
V. Basu,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (39 additional authors not shown)
Abstract:
The MAJORANA Collaboration is operating an array of high purity Ge detectors to search for the neutrinoless double-beta decay of $^{76}$Ge. The MAJORANA DEMONSTRATOR consists of 44.1 kg of Ge detectors (29.7 kg enriched to 88% in $^{76}$Ge) split between two modules constructed from ultra-clean materials. Both modules are contained in a low-background shield at the Sanford Underground Research Fac…
▽ More
The MAJORANA Collaboration is operating an array of high purity Ge detectors to search for the neutrinoless double-beta decay of $^{76}$Ge. The MAJORANA DEMONSTRATOR consists of 44.1 kg of Ge detectors (29.7 kg enriched to 88% in $^{76}$Ge) split between two modules constructed from ultra-clean materials. Both modules are contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota. We present updated results on the search for neutrinoless double-beta decay in $^{76}$Ge with $26.0\pm0.5$ kg-yr of enriched exposure. With the DEMONSTRATOR's unprecedented energy resolution of 2.53 keV FWHM at $Q_{ββ}$, we observe one event in the region of interest with 0.65 events expected from the estimated background, resulting in a lower limit on the $^{76}$Ge neutrinoless double-beta decay half-life of $2.7\times10^{25}$ yr (90% CL) with a median sensitivity of $4.8\times10^{25}$ yr (90% CL). Depending on the matrix elements used, a 90% CL upper limit on the effective Majorana neutrino mass in the range of 200-433 meV is obtained. The measured background in the low-background configurations is $11.9\pm2.0$ counts/(FWHM t yr).
△ Less
Submitted 6 February, 2019;
originally announced February 2019.
-
Multi-site event discrimination for the MAJORANA DEMONSTRATOR
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe,
R. J. Hegedus,
L. Hehn
, et al. (38 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay in 76Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the neutrinoless double-beta decay region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysi…
▽ More
The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay in 76Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the neutrinoless double-beta decay region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysis cut applied to achieve this result, named AvsE, is described in this paper. This cut is developed to remove events whose waveforms are typical of multi-site energy deposits while retaining (90 +/- 3.5)% of single-site events. This pulse shape discrimination is based on the relationship between the maximum current and energy, and tuned using 228Th calibration source data. The efficiency uncertainty accounts for variation across detectors, energy, and time, as well as for the position distribution difference between calibration and $0νββ$ events, established using simulations.
△ Less
Submitted 16 January, 2019;
originally announced January 2019.
-
Search for Tri-Nucleon Decay in the Majorana Demonstrator
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (41 additional authors not shown)
Abstract:
The Majorana Demonstrator is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. We present the first limits for tri-nucleon decay-specific modes and invisible d…
▽ More
The Majorana Demonstrator is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. We present the first limits for tri-nucleon decay-specific modes and invisible decay modes for Ge isotopes. We find a half-life limit of $4.9 \times 10^{25}$ yr for the decay $^{76}{\rm Ge(ppn)} \to {}^{73}{\rm Zn}\ e^+π^+$ and $4.7\times10^{25}$ yr for the decay $^{76}{\rm Ge(ppp)} \to ^{73}{\rm Cu}\ e^+π^+π^+$. The half-life limit for the invisible tri-proton decay mode of $^{76}$Ge was found to be $7.5\times10^{24}$ yr.
△ Less
Submitted 26 March, 2019; v1 submitted 3 December, 2018;
originally announced December 2018.
-
First Limit on the Direct Detection of Lightly Ionizing Particles for Electric Charge as Low as $e$/1000 with the \textsc{Majorana Demonstrator}
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (39 additional authors not shown)
Abstract:
The \textsc{Majorana Demonstrator} is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly-ionizing particles with electrical charges…
▽ More
The \textsc{Majorana Demonstrator} is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly-ionizing particles with electrical charges less than $e$ are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the \textsc{Majorana Demonstrator} by searching for multiple- detector events with individual-detector energy depositions down to 1 keV. This search is background free and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as $e$/1000.
△ Less
Submitted 29 May, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
Authors:
LEGEND Collaboration,
N. Abgrall,
A. Abramov,
N. Abrosimov,
I. Abt,
M. Agostini,
M. Agartioglu,
A. Ajjaq,
S. I. Alvis,
F. T. Avignone III,
X. Bai,
M. Balata,
I. Barabanov,
A. S. Barabash,
P. J. Barton,
L. Baudis,
L. Bezrukov,
T. Bode,
A. Bolozdynya,
D. Borowicz,
A. Boston,
H. Boston,
S. T. P. Boyd,
R. Breier,
V. Brudanin
, et al. (208 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely…
▽ More
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.
△ Less
Submitted 6 September, 2017;
originally announced September 2017.
-
Initial Results from the MAJORANA DEMONSTRATOR
Authors:
S. R. Elliott,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (42 additional authors not shown)
Abstract:
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge)…
▽ More
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. The initial goals of the {\sc Demonstrator} are to establish the required background and scalability of a Ge-based, next-generation, tonne-scale experiment. Following a commissioning run that began in 2015, the first detector module started physics data production in early 2016. We will discuss initial results of the Module 1 commissioning and first physics run, as well as the status and potential physics reach of the full {\sc Majorana Demonstrator} experiment. The collaboration plans to complete the assembly of the second detector module by mid-2016 to begin full data production with the entire array.
△ Less
Submitted 4 October, 2016;
originally announced October 2016.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
Background Rejection in the DMTPC Dark Matter Search Using Charge Signals
Authors:
J. P. Lopez,
S. Ahlen,
J. Battat,
T. Caldwell,
M. Chernicoff,
C. Deaconu,
D. Dujmic,
A. Dushkin,
W. Fedus,
P. Fisher,
F. Golub,
S. Henderson,
A. Inglis,
A. Kaboth,
G. Kohse,
L. Kirsch,
R. Lanza,
A. Lee,
J. Monroe,
H. Ouyang,
T. Sahin,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
H. Wellenstein
, et al. (3 additional authors not shown)
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that the addition of the charge readout analysis to the CCD allows us too obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor of $5.6\times10^{-6}$ for recoils with energies between 40 and 200 keV$_{\mathrm{ee}}$. In addition, requiring coincidence between charge signals and light in the CCD reduces CCD-specific backgrounds by more than two orders of magnitude.
△ Less
Submitted 15 September, 2011;
originally announced September 2011.
-
First Dark Matter Search Results from a Surface Run of the 10-L DMTPC Directional Dark Matter Detector
Authors:
S. Ahlen,
J. B. R. Battat,
T. Caldwell,
C. Deaconu,
D. Dujmic,
W. Fedus,
P. Fisher,
F. Golub,
S. Henderson,
A. Inglis,
A. Kaboth,
G. Kohse,
R. Lanza,
A. Lee,
J. Lopez,
J. Monroe,
T. Sahin,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
H. Wellenstein,
I. Wolfe,
R. Yamamoto,
H. Yegoryan
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) is a low pressure (75 Torr CF4) 10 liter detector capable of measuring the vector direction of nuclear recoils with the goal of directional dark matter detection. In this paper we present the first dark matter limit from DMTPC. In an analysis window of 80-200 keV recoil energy, based on a 35.7 g-day exposure, we set a 90% C.L. upper limit on the spin…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) is a low pressure (75 Torr CF4) 10 liter detector capable of measuring the vector direction of nuclear recoils with the goal of directional dark matter detection. In this paper we present the first dark matter limit from DMTPC. In an analysis window of 80-200 keV recoil energy, based on a 35.7 g-day exposure, we set a 90% C.L. upper limit on the spin-dependent WIMP-proton cross section of 2.0 x 10^{-33} cm^{2} for 115 GeV/c^2 dark matter particle mass.
△ Less
Submitted 9 December, 2010; v1 submitted 15 June, 2010;
originally announced June 2010.