-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Measurement of the 235U(n,f) cross section relative to the 6Li(n,t) and 10B(n,alpha) standards from thermal to 170 keV neutron energy range at n_TOF
Authors:
S. Amaducci,
L. Cosentino,
M. Barbagallo,
N. Colonna,
A. Mengoni,
C. Massimi,
S. Lo Meo,
P. Finocchiaro,
O. Aberle,
J. Andrzejewski,
L. Audouin,
M. Bacak,
J. Balibrea,
F. Bečvář,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Caamaño,
F. Calviño,
M. Calviani,
D. Cano-Ott,
R. Cardella,
A. Casanovas,
F. Cerutti
, et al. (96 additional authors not shown)
Abstract:
The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. This allowed us to make a direct comparison of the reaction yields under the same experimental conditions, and taking into account the forwa…
▽ More
The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. This allowed us to make a direct comparison of the reaction yields under the same experimental conditions, and taking into account the forward/backward emission asymmetry. A hint of an anomaly in the 10÷30 keV neutron energy range had been previously observed in other experiments, indicating a cross section systematically lower by several percent relative to major evaluations. The present results indicate that the evaluated cross section in the 9÷18 keV neutron energy range is indeed overestimated, both in the recent updates of ENDF/B-VIII.0 and of the IAEA reference data. Furthermore, these new high-resolution data confirm the existence of resonance-like structures in the keV neutron energy region. The new, high accuracy results here reported may lead to a reduction of the uncertainty in the 1÷100 keV neutron energy region. Finally, the present data provide additional confidence on the recently re-evaluated cross section integral between 7.8 and 11 eV.
△ Less
Submitted 4 March, 2019; v1 submitted 27 February, 2019;
originally announced February 2019.
-
Experimental setup and procedure for the measurement of the 7Be(n,α)α reaction at n_TOF
Authors:
L. Cosentino,
A. Musumarra,
M. Barbagallo,
A. Pappalardo,
N. Colonna,
L. Damone,
M. Piscopo,
P. Finocchiaro,
E. Maugeri,
S. Heinitz,
D. Schumann,
R. Dressler,
N. Kivel,
O. Aberle,
J. Andrzejewski,
L. Audouin,
M. Ayranov,
M. Bacak,
S. Barros,
J. Balibrea-Correa,
V. Beecares,
F. Becvar,
C. Beinrucker,
E. Berthoumieux,
J. Billowes
, et al. (107 additional authors not shown)
Abstract:
The newly built second experimental area EAR2 of the n_TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the 7Be(n,α) reaction, which represents one of the focal points toward the solution of the…
▽ More
The newly built second experimental area EAR2 of the n_TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the 7Be(n,α) reaction, which represents one of the focal points toward the solution of the cosmological Lithium abundance problem, and whose only measurement, at thermal energy, dates back to 1963. The apparently unsurmountable experimental difficulties stemming from the huge 7Be γ-activity, along with the lack of a suitable neutron beam facility, had so far prevented further measurements. The detection system is subject to considerable radiation damage, but is capable of disentangling the rare reaction signals from the very high background. This newly developed setup could likely be useful also to study other challenging reactions requiring the detectors to be installed directly in the neutron beam.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.