-
New Measurements of the Deuteron to Proton F2 Structure Function Ratio
Authors:
Debaditya Biswas,
Fernando Araiza Gonzalez,
William Henry,
Abishek Karki,
Casey Morean,
Sooriyaarachchilage Nadeeshani,
Abel Sun,
Daniel Abrams,
Zafar Ahmed,
Bashar Aljawrneh,
Sheren Alsalmi,
George Ambrose,
Whitney Armstrong,
Arshak Asaturyan,
Kofi Assumin-Gyimah,
Carlos Ayerbe Gayoso,
Anashe Bandari,
Samip Basnet,
Vladimir Berdnikov,
Hem Bhatt,
Deepak Bhetuwal,
Werner Boeglin,
Peter Bosted,
Edward Brash,
Masroor Bukhari
, et al. (67 additional authors not shown)
Abstract:
Nucleon structure functions, as measured in lepton-nucleon scattering, have historically provided a critical observable in the study of partonic dynamics within the nucleon. However, at very large parton momenta it is both experimentally and theoretically challenging to extract parton distributions due to the probable onset of non-perturbative contributions and the unavailability of high precision…
▽ More
Nucleon structure functions, as measured in lepton-nucleon scattering, have historically provided a critical observable in the study of partonic dynamics within the nucleon. However, at very large parton momenta it is both experimentally and theoretically challenging to extract parton distributions due to the probable onset of non-perturbative contributions and the unavailability of high precision data at critical kinematics. Extraction of the neutron structure and the d-quark distribution have been further challenging due to the necessity of applying nuclear corrections when utilizing scattering data from a deuteron target to extract free neutron structure. However, a program of experiments has been carried out recently at the energy-upgraded Jefferson Lab electron accelerator aimed at significantly reducing the nuclear correction uncertainties on the d-quark distribution function at large partonic momentum. This allows leveraging the vast body of deuterium data covering a large kinematic range to be utilized for d-quark parton distribution function extraction. We present new data from experiment E12-10-002 carried out in Jefferson Lab Hall C on the deuteron to proton cross-section ratio at large BJorken-x. These results significantly improve the precision of existing data, and provide a first look at the expected impact on quark distributions extracted from global parton distribution function fits.
△ Less
Submitted 23 September, 2024;
originally announced September 2024.
-
The Search for the Cosmological Axion -- A New Refined Narrow Mass Window and Detection Scheme
Authors:
Masroor H. S. Bukhari
Abstract:
Based upon a previous axion mass proposal and detection scheme, as well as considering the axion mass ranges suggested by persuasive simulations in recent years, we present a revised axion/ALP search strategy and our calculations, concentrating on a slightly narrower axion mass (and corresponding Compton frequency) window in this report. The sole aim of this study was to provide a pin-point mass v…
▽ More
Based upon a previous axion mass proposal and detection scheme, as well as considering the axion mass ranges suggested by persuasive simulations in recent years, we present a revised axion/ALP search strategy and our calculations, concentrating on a slightly narrower axion mass (and corresponding Compton frequency) window in this report. The sole aim of this study was to provide a pin-point mass value for a resonant cavity detection scheme, and the outcome of calculations presented here reinforces the earlier mass window and the results (slightly different values from our calculations but within the same window) obtained by the calculations and simulations by Kawasaki et al. (2015) and Buschmann et al. (2020). The window comprises the spectral region of 18.99 to 19.01GHz (that falls within the Ku microwave band), with a center frequency of 19.00GHz (+0.1GHz), with equivalence to an axion mass range of 78.6 to 79.6 micro-eV, with the center mass at the value of 78.582 (+5.0) micro-eV, our suggested most likely value for an axionic/ALP field mass, if these fields exist. Our search strategy, as summarized herewith, is based upon the assumption that the dark matter that exists in the current epoch of our physical universe is dominated by axions and thus the local observable axion density is the density of the light cold dark matter, permeating our local neighborhood (mainly in the Milky Way galactic halo). Some ideas and the design of an experiment, based upon the inverse Primakoff effect, and built around a Josephson Parametric Amplifier and Resonant Tunneling Diode combination installed in a resonant RF cavity, are also some possibly novel ideas, as introduced in this report.
△ Less
Submitted 1 October, 2024; v1 submitted 18 August, 2024;
originally announced August 2024.
-
Design of the ECCE Detector for the Electron Ion Collider
Authors:
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin,
R. Capobianco
, et al. (259 additional authors not shown)
Abstract:
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent track…
▽ More
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. This detector concept has been selected to be the basis for the EIC project detector.
△ Less
Submitted 20 July, 2024; v1 submitted 6 September, 2022;
originally announced September 2022.
-
ECCE unpolarized TMD measurements
Authors:
R. Seidl,
A. Vladimirov,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari
, et al. (258 additional authors not shown)
Abstract:
We performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS…
▽ More
We performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables $x$ and $Q^2$, as well as the semi-inclusive variables $z$, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and $P_T$, which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb$^{-1}$ and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
ECCE Sensitivity Studies for Single Hadron Transverse Single Spin Asymmetry Measurements
Authors:
R. Seidl,
A. Vladimirov,
D. Pitonyak,
A. Prokudin,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks
, et al. (260 additional authors not shown)
Abstract:
We performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in {\sc…
▽ More
We performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in {\sc pythia}6 and {\sc geant}4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably $Q^2 > 1 $ GeV$^2$, and cover the $x$ range from $10^{-4}$ to $1$. The single spin asymmetries were extracted as a function of $x$ and $Q^2$, as well as the semi-inclusive variables $z$, and $P_T$. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. The initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and $e^+e^-$ annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb$^{-1}$ and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. The impact is found to be comparable to that obtained with the parameterized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
Open Heavy Flavor Studies for the ECCE Detector at the Electron Ion Collider
Authors:
X. Li,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann,
M. H. S. Bukhari,
A. Bylinkin
, et al. (262 additional authors not shown)
Abstract:
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will…
▽ More
The ECCE detector has been recommended as the selected reference detector for the future Electron-Ion Collider (EIC). A series of simulation studies have been carried out to validate the physics feasibility of the ECCE detector. In this paper, detailed studies of heavy flavor hadron and jet reconstruction and physics projections with the ECCE detector performance and different magnet options will be presented. The ECCE detector has enabled precise EIC heavy flavor hadron and jet measurements with a broad kinematic coverage. These proposed heavy flavor measurements will help systematically study the hadronization process in vacuum and nuclear medium especially in the underexplored kinematic region.
△ Less
Submitted 23 July, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Design and Simulated Performance of Calorimetry Systems for the ECCE Detector at the Electron Ion Collider
Authors:
F. Bock,
N. Schmidt,
P. K. Wang,
N. Santiesteban,
T. Horn,
J. Huang,
J. Lajoie,
C. Munoz Camacho,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
W. Boeglin,
M. Borysova,
E. Brash
, et al. (263 additional authors not shown)
Abstract:
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key…
▽ More
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapdity range from -3.7 to 3.8 and two hadronic calorimeters. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.
△ Less
Submitted 19 July, 2022;
originally announced July 2022.
-
AI-assisted Optimization of the ECCE Tracking System at the Electron Ion Collider
Authors:
C. Fanelli,
Z. Papandreou,
K. Suresh,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
J. C. Bernauer,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash,
P. Brindza,
W. J. Briscoe,
M. Brooks,
S. Bueltmann
, et al. (258 additional authors not shown)
Abstract:
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to…
▽ More
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the "glue" that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.
△ Less
Submitted 19 May, 2022; v1 submitted 18 May, 2022;
originally announced May 2022.
-
Scientific Computing Plan for the ECCE Detector at the Electron Ion Collider
Authors:
J. C. Bernauer,
C. T. Dean,
C. Fanelli,
J. Huang,
K. Kauder,
D. Lawrence,
J. D. Osborn,
C. Paus,
J. K. Adkins,
Y. Akiba,
A. Albataineh,
M. Amaryan,
I. C. Arsene,
C. Ayerbe Gayoso,
J. Bae,
X. Bai,
M. D. Baker,
M. Bashkanov,
R. Bellwied,
F. Benmokhtar,
V. Berdnikov,
F. Bock,
W. Boeglin,
M. Borysova,
E. Brash
, et al. (256 additional authors not shown)
Abstract:
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing thes…
▽ More
The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing these challenges in the process of producing a complete detector proposal based upon detailed detector and physics simulations. In this document, the software and computing efforts to produce this proposal are discussed; furthermore, the computing and software model and resources required for the future of ECCE are described.
△ Less
Submitted 17 May, 2022;
originally announced May 2022.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
Ruling out color transparency in quasi-elastic $^{12}$C(e,e'p) up to $Q^2$ of 14.2 (GeV/c)$^2$
Authors:
D. Bhetuwal,
J. Matter,
H. Szumila-Vance,
M. L. Kabir,
D. Dutta,
R. Ent,
D. Abrams,
Z. Ahmed,
B. Aljawrneh,
S. Alsalmi,
R. Ambrose,
D. Androic,
W. Armstrong,
A. Asaturyan,
K. Assumin-Gyimah,
C. Ayerbe Gayoso,
A. Bandari,
S. Basnet,
V. Berdnikov,
H. Bhatt,
D. Biswas,
W. U. Boeglin,
P. Bosted,
E. Brash,
M. H. S. Bukhari
, et al. (65 additional authors not shown)
Abstract:
Quasielastic $^{12}$C$(e,e'p)$ scattering was measured at space-like 4-momentum transfer squared $Q^2$~=~8, 9.4, 11.4, and 14.2 (GeV/c)$^2$, the highest ever achieved to date. Nuclear transparency for this reaction was extracted by comparing the measured yield to that expected from a plane-wave impulse approximation calculation without any final state interactions. The measured transparency was co…
▽ More
Quasielastic $^{12}$C$(e,e'p)$ scattering was measured at space-like 4-momentum transfer squared $Q^2$~=~8, 9.4, 11.4, and 14.2 (GeV/c)$^2$, the highest ever achieved to date. Nuclear transparency for this reaction was extracted by comparing the measured yield to that expected from a plane-wave impulse approximation calculation without any final state interactions. The measured transparency was consistent with no $Q^2$ dependence, up to proton momenta of 8.5~GeV/c, ruling out the quantum chromodynamics effect of color transparency at the measured $Q^2$ scales in exclusive $(e,e'p)$ reactions. These results impose strict constraints on models of color transparency for protons.
△ Less
Submitted 1 March, 2021; v1 submitted 1 November, 2020;
originally announced November 2020.
-
Light Dark Matter Search and Spectroscopy -- Brief Review and An Experimental Technique
Authors:
Masroor H. S. Bukhari
Abstract:
A brief review of light dark matter particles and their spectroscopy is presented, specifically aimed at understanding the interaction mechanisms of axion and Axion-Like Particles (ALPs) with matter and an interim proposal and some ideas for possible detection of these evasive particles. In order to venture into the highly challenging spectral regions and extremely weak signals involved with these…
▽ More
A brief review of light dark matter particles and their spectroscopy is presented, specifically aimed at understanding the interaction mechanisms of axion and Axion-Like Particles (ALPs) with matter and an interim proposal and some ideas for possible detection of these evasive particles. In order to venture into the highly challenging spectral regions and extremely weak signals involved with these searches (especially for the DFSZ axions), a different scheme is proposed departing from the conventional resonant cavity mass scan and heterodyne detection methods. We aim to look for a fixed mass axionic field and concentrate our search at the corresponding resonant frequency and its higher harmonics using a simple phase-sensitive dc detection method, which could possibly be helpful in substantially reducing both the hardware, experiment complexities and long run times. The probable mass range suggested in the model presented here begins with 22.5microeV, corresponding to a resonant frequency of 5.4GHz, going all the way to its two multiples of 90 and 112.5microeV (corresponding to 24.3 and 27.0GHz frequencies, respectively), with high probability of finding an axion or ALP around these mass values. We present a comprehensive measurement strategy and spectroscopy technique based upon this model which revolves around a three-stage amplification and phase-sensitive detection scheme to maximize and detect a resonant axionic coupling to the U(1) fields under a coherent Primakoff effect interaction. The feasibility of proposed scheme is demonstrated with some calculations, simulations and preliminary tests. This experimental technique and ideas reported here have significant potential to be developed into an extremely sensitive narrow-range dark matter axion/ALP spectroscopy experiment.
△ Less
Submitted 30 March, 2019;
originally announced April 2019.
-
Dark Sectors 2016 Workshop: Community Report
Authors:
Jim Alexander,
Marco Battaglieri,
Bertrand Echenard,
Rouven Essig,
Matthew Graham,
Eder Izaguirre,
John Jaros,
Gordan Krnjaic,
Jeremy Mardon,
David Morrissey,
Tim Nelson,
Maxim Perelstein,
Matt Pyle,
Adam Ritz,
Philip Schuster,
Brian Shuve,
Natalia Toro,
Richard G Van De Water,
Daniel Akerib,
Haipeng An,
Konrad Aniol,
Isaac J. Arnquist,
David M. Asner,
Henning O. Back,
Keith Baker
, et al. (179 additional authors not shown)
Abstract:
This report, based on the Dark Sectors workshop at SLAC in April 2016, summarizes the scientific importance of searches for dark sector dark matter and forces at masses beneath the weak-scale, the status of this broad international field, the important milestones motivating future exploration, and promising experimental opportunities to reach these milestones over the next 5-10 years.
This report, based on the Dark Sectors workshop at SLAC in April 2016, summarizes the scientific importance of searches for dark sector dark matter and forces at masses beneath the weak-scale, the status of this broad international field, the important milestones motivating future exploration, and promising experimental opportunities to reach these milestones over the next 5-10 years.
△ Less
Submitted 30 August, 2016;
originally announced August 2016.
-
An Experiment and Detection Scheme for Cavity-based Cold Dark Matter Searches
Authors:
M. H. S. Bukhari,
Z. H. Shah
Abstract:
A resonance detection scheme and some useful ideas for cavity-based searches of light cold dark matter particles (such as axions) are presented, as an effort to aid in the on-going endeavors in this direction as well as for future experiments, especially in possibly developing a table-top experiment. The scheme is based on our idea of a resonant detector, incorporating an integrated Tunnel Diode (…
▽ More
A resonance detection scheme and some useful ideas for cavity-based searches of light cold dark matter particles (such as axions) are presented, as an effort to aid in the on-going endeavors in this direction as well as for future experiments, especially in possibly developing a table-top experiment. The scheme is based on our idea of a resonant detector, incorporating an integrated Tunnel Diode (TD) and a GaAs HEMT/HFET (High Electron Mobility Transistor/Heterogenous FET) transistor amplifier, weakly coupled to a cavity in a strong transverse magnetic field. The TD-amplifier combination is suggested as a sensitive and simple technique to facilitate resonance detection within the cavity while maintaining excellent noise performance, whereas our proposed Halbach magnet array could serve as a low-noise and permanent solution replacing the conventional electromagnets scheme. We present some preliminary test results which demonstrate resonance detection from simulated test signals in a small optimal axion mass range with superior Signal-to-Noise Ratios (SNR). Our suggested design also contains an overview of a simpler on-resonance dc signal read-out scheme replacing the complicated heterodyne readout. We believe that all these factors and our propositions could possibly improve or at least simplify the resonance detection and read-out in cavity-based DM particle detection searches (and other spectroscopy applications) and reduce the complications (and associated costs), in addition to reducing the electromagnetic interference and background.
△ Less
Submitted 8 February, 2017; v1 submitted 23 April, 2016;
originally announced April 2016.