The calibration system for the photomultiplier array of the SNO+ experiment
Authors:
R. Alves,
S. Andringa,
S. Bradbury,
J. Carvalho,
D. Chauhan,
K. Clark,
I. Coulter,
F. Descamps,
E. Falk,
L. Gurriana,
C. Kraus,
G. Lefeuvre,
A. Maio,
J. Maneira,
M. Mottram,
S. Peeters,
J. Rose,
L. Seabra,
J. Sinclair,
P. Skensved,
J. Waterfield,
R. White,
J. R. Wilson
Abstract:
A light injection system using LEDs and optical fibres was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. Large volume, non-segmented, low-background detectors for rare event physics, such as the multi-purpose SNO+ experiment, need a calibration system that allow an accurate and regular measurement of the performance parameters of their p…
▽ More
A light injection system using LEDs and optical fibres was designed for the calibration and monitoring of the photomultiplier array of the SNO+ experiment at SNOLAB. Large volume, non-segmented, low-background detectors for rare event physics, such as the multi-purpose SNO+ experiment, need a calibration system that allow an accurate and regular measurement of the performance parameters of their photomultiplier arrays, while minimising the risk of radioactivity ingress. The design implemented for SNO+ uses a set of optical fibres to inject light pulses from external LEDs into the detector. The design, fabrication and installation of this light injection system, as well as the first commissioning tests, are described in this paper. Monte Carlo simulations were compared with the commissioning test results, confirming that the system meets the performance requirements.
△ Less
Submitted 16 January, 2015; v1 submitted 18 November, 2014;
originally announced November 2014.
VERITAS Deep Observations of the Dwarf Spheroidal Galaxy Segue 1
Authors:
E. Aliu,
S. Archambault,
T. Arlen,
T. Aune,
M. Beilicke,
W. Benbow,
A. Bouvier,
S. M. Bradbury,
J. H. Buckley,
V. Bugaev,
K. Byrum,
A. Cannon,
A. Cesarini,
J. L. Christiansen,
L. Ciupik,
E. Collins-Hughes,
M. P. Connolly,
W. Cui,
G. Decerprit,
R. Dickherber,
J. Dumm,
M. Errando,
A. Falcone,
Q. Feng,
F. Ferrer
, et al. (68 additional authors not shown)
Abstract:
The VERITAS array of Cherenkov telescopes has carried out a deep observational program on the nearby dwarf spheroidal galaxy Segue 1. We report on the results of nearly 48 hours of good quality selected data, taken between January 2010 and May 2011. No significant $γ$-ray emission is detected at the nominal position of Segue 1, and upper limits on the integrated flux are derived. According to rece…
▽ More
The VERITAS array of Cherenkov telescopes has carried out a deep observational program on the nearby dwarf spheroidal galaxy Segue 1. We report on the results of nearly 48 hours of good quality selected data, taken between January 2010 and May 2011. No significant $γ$-ray emission is detected at the nominal position of Segue 1, and upper limits on the integrated flux are derived. According to recent studies, Segue 1 is the most dark matter-dominated dwarf spheroidal galaxy currently known. We derive stringent bounds on various annihilating and decaying dark matter particle models. The upper limits on the velocity-weighted annihilation cross-section are $\mathrm{<σv >^{95% CL} \lesssim 10^{-23} cm^{3} s^{-1}}$, improving our limits from previous observations of dwarf spheroidal galaxies by at least a factor of two for dark matter particle masses $\mathrm{m_χ\gtrsim 300 GeV}$. The lower limits on the decay lifetime are at the level of $\mathrm{τ^{95% CL} \gtrsim 10^{24} s}$. Finally, we address the interpretation of the cosmic ray lepton anomalies measured by ATIC and PAMELA in terms of dark matter annihilation, and show that the VERITAS observations of Segue 1 disfavor such a scenario.
△ Less
Submitted 7 July, 2015; v1 submitted 9 February, 2012;
originally announced February 2012.