Skip to main content

Showing 1–6 of 6 results for author: Bogdan, M

Searching in archive hep-ex. Search in all archives.
.
  1. arXiv:2210.12070  [pdf, other

    hep-ex astro-ph.IM nucl-ex physics.ins-det

    The DAMIC-M Experiment: Status and First Results

    Authors: I. Arnquist, N. Avalos, P. Bailly, D. Baxter, X. Bertou, M. Bogdan, C. Bourgeois, J. Brandt, A. Cadiou, N. Castelló-Mor, A. E. Chavarria, M. Conde, N. J. Corso, J. Cortabitarte Gutiérrez, J. Cuevas-Zepeda, A. Dastgheibi-Fard, C. De Dominicis, O. Deligny, R. Desani, M. Dhellot, J-J. Dormard, J. Duarte-Campderros, E. Estrada, D. Florin, N. Gadola , et al. (47 additional authors not shown)

    Abstract: The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV… ▽ More

    Submitted 25 November, 2022; v1 submitted 11 October, 2022; originally announced October 2022.

    Comments: 10 pages, 6 figures, Submission to SciPost Physics Proceedings: 14th International Conference on Identification of Dark Matter (IDM) 2022

  2. arXiv:1607.02395  [pdf, other

    physics.ins-det hep-ex

    A Modular Data Acquisition System using the 10 GSa/s PSEC4 Waveform Recording Chip

    Authors: M. Bogdan, E. Oberla, H. J. Frisch, M. Wetstein

    Abstract: We describe a modular multi-channel data acquisition system based on the 5-15 Gigasample-per-second waveform-recording PSEC4 chip. The system architecture incorporates two levels of hardware with FPGA-embedded system control and in-line data processing. The front-end unit is a 30-channel circuit board that holds five PSEC4 ASICs, a clock jitter cleaner, and a control FPGA. The analog bandwidth of… ▽ More

    Submitted 8 July, 2016; originally announced July 2016.

    Comments: 3 pages, 4 figures, proceedings for the 2016 IEEE-NPSS Real-Time conference in Padova

  3. arXiv:1603.01843  [pdf, other

    physics.ins-det hep-ex

    A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration

    Authors: Bernhard W. Adams, Klaus Attenkofer, Mircea Bogdan, Karen Byrum, Andrey Elagin, Jeffrey W. Elam, Henry J. Frisch, Jean-Francois Genat, Herve Grabas, Joseph Gregar, Elaine Hahn, Mary Heintz, Zinetula Insepov, Valentin Ivanov, Sharon Jelinsky, Slade Jokely, Sun Wu Lee, Anil. U. Mane, Jason McPhate, Michael J. Minot, Pavel Murat, Kurtis Nishimura, Richard Northrop, Razib Obaid, Eric Oberla , et al. (16 additional authors not shown)

    Abstract: The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$,… ▽ More

    Submitted 6 March, 2016; originally announced March 2016.

  4. arXiv:1406.3907  [pdf, other

    physics.ins-det hep-ex

    The Data Acquisition System for the KOTO Experiment

    Authors: Yasuyuki Sugiyama, Jia Xu, Monica Tecchio, Nikola Whallon, Duncan McFarland, Jiasen Ma, Manabu Togawa, Yasuhisa Tajima, Mircea Bogdan, Jon Ameel, Myron Campbell, Yau Wai Wah, Joseph Comfort, Taku Yamanaka

    Abstract: We developed and built a new system of readout and trigger electronics, based on the waveform digitization and pipeline readout, for the KOTO experiment at J-PARC, Japan. KOTO aims at observing the rare kaon decay $K_{L}\rightarrowπ^{0}ν\barν$. A total of 4000 readout channels from various detector subsystems are digitized by 14-bit 125-MHz ADC modules equipped with a 10-pole Bessel filter in orde… ▽ More

    Submitted 16 June, 2014; originally announced June 2014.

    Comments: 5 pages,12 figures, Transactions on Nuclear Science, Proceedings of the 19th Real Time Conference, Preprint

  5. arXiv:1307.2232   

    astro-ph.HE astro-ph.IM hep-ex

    CTA contributions to the 33rd International Cosmic Ray Conference (ICRC2013)

    Authors: The CTA Consortium, :, O. Abril, B. S. Acharya, M. Actis, G. Agnetta, J. A. Aguilar, F. Aharonian, M. Ajello, A. Akhperjanian, M. Alcubierre, J. Aleksic, R. Alfaro, E. Aliu, A. J. Allafort, D. Allan, I. Allekotte, R. Aloisio, E. Amato, G. Ambrosi, M. Ambrosio, J. Anderson, E. O. Angüner, L. A. Antonelli, V. Antonuccio , et al. (1082 additional authors not shown)

    Abstract: Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil

    Submitted 29 July, 2013; v1 submitted 8 July, 2013; originally announced July 2013.

    Comments: Index of CTA conference proceedings at the ICRC2013, Rio de Janeiro (Brazil). v1: placeholder with no arXiv links yet, to be replaced once individual contributions have been all submitted. v2: final with arXiv links to all CTA contributions and full author list

  6. arXiv:physics/0502062  [pdf, ps, other

    physics.ins-det hep-ex

    A 96-Channel FPGA-based Time-to-Digital Converter

    Authors: Mircea Bogdan, Henry Frisch, Mary Heintz, Alexander Paramonov, Harold Sanders, Steve Chappa, Robert DeMaat, Rod Klein, Ting Miao, Peter Wilson, Thomas J. Phillips

    Abstract: We describe an FPGA-based, 96-channel, time-to-digital converter (TDC) intended for use with the Central Outer Tracker (COT) in the CDF Experiment at the Fermilab Tevatron. The COT system is digitized and read out by 315 TDC cards, each serving 96 wires of the chamber. The TDC is physically configured as a 9U VME card. The functionality is almost entirely programmed in firmware in two Altera Str… ▽ More

    Submitted 11 February, 2005; originally announced February 2005.

    Comments: 32 pages, 13 figures

    Report number: EFI-04-42