-
First Results on the Search for Lepton Number Violating Neutrinoless Double Beta Decay with the LEGEND-200 Experiment
Authors:
H. Acharya,
N. Ackermann,
M. Agostini,
A. Alexander,
C. Andreoiu,
G. R. Araujo,
F. T. Avignone III,
M. Babicz,
W. Bae,
A. Bakalyarov,
M. Balata,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
L. Baudis,
C. Bauer,
E. Bernieri,
L. Bezrukov,
K. H. Bhimani,
V. Biancacci,
E. Blalock,
S. J. Borden,
G. Borghi,
F. Borra,
B. Bos
, et al. (234 additional authors not shown)
Abstract:
The LEGEND collaboration is searching for neutrinoless double beta ($0νββ$) decay by operating high-purity germanium detectors enriched in $^{76}$Ge in a low-background liquid argon environment. Building on key technological innovations from GERDA and the MAJORANA DEMONSTRATOR, LEGEND-200 has performed a first $0νββ$ decay search based on 61 kg yr of data. Over half of this exposure comes from our…
▽ More
The LEGEND collaboration is searching for neutrinoless double beta ($0νββ$) decay by operating high-purity germanium detectors enriched in $^{76}$Ge in a low-background liquid argon environment. Building on key technological innovations from GERDA and the MAJORANA DEMONSTRATOR, LEGEND-200 has performed a first $0νββ$ decay search based on 61 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of $0.5^{+0.3}_{-0.2}$ cts/(keV ton yr) in the $0νββ$ decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of $2.8 \times 10^{26}$ yr on the half-life of $0νββ$ decay, reveals no evidence for a signal and sets a new observed lower limit at $T^{0ν}_{1/2} > 1.9 \times 10^{26}$ yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range $m_{ββ} < 75-200$ meV, depending on the adopted nuclear matrix element.
△ Less
Submitted 16 June, 2025; v1 submitted 15 May, 2025;
originally announced May 2025.
-
Constraints on the decay of $^{180m}$Ta
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (34 additional authors not shown)
Abstract:
$^{180m}$Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known $β…
▽ More
$^{180m}$Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known $β$ and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the MAJORANA DEMONSTRATOR, an experimental search for the neutrinoless double-beta decay of $^{76}$Ge using an array of high-purity germanium detectors, to search for the decay of $^{180m}$Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the $^{180m}$Ta half-life on the different decay channels. With new limits up to 1.5 x $10^{19}$ years, we improved existing limits by one to two orders of magnitude. This result is the most sensitive search for a single $β$ and electron capture decay ever achieved.
△ Less
Submitted 2 June, 2023;
originally announced June 2023.
-
Final Result of the MAJORANA DEMONSTRATOR's Search for Neutrinoless Double-$β$ Decay in $^{76}$Ge
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (35 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR searched for neutrinoless double-$β$ decay ($0νββ$) of $^{76}$Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-background shield. The arrays operated with up to 40.4 kg of detectors (27.2 kg enriched to $\sim$88\% in $^{76}$Ge). From these measurements, the DEMONSTRATOR has accumulated 64.5 kg yr of enriched active exposure. With a…
▽ More
The MAJORANA DEMONSTRATOR searched for neutrinoless double-$β$ decay ($0νββ$) of $^{76}$Ge using modular arrays of high-purity Ge detectors operated in vacuum cryostats in a low-background shield. The arrays operated with up to 40.4 kg of detectors (27.2 kg enriched to $\sim$88\% in $^{76}$Ge). From these measurements, the DEMONSTRATOR has accumulated 64.5 kg yr of enriched active exposure. With a world-leading energy resolution of 2.52 keV FWHM at the 2039 keV $Q_{ββ}$ (0.12\%), we set a half-life limit of $0νββ$ in $^{76}$Ge at $T_{1/2}>8.3\times10^{25}$ yr (90\% C.L.). This provides a range of upper limits on $m_{ββ}$ of $(113-269)$ meV (90\% C.L.), depending on the choice of nuclear matrix elements.
△ Less
Submitted 10 February, 2023; v1 submitted 15 July, 2022;
originally announced July 2022.
-
Exotic dark matter search with the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (34 additional authors not shown)
Abstract:
With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos, $ν_s \rightarrow ν_a$. We report n…
▽ More
With excellent energy resolution and ultra-low level radiogenic backgrounds, the high-purity germanium detectors in the Majorana Demonstrator enable searches for several classes of exotic dark matter (DM) models. In this work, we report new experimental limits on keV-scale sterile neutrino DM via the transition magnetic moment from conversion to active neutrinos, $ν_s \rightarrow ν_a$. We report new limits on fermionic dark matter absorption ($χ+ A \rightarrow ν+ A$) and sub-GeV DM-nucleus 3$\rightarrow$2 scattering ($χ+ χ+ A \rightarrow φ+ A$), and new exclusion limits for bosonic dark matter (axionlike particles and dark photons). These searches utilize the (1--100)-keV low energy region of a 37.5-kg y exposure collected by the Demonstrator between May 2016 and November 2019, using a set of $^{76}$Ge-enriched detectors whose surface exposure time was carefully controlled, resulting in extremely low levels of cosmogenic activation.
△ Less
Submitted 26 July, 2024; v1 submitted 21 June, 2022;
originally announced June 2022.
-
Search for solar axions via axion-photon coupling with the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe
, et al. (33 additional authors not shown)
Abstract:
Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in solid state detection experiments with enhancements due to coherent Primakoff-Bragg scattering. The Majorana Demonstrator experiment has searched for solar axions with a set of $^{76}$Ge-enriched high purity germanium dete…
▽ More
Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in solid state detection experiments with enhancements due to coherent Primakoff-Bragg scattering. The Majorana Demonstrator experiment has searched for solar axions with a set of $^{76}$Ge-enriched high purity germanium detectors using a 33 kg-yr exposure collected between Jan. 2017 and Nov. 2019. A temporal-energy analysis gives a new limit on the axion-photon coupling as $g_{aγ}<1.45\times 10^{-9}$ GeV$^{-1}$ (95% C.I.) for axions with mass up to 100 eV/$c^2$. This improves laboratory-based limits between about 1 eV/$c^2$ and 100 eV/$c^2$.
△ Less
Submitted 22 August, 2022; v1 submitted 12 June, 2022;
originally announced June 2022.
-
Experimental study of 13C(α,n)16O reactions in the Majorana Demonstrator calibration data
Authors:
MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimate…
▽ More
Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129-keV $γ$-rays emitted from the excited $^{16}$O states that are populated when the incoming $α$-particles exceed the reaction Q-value. Thanks to the excellent energy performance of the \textsc{Demonstrator}'s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by \textsc{Geant4} simulations, a comparison between the observed 6129-keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent, albeit with large statistical uncertainties. This agreement provides support for background projections from ($α,n$)-reactions in future double-beta decay search efforts.
△ Less
Submitted 11 July, 2022; v1 submitted 27 March, 2022;
originally announced March 2022.
-
Search for charge nonconservation and Pauli exclusion principle violation with the Majorana Demonstrator
Authors:
MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
K. H. Bhimani,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detec…
▽ More
Charge conservation and the Pauli exclusion principle result from fundamental symmetries in the standard model of particle physics, and are typically taken as axiomatic. High-precision tests for small violations of these symmetries could point to new physics. Here we consider three models for violation of these processes, which would produce detectable ionization in the high-purity germanium detectors of the \MJD\ experiment. Using a 37.5 kg-yr exposure, we report a lower limit on the electron mean lifetime, improving the previous best limit for the $e \rightarrow ν_e \overline{ν_e} ν_e$ decay channel by more than an order of magnitude. We also present searches for two types of violation of the Pauli exclusion principle, setting limits on the probability of an electron to be found in a symmetric quantum state.
△ Less
Submitted 25 February, 2025; v1 submitted 3 March, 2022;
originally announced March 2022.
-
The MAJORANA DEMONSTRATOR Readout Electronics System
Authors:
N. Abgrall,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
K. H. Bhimani,
B. Bos,
A. W. Bradley,
T. H. Burritt,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
R. J. Cooper,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko
, et al. (54 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper prov…
▽ More
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.
△ Less
Submitted 23 February, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.