Skip to main content

Showing 1–5 of 5 results for author: Agramunt, J

Searching in archive hep-ex. Search in all archives.
.
  1. Long-term evolution of the neutron rate at the Canfranc Underground Laboratory

    Authors: S. E. A. Orrigo, J. L. Tain, N. Mont-Geli, A. Tarifeño-Saldivia, L. M. Fraile, M. Grieger, J. Agramunt, A. Algora, D. Bemmerer, F. Calviño, G. Cortés, A. De Blas, I. Dillmann, A. Domínguez Bugarín, R. García, E. Nacher, A. Tolosa-Delgado

    Abstract: We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign was performed employing the High Efficiency Neutron Spectrometry Array (HENSA) mounted in Hall A and lasted 412 live days. The present study is the first long-t… ▽ More

    Submitted 29 August, 2022; v1 submitted 29 April, 2022; originally announced April 2022.

    Comments: 12 pages, 5 figures, 2 tables

    Journal ref: Eur. Phys. J. C 82, 814 (2022)

  2. Measurement of the neutron flux at the Canfranc Underground Laboratory with HENSA

    Authors: S. E. A. Orrigo, J. L. Tain, N. Mont-Geli, A. Tarifeño-Saldivia, L. M. Fraile, M. Grieger, J. Agramunt, A. Algora, D. Bemmerer, F. Calviño, G. Cortés, A. De Blas, I. Dillmann, A. Domínguez Bugarín, R. García, E. Nacher, A. Tolosa

    Abstract: We have performed a long-term measurement of the neutron flux with the High Efficiency Neutron Spectrometry Array HENSA in the Hall A of the Canfranc Underground Laboratory. The Hall A measurement campaign lasted from October 2019 to March 2021, demonstrating an excellent stability of the HENSA setup. Preliminary results on the neutron flux from this campaign are presented for the first time. In P… ▽ More

    Submitted 17 November, 2021; originally announced November 2021.

    Comments: Proceedings of the 17th International Conference on Topics in Astroparticle and Underground Physics (TAUP 2021)

  3. arXiv:2006.02696  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Neutron flux and spectrum in the Dresden Felsenkeller underground facility studied by moderated $^3$He counters

    Authors: M. Grieger, T. Hensel, J. Agramunt, D. Bemmerer, D. Degering, I. Dillmann, L. M. Fraile, D. Jordan, U. Köster, M. Marta, S. E. Müller, T. Szücs, J. L. Taín, K. Zuber

    Abstract: Ambient neutrons may cause significant background for underground experiments. Therefore, it is necessary to investigate their flux and energy spectrum in order to devise a proper shielding. Here, two sets of altogether ten moderated $^3$He neutron counters are used for a detailed study of the ambient neutron background in tunnel IV of the Felsenkeller facility, underground below 45 meters of rock… ▽ More

    Submitted 19 June, 2020; v1 submitted 4 June, 2020; originally announced June 2020.

    Comments: 10 figures, 4 tables; to be published in Phys. Rev. D

    Journal ref: Phys. Rev. D 101, 123027 (2020)

  4. Total Absorption Spectroscopy Study of $^{92}$Rb Decay: A Major Contributor to Reactor Antineutrino Spectrum Shape

    Authors: A. -A. Zakari-Issoufou, M. Fallot, A. Porta, A. Algora, J. L. Tain, E. Valencia, S. Rice, V. M Bui, S. Cormon, M. Estienne, J. Agramunt, J. Äystö, M. Bowry, J. A. Briz, R. Caballero-Folch, D. Cano-Ott, A. Cucoanes, V. -V. Elomaa, T. Eronen, E. Estévez, G. F. Farrelly, A. R. Garcia, W. Gelletly, M. B Gomez-Hornillos, V. Gorlychev , et al. (22 additional authors not shown)

    Abstract: The antineutrino spectra measured in recent experiments at reactors are inconsistent with calculations based on the conversion of integral beta spectra recorded at the ILL reactor. $^{92}$Rb makes the dominant contribution to the reactor spectrum in the 5-8 MeV range but its decay properties are in question. We have studied $^{92}$Rb decay with total absorption spectroscopy. Previously unobserved… ▽ More

    Submitted 24 September, 2015; v1 submitted 22 April, 2015; originally announced April 2015.

    Comments: 6 pages, 3 figures

    Journal ref: Phys. Rev. Lett. 115, 102503 (2015)

  5. arXiv:1201.2018  [pdf, other

    physics.ins-det hep-ex

    SiPMs coated with TPB : coating protocol and characterization for NEXT

    Authors: V. Álvarez, J. Agramunt, M. Ball, M. Batallé, J. Bayarri, F. I. G. Borges, H. Bolink, H. Brine, S. Cárcel, J. M. Carmona, J. Castel, J. M. Catalá, S. Cebrián, A. Cervera, D. Chan, C. A. N. Conde, T. Dafni, T. H. V. T. Dias, J. Díaz, R. Esteve, P. Evtoukhovitch, J. Ferrando, L. M. P. Fernandes, P. Ferrario, A. L. Ferreira , et al. (69 additional authors not shown)

    Abstract: Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs off… ▽ More

    Submitted 10 January, 2012; originally announced January 2012.

    Comments: Submitted to the Journal of Instrumentation on december 26th 2011

    Journal ref: JINST 7 (2012) P02010