-
Long-term evolution of the neutron rate at the Canfranc Underground Laboratory
Authors:
S. E. A. Orrigo,
J. L. Tain,
N. Mont-Geli,
A. Tarifeño-Saldivia,
L. M. Fraile,
M. Grieger,
J. Agramunt,
A. Algora,
D. Bemmerer,
F. Calviño,
G. Cortés,
A. De Blas,
I. Dillmann,
A. Domínguez Bugarín,
R. García,
E. Nacher,
A. Tolosa-Delgado
Abstract:
We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign was performed employing the High Efficiency Neutron Spectrometry Array (HENSA) mounted in Hall A and lasted 412 live days. The present study is the first long-t…
▽ More
We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign was performed employing the High Efficiency Neutron Spectrometry Array (HENSA) mounted in Hall A and lasted 412 live days. The present study is the first long-term measurement of the neutron rate with sensitivity over a wide range of neutron energies (from thermal up to 0.1 GeV and beyond) performed in any underground laboratory so far. Data on the environmental variables inside the experimental hall (radon concentration, air temperature, air pressure and humidity) were also acquired during all the measurement campaign. We have investigated for the first time the evolution of the neutron rate for different energies of the neutrons and its correlation with the ambient variables.
△ Less
Submitted 29 August, 2022; v1 submitted 29 April, 2022;
originally announced April 2022.
-
Measurement of the neutron flux at the Canfranc Underground Laboratory with HENSA
Authors:
S. E. A. Orrigo,
J. L. Tain,
N. Mont-Geli,
A. Tarifeño-Saldivia,
L. M. Fraile,
M. Grieger,
J. Agramunt,
A. Algora,
D. Bemmerer,
F. Calviño,
G. Cortés,
A. De Blas,
I. Dillmann,
A. Domínguez Bugarín,
R. García,
E. Nacher,
A. Tolosa
Abstract:
We have performed a long-term measurement of the neutron flux with the High Efficiency Neutron Spectrometry Array HENSA in the Hall A of the Canfranc Underground Laboratory. The Hall A measurement campaign lasted from October 2019 to March 2021, demonstrating an excellent stability of the HENSA setup. Preliminary results on the neutron flux from this campaign are presented for the first time. In P…
▽ More
We have performed a long-term measurement of the neutron flux with the High Efficiency Neutron Spectrometry Array HENSA in the Hall A of the Canfranc Underground Laboratory. The Hall A measurement campaign lasted from October 2019 to March 2021, demonstrating an excellent stability of the HENSA setup. Preliminary results on the neutron flux from this campaign are presented for the first time. In Phase 1 (113 live days) a total neutron flux of 1.66(2) $\times$10$^{-5}$ cm$^{-2}$ s$^{-1}$ is obtained. Our results are in good agreement with those from our previous shorter measurement where a reduced experimental setup was employed.
△ Less
Submitted 17 November, 2021;
originally announced November 2021.
-
Neutron flux and spectrum in the Dresden Felsenkeller underground facility studied by moderated $^3$He counters
Authors:
M. Grieger,
T. Hensel,
J. Agramunt,
D. Bemmerer,
D. Degering,
I. Dillmann,
L. M. Fraile,
D. Jordan,
U. Köster,
M. Marta,
S. E. Müller,
T. Szücs,
J. L. Taín,
K. Zuber
Abstract:
Ambient neutrons may cause significant background for underground experiments. Therefore, it is necessary to investigate their flux and energy spectrum in order to devise a proper shielding. Here, two sets of altogether ten moderated $^3$He neutron counters are used for a detailed study of the ambient neutron background in tunnel IV of the Felsenkeller facility, underground below 45 meters of rock…
▽ More
Ambient neutrons may cause significant background for underground experiments. Therefore, it is necessary to investigate their flux and energy spectrum in order to devise a proper shielding. Here, two sets of altogether ten moderated $^3$He neutron counters are used for a detailed study of the ambient neutron background in tunnel IV of the Felsenkeller facility, underground below 45 meters of rock in Dresden/Germany. One of the moderators is lined with lead and thus sensitive to neutrons of energies higher than 10 MeV. For each $^3$He counter-moderator assembly, the energy dependent neutron sensitivity was calculated with the FLUKA code. The count rates of the ten detectors were then fitted with the MAXED and GRAVEL packages. As a result, both the neutron energy spectrum from 10$^{-9}$ MeV to 300 MeV and the flux integrated over the same energy range were determined experimentally.
The data show that at a given depth, both the flux and the spectrum vary significantly depending on local conditions. Energy integrated fluxes of $(0.61 \pm 0.05)$, $(1.96 \pm 0.15)$, and $(4.6 \pm 0.4) \times 10^{-4}$ cm$^{-2}$ s$^{-1}$, respectively, are measured for three sites within Felsenkeller tunnel IV which have similar muon flux but different shielding wall configurations.
The integrated neutron flux data and the obtained spectra for the three sites are matched reasonably well by FLUKA Monte Carlo calculations that are based on the known muon flux and composition of the measurement room walls.
△ Less
Submitted 19 June, 2020; v1 submitted 4 June, 2020;
originally announced June 2020.
-
Total Absorption Spectroscopy Study of $^{92}$Rb Decay: A Major Contributor to Reactor Antineutrino Spectrum Shape
Authors:
A. -A. Zakari-Issoufou,
M. Fallot,
A. Porta,
A. Algora,
J. L. Tain,
E. Valencia,
S. Rice,
V. M Bui,
S. Cormon,
M. Estienne,
J. Agramunt,
J. Äystö,
M. Bowry,
J. A. Briz,
R. Caballero-Folch,
D. Cano-Ott,
A. Cucoanes,
V. -V. Elomaa,
T. Eronen,
E. Estévez,
G. F. Farrelly,
A. R. Garcia,
W. Gelletly,
M. B Gomez-Hornillos,
V. Gorlychev
, et al. (22 additional authors not shown)
Abstract:
The antineutrino spectra measured in recent experiments at reactors are inconsistent with calculations based on the conversion of integral beta spectra recorded at the ILL reactor. $^{92}$Rb makes the dominant contribution to the reactor spectrum in the 5-8 MeV range but its decay properties are in question. We have studied $^{92}$Rb decay with total absorption spectroscopy. Previously unobserved…
▽ More
The antineutrino spectra measured in recent experiments at reactors are inconsistent with calculations based on the conversion of integral beta spectra recorded at the ILL reactor. $^{92}$Rb makes the dominant contribution to the reactor spectrum in the 5-8 MeV range but its decay properties are in question. We have studied $^{92}$Rb decay with total absorption spectroscopy. Previously unobserved beta feeding was seen in the 4.5-5.5 region and the GS to GS feeding was found to be 87.5(25)%. The impact on the reactor antineutrino spectra calculated with the summation method is shown and discussed.
△ Less
Submitted 24 September, 2015; v1 submitted 22 April, 2015;
originally announced April 2015.
-
SiPMs coated with TPB : coating protocol and characterization for NEXT
Authors:
V. Álvarez,
J. Agramunt,
M. Ball,
M. Batallé,
J. Bayarri,
F. I. G. Borges,
H. Bolink,
H. Brine,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
J. Ferrando,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira
, et al. (69 additional authors not shown)
Abstract:
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs off…
▽ More
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifter tetraphenyl butadienne (TPB). In this paper we describe the protocol developed for coating the SiPMs with TPB and the measurements performed for characterizing the coatings as well as the performance of the coated sensors in the UV-VUV range.
△ Less
Submitted 10 January, 2012;
originally announced January 2012.