JLab Measurement of the $^4$He Charge Form Factor at Large Momentum Transfers
Authors:
A. Camsonne,
A. T. Katramatou,
M. Olson,
N. Sparveris,
A. Acha,
K. Allada,
B. D. Anderson,
J. Arrington,
A. Baldwin,
J. -P. Chen,
S. Choi,
E. Chudakov,
E. Cisbani,
B. Craver,
P. Decowski,
C. Dutta,
E. Folts,
S. Frullani,
F. Garibaldi,
R. Gilman,
J. Gomez,
B. Hahn,
J. -O. Hansen,
D. Higinbotham,
T. Holmstrom
, et al. (44 additional authors not shown)
Abstract:
The charge form factor of $^$4He has been extracted in the range 29 fm$^{-2}$ $\le Q^2 \le 77$ fm$^{-2}$ from elastic electron scattering, detecting $^4$He nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility of Jefferson Lab. The results are in qualitative agreement with realistic meson-nucleon theoretical calculations. The data have uncovered a second…
▽ More
The charge form factor of $^$4He has been extracted in the range 29 fm$^{-2}$ $\le Q^2 \le 77$ fm$^{-2}$ from elastic electron scattering, detecting $^4$He nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility of Jefferson Lab. The results are in qualitative agreement with realistic meson-nucleon theoretical calculations. The data have uncovered a second diffraction minimum, which was predicted in the $Q^2$ range of this experiment, and rule out conclusively long-standing predictions of dimensional scaling of high-energy amplitudes using quark counting.
△ Less
Submitted 20 September, 2013;
originally announced September 2013.
Performance of the Two Aerogel Cherenkov Detectors of the JLab Hall A Hadron Spectrometer
Authors:
S. Marrone,
B. B. Wojtsekhowski,
A. Acha,
E. Cisbani,
M. Coman,
F. Cusanno,
C. W. de Jager,
R. De Leo,
H. Gao,
F. Garibaldi,
D. W. Higinbotham,
M. Iodice,
J. J. LeRose,
D. Macchia,
P. Markowitz,
E. Nappia,
F. Palmisano,
G. M. Urciuoli,
I. van der Werf,
H. Xiang,
L. Y. Zhu
Abstract:
We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an appropriate choice of PMT type and reflector, along with some design considerations. After four years of operation, the number of detected photoelectrons was found…
▽ More
We report on the design and commissioning of two silica aerogel Cherenkov detectors with different refractive indices. In particular, extraordinary performance in terms of the number of detected photoelectrons was achieved through an appropriate choice of PMT type and reflector, along with some design considerations. After four years of operation, the number of detected photoelectrons was found to be noticeably reduced in both detectors as a result of contamination, yellowing, of the aerogel material. Along with the details of the set-up, we illustrate the characteristics of the detectors during different time periods and the probable causes of the contamination. In particular we show that the replacement of the contaminated aerogel and parts of the reflecting material has almost restored the initial performance of the detectors.
△ Less
Submitted 25 October, 2008;
originally announced October 2008.