-
Precision measurements of the magnetic parameters of LISA Pathfinder test masses
Authors:
M Armano,
H Audley,
J Baird,
P Binetruy,
M Born,
D Bortoluzzi,
E Castelli,
A Cavalleri,
A Cesarini,
A M Cruise,
K Danzmann,
M De Deus Silva,
I Diepholz,
G Dixon,
R Dolesi,
L Ferraioli,
V Ferroni,
E D Fitzsimons,
M Freschi,
L Gesa,
D Giardini,
F Gibert,
R Giusteri,
C Grimani,
J Grzymisch
, et al. (54 additional authors not shown)
Abstract:
A precise characterization of the magnetic properties of LISA Pathfinder free falling test-masses is of special interest for future gravitational wave observatory in space. Magnetic forces have an important impact on the instrument sensitivity in the low frequency regime below the millihertz. In this paper we report on the magnetic injection experiments performed throughout LISA Pathfinder operati…
▽ More
A precise characterization of the magnetic properties of LISA Pathfinder free falling test-masses is of special interest for future gravitational wave observatory in space. Magnetic forces have an important impact on the instrument sensitivity in the low frequency regime below the millihertz. In this paper we report on the magnetic injection experiments performed throughout LISA Pathfinder operations. We show how these experiments allowed a high precision estimate of the instrument magnetic parameters. The remanent magnetic moment was found to have a modulus of $(0.245\pm0.081)\,\rm{nAm}^2$, the x-component of the background magnetic field within the test masses position was measured to be $(414 \pm 74)$ nT and its gradient had a value of $(-7.4\pm 2.1)\,μ$T/m. Finally, we also measured the test mass magnetic susceptibility to be $(-3.35\pm0.15)\times$10$^{-5}$ in the low frequency regime. All results are in agreement with on-ground estimates.
△ Less
Submitted 5 November, 2024; v1 submitted 5 July, 2024;
originally announced July 2024.
-
Magnetic-induced force noise in LISA Pathfinder free-falling test masses
Authors:
M Armano,
H Audley,
J Baird,
P Binetruy,
M Born,
D Bortoluzzi,
E Castelli,
A Cavalleri,
A Cesarini,
A M Cruise,
K Danzmann,
M De Deus Silva,
I Diepholz,
G Dixon,
R Dolesi,
L Ferraioli,
V Ferroni,
E D Fitzsimons,
M Freschi,
L Gesa,
D Giardini,
F Gibert,
R Giusteri,
C Grimani,
J Grzymisch
, et al. (54 additional authors not shown)
Abstract:
LISA Pathfinder was a mission designed to test key technologies required for gravitational wave detection in space. Magnetically driven forces play a key role in the instrument sensitivity in the low-frequency regime, which corresponds to the measurement band of interest for future space-borne gravitational wave observatories. Magnetic-induced forces couple to the test mass motion, introducing a c…
▽ More
LISA Pathfinder was a mission designed to test key technologies required for gravitational wave detection in space. Magnetically driven forces play a key role in the instrument sensitivity in the low-frequency regime, which corresponds to the measurement band of interest for future space-borne gravitational wave observatories. Magnetic-induced forces couple to the test mass motion, introducing a contribution to the relative acceleration noise between the free falling test masses. In this Letter we present the first complete estimate of this term of the instrument performance model. Our results set the magnetic-induced acceleration noise during the February 2017 noise run of $\rm 0.25_{-0.08}^{+0.15}\,fm\,s^{-2}/\sqrt{Hz}$ at 1 mHz and $\rm 1.01_{-0.24}^{+0.73}\, fm\,s^{-2}/\sqrt{Hz}$ at 0.1 mHz. We also discuss how the non-stationarities of the interplanetary magnetic field can affect these values during extreme space weather conditions.
△ Less
Submitted 5 November, 2024; v1 submitted 5 July, 2024;
originally announced July 2024.
-
An instrumented baffle for the Advanced Virgo Input Mode Cleaner End Mirror
Authors:
M. Andres-Carcasona,
O. Ballester,
O. Blanch,
J. Campos,
G. Caneva,
L. Cardiel,
M. Cavalli-Sforza,
P. Chiggiato,
A. Chiummo,
J. A. Ferreira,
J. M. Illa,
C. Karathanasis,
M. Kolstein,
M. Martinez,
A. Macquet,
A. Menendez-Vazquez,
Ll. M. Mir,
J. Mundet,
A. Pasqualetti,
O. Piccinni,
C. Pio,
A. Romero-Rodriguez,
D. Serrano,
V. Dattilo
Abstract:
A novel instrumented baffle surrounding the suspended end mirror in the input mode cleaner cavity of the Virgo interferometer was installed in spring 2021. Since then, the device has been regularly operated in the experiment and the obtained results indicate a good agreement with simulations of the stray light inside the optical cavity. The baffle will operate in the upcoming O4 observation run, s…
▽ More
A novel instrumented baffle surrounding the suspended end mirror in the input mode cleaner cavity of the Virgo interferometer was installed in spring 2021. Since then, the device has been regularly operated in the experiment and the obtained results indicate a good agreement with simulations of the stray light inside the optical cavity. The baffle will operate in the upcoming O4 observation run, serving as a demonstrator of the technology designed to instrument the baffles in front of the main mirrors in time for O5. In this paper we present a detailed description of the baffle design, including mechanics, front-end electronics, data acquisition, as well as optical and vacuum tests, calibration and installation procedures, and performance results.
△ Less
Submitted 16 June, 2023; v1 submitted 27 October, 2022;
originally announced October 2022.
-
Measurement of the Stray Light in the Advanced Virgo Input Mode Cleaner Cavity using an instrumented baffle
Authors:
O. Ballester,
O. Blanch,
L. Cardiel,
M. Cavalli-Sforza,
A. Chiummo,
C. Garcia,
J. M. Illa,
C. Karathanasis,
M. Kolstein,
M. Martinez,
A. Menendez-Vazquez,
Ll. M. Mir,
J. Mundet,
A. Romero-Rodriguez,
D. Serrano,
H. Yamamoto
Abstract:
A new instrumented baffle was installed in Spring 2021 at Virgo surrounding the suspended mirror in the input mode cleaner triangular cavity. It serves as a demonstrator of the technology designed to instrument the baffles in the main arms in the near future. We present, for the first time, results on the measured scattered light distribution inside the cavity as determined by the new device using…
▽ More
A new instrumented baffle was installed in Spring 2021 at Virgo surrounding the suspended mirror in the input mode cleaner triangular cavity. It serves as a demonstrator of the technology designed to instrument the baffles in the main arms in the near future. We present, for the first time, results on the measured scattered light distribution inside the cavity as determined by the new device using data collected between May and July 2021, with Virgo in commissioning phase and operating with an input laser power in the cavity of 28.5~W. The sensitivity of the baffle is discussed and the data is compared to scattered light simulations.
△ Less
Submitted 17 June, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.