-
Synthetic multi-inversion time magnetic resonance images for visualization of subcortical structures
Authors:
Savannah P. Hays,
Lianrui Zuo,
Anqi Feng,
Yihao Liu,
Blake E. Dewey,
Jiachen Zhuo,
Ellen M. Mowry,
Scott D. Newsome Jerry L. Prince,
Aaron Carass
Abstract:
Purpose: Visualization of subcortical gray matter is essential in neuroscience and clinical practice, particularly for disease understanding and surgical planning.While multi-inversion time (multi-TI) T$_1$-weighted (T$_1$-w) magnetic resonance (MR) imaging improves visualization, it is rarely acquired in clinical settings. Approach: We present SyMTIC (Synthetic Multi-TI Contrasts), a deep learnin…
▽ More
Purpose: Visualization of subcortical gray matter is essential in neuroscience and clinical practice, particularly for disease understanding and surgical planning.While multi-inversion time (multi-TI) T$_1$-weighted (T$_1$-w) magnetic resonance (MR) imaging improves visualization, it is rarely acquired in clinical settings. Approach: We present SyMTIC (Synthetic Multi-TI Contrasts), a deep learning method that generates synthetic multi-TI images using routinely acquired T$_1$-w, T$_2$-weighted (T$_2$-w), and FLAIR images. Our approach combines image translation via deep neural networks with imaging physics to estimate longitudinal relaxation time (T$_1$) and proton density (PD) maps. These maps are then used to compute multi-TI images with arbitrary inversion times. Results: SyMTIC was trained using paired MPRAGE and FGATIR images along with T$_2$-w and FLAIR images. It accurately synthesized multi-TI images from standard clinical inputs, achieving image quality comparable to that from explicitly acquired multi-TI data.The synthetic images, especially for TI values between 400-800 ms, enhanced visualization of subcortical structures and improved segmentation of thalamic nuclei. Conclusion: SyMTIC enables robust generation of high-quality multi-TI images from routine MR contrasts. It generalizes well to varied clinical datasets, including those with missing FLAIR images or unknown parameters, offering a practical solution for improving brain MR image visualization and analysis.
△ Less
Submitted 4 June, 2025;
originally announced June 2025.
-
Beyond the LUMIR challenge: The pathway to foundational registration models
Authors:
Junyu Chen,
Shuwen Wei,
Joel Honkamaa,
Pekka Marttinen,
Hang Zhang,
Min Liu,
Yichao Zhou,
Zuopeng Tan,
Zhuoyuan Wang,
Yi Wang,
Hongchao Zhou,
Shunbo Hu,
Yi Zhang,
Qian Tao,
Lukas Förner,
Thomas Wendler,
Bailiang Jian,
Benedikt Wiestler,
Tim Hable,
Jin Kim,
Dan Ruan,
Frederic Madesta,
Thilo Sentker,
Wiebke Heyer,
Lianrui Zuo
, et al. (11 additional authors not shown)
Abstract:
Medical image challenges have played a transformative role in advancing the field, catalyzing algorithmic innovation and establishing new performance standards across diverse clinical applications. Image registration, a foundational task in neuroimaging pipelines, has similarly benefited from the Learn2Reg initiative. Building on this foundation, we introduce the Large-scale Unsupervised Brain MRI…
▽ More
Medical image challenges have played a transformative role in advancing the field, catalyzing algorithmic innovation and establishing new performance standards across diverse clinical applications. Image registration, a foundational task in neuroimaging pipelines, has similarly benefited from the Learn2Reg initiative. Building on this foundation, we introduce the Large-scale Unsupervised Brain MRI Image Registration (LUMIR) challenge, a next-generation benchmark designed to assess and advance unsupervised brain MRI registration. Distinct from prior challenges that leveraged anatomical label maps for supervision, LUMIR removes this dependency by providing over 4,000 preprocessed T1-weighted brain MRIs for training without any label maps, encouraging biologically plausible deformation modeling through self-supervision. In addition to evaluating performance on 590 held-out test subjects, LUMIR introduces a rigorous suite of zero-shot generalization tasks, spanning out-of-domain imaging modalities (e.g., FLAIR, T2-weighted, T2*-weighted), disease populations (e.g., Alzheimer's disease), acquisition protocols (e.g., 9.4T MRI), and species (e.g., macaque brains). A total of 1,158 subjects and over 4,000 image pairs were included for evaluation. Performance was assessed using both segmentation-based metrics (Dice coefficient, 95th percentile Hausdorff distance) and landmark-based registration accuracy (target registration error). Across both in-domain and zero-shot tasks, deep learning-based methods consistently achieved state-of-the-art accuracy while producing anatomically plausible deformation fields. The top-performing deep learning-based models demonstrated diffeomorphic properties and inverse consistency, outperforming several leading optimization-based methods, and showing strong robustness to most domain shifts, the exception being a drop in performance on out-of-domain contrasts.
△ Less
Submitted 29 May, 2025;
originally announced May 2025.
-
Multipath cycleGAN for harmonization of paired and unpaired low-dose lung computed tomography reconstruction kernels
Authors:
Aravind R. Krishnan,
Thomas Z. Li,
Lucas W. Remedios,
Michael E. Kim,
Chenyu Gao,
Gaurav Rudravaram,
Elyssa M. McMaster,
Adam M. Saunders,
Shunxing Bao,
Kaiwen Xu,
Lianrui Zuo,
Kim L. Sandler,
Fabien Maldonado,
Yuankai Huo,
Bennett A. Landman
Abstract:
Reconstruction kernels in computed tomography (CT) affect spatial resolution and noise characteristics, introducing systematic variability in quantitative imaging measurements such as emphysema quantification. Choosing an appropriate kernel is therefore essential for consistent quantitative analysis. We propose a multipath cycleGAN model for CT kernel harmonization, trained on a mixture of paired…
▽ More
Reconstruction kernels in computed tomography (CT) affect spatial resolution and noise characteristics, introducing systematic variability in quantitative imaging measurements such as emphysema quantification. Choosing an appropriate kernel is therefore essential for consistent quantitative analysis. We propose a multipath cycleGAN model for CT kernel harmonization, trained on a mixture of paired and unpaired data from a low-dose lung cancer screening cohort. The model features domain-specific encoders and decoders with a shared latent space and uses discriminators tailored for each domain.We train the model on 42 kernel combinations using 100 scans each from seven representative kernels in the National Lung Screening Trial (NLST) dataset. To evaluate performance, 240 scans from each kernel are harmonized to a reference soft kernel, and emphysema is quantified before and after harmonization. A general linear model assesses the impact of age, sex, smoking status, and kernel on emphysema. We also evaluate harmonization from soft kernels to a reference hard kernel. To assess anatomical consistency, we compare segmentations of lung vessels, muscle, and subcutaneous adipose tissue generated by TotalSegmentator between harmonized and original images. Our model is benchmarked against traditional and switchable cycleGANs. For paired kernels, our approach reduces bias in emphysema scores, as seen in Bland-Altman plots (p<0.05). For unpaired kernels, harmonization eliminates confounding differences in emphysema (p>0.05). High Dice scores confirm preservation of muscle and fat anatomy, while lung vessel overlap remains reasonable. Overall, our shared latent space multipath cycleGAN enables robust harmonization across paired and unpaired CT kernels, improving emphysema quantification and preserving anatomical fidelity.
△ Less
Submitted 28 May, 2025;
originally announced May 2025.
-
Investigating the impact of kernel harmonization and deformable registration on inspiratory and expiratory chest CT images for people with COPD
Authors:
Aravind R. Krishnan,
Yihao Liu,
Kaiwen Xu,
Michael E. Kim,
Lucas W. Remedios,
Gaurav Rudravaram,
Adam M. Saunders,
Bradley W. Richmond,
Kim L. Sandler,
Fabien Maldonado,
Bennett A. Landman,
Lianrui Zuo
Abstract:
Paired inspiratory-expiratory CT scans enable the quantification of gas trapping due to small airway disease and emphysema by analyzing lung tissue motion in COPD patients. Deformable image registration of these scans assesses regional lung volumetric changes. However, variations in reconstruction kernels between paired scans introduce errors in quantitative analysis. This work proposes a two-stag…
▽ More
Paired inspiratory-expiratory CT scans enable the quantification of gas trapping due to small airway disease and emphysema by analyzing lung tissue motion in COPD patients. Deformable image registration of these scans assesses regional lung volumetric changes. However, variations in reconstruction kernels between paired scans introduce errors in quantitative analysis. This work proposes a two-stage pipeline to harmonize reconstruction kernels and perform deformable image registration using data acquired from the COPDGene study. We use a cycle generative adversarial network (GAN) to harmonize inspiratory scans reconstructed with a hard kernel (BONE) to match expiratory scans reconstructed with a soft kernel (STANDARD). We then deformably register the expiratory scans to inspiratory scans. We validate harmonization by measuring emphysema using a publicly available segmentation algorithm before and after harmonization. Results show harmonization significantly reduces emphysema measurement inconsistencies, decreasing median emphysema scores from 10.479% to 3.039%, with a reference median score of 1.305% from the STANDARD kernel as the target. Registration accuracy is evaluated via Dice overlap between emphysema regions on inspiratory, expiratory, and deformed images. The Dice coefficient between inspiratory emphysema masks and deformably registered emphysema masks increases significantly across registration stages (p<0.001). Additionally, we demonstrate that deformable registration is robust to kernel variations.
△ Less
Submitted 7 February, 2025;
originally announced February 2025.
-
Pitfalls of defacing whole-head MRI: re-identification risk with diffusion models and compromised research potential
Authors:
Chenyu Gao,
Kaiwen Xu,
Michael E. Kim,
Lianrui Zuo,
Zhiyuan Li,
Derek B. Archer,
Timothy J. Hohman,
Ann Zenobia Moore,
Luigi Ferrucci,
Lori L. Beason-Held,
Susan M. Resnick,
Christos Davatzikos,
Jerry L. Prince,
Bennett A. Landman
Abstract:
Defacing is often applied to head magnetic resonance image (MRI) datasets prior to public release to address privacy concerns. The alteration of facial and nearby voxels has provoked discussions about the true capability of these techniques to ensure privacy as well as their impact on downstream tasks. With advancements in deep generative models, the extent to which defacing can protect privacy is…
▽ More
Defacing is often applied to head magnetic resonance image (MRI) datasets prior to public release to address privacy concerns. The alteration of facial and nearby voxels has provoked discussions about the true capability of these techniques to ensure privacy as well as their impact on downstream tasks. With advancements in deep generative models, the extent to which defacing can protect privacy is uncertain. Additionally, while the altered voxels are known to contain valuable anatomical information, their potential to support research beyond the anatomical regions directly affected by defacing remains uncertain. To evaluate these considerations, we develop a refacing pipeline that recovers faces in defaced head MRIs using cascaded diffusion probabilistic models (DPMs). The DPMs are trained on images from 180 subjects and tested on images from 484 unseen subjects, 469 of whom are from a different dataset. To assess whether the altered voxels in defacing contain universally useful information, we also predict computed tomography (CT)-derived skeletal muscle radiodensity from facial voxels in both defaced and original MRIs. The results show that DPMs can generate high-fidelity faces that resemble the original faces from defaced images, with surface distances to the original faces significantly smaller than those of a population average face (p < 0.05). This performance also generalizes well to previously unseen datasets. For skeletal muscle radiodensity predictions, using defaced images results in significantly weaker Spearman's rank correlation coefficients compared to using original images (p < 10-4). For shin muscle, the correlation is statistically significant (p < 0.05) when using original images but not statistically significant (p > 0.05) when any defacing method is applied, suggesting that defacing might not only fail to protect privacy but also eliminate valuable information.
△ Less
Submitted 30 January, 2025;
originally announced January 2025.
-
Robust Body Composition Analysis by Generating 3D CT Volumes from Limited 2D Slices
Authors:
Lianrui Zuo,
Xin Yu,
Dingjie Su,
Kaiwen Xu,
Aravind R. Krishnan,
Yihao Liu,
Shunxing Bao,
Fabien Maldonado,
Luigi Ferrucci,
Bennett A. Landman
Abstract:
Body composition analysis provides valuable insights into aging, disease progression, and overall health conditions. Due to concerns of radiation exposure, two-dimensional (2D) single-slice computed tomography (CT) imaging has been used repeatedly for body composition analysis. However, this approach introduces significant spatial variability that can impact the accuracy and robustness of the anal…
▽ More
Body composition analysis provides valuable insights into aging, disease progression, and overall health conditions. Due to concerns of radiation exposure, two-dimensional (2D) single-slice computed tomography (CT) imaging has been used repeatedly for body composition analysis. However, this approach introduces significant spatial variability that can impact the accuracy and robustness of the analysis. To mitigate this issue and facilitate body composition analysis, this paper presents a novel method to generate 3D CT volumes from limited number of 2D slices using a latent diffusion model (LDM). Our approach first maps 2D slices into a latent representation space using a variational autoencoder. An LDM is then trained to capture the 3D context of a stack of these latent representations. To accurately interpolate intermediateslices and construct a full 3D volume, we utilize body part regression to determine the spatial location and distance between the acquired slices. Experiments on both in-house and public 3D abdominal CT datasets demonstrate that the proposed method significantly enhances body composition analysis compared to traditional 2D-based analysis, with a reduced error rate from 23.3% to 15.2%.
△ Less
Submitted 22 January, 2025;
originally announced January 2025.
-
Beyond the Lungs: Extending the Field of View in Chest CT with Latent Diffusion Models
Authors:
Lianrui Zuo,
Kaiwen Xu,
Dingjie Su,
Xin Yu,
Aravind R. Krishnan,
Yihao Liu,
Shunxing Bao,
Thomas Li,
Kim L. Sandler,
Fabien Maldonado,
Bennett A. Landman
Abstract:
The interconnection between the human lungs and other organs, such as the liver and kidneys, is crucial for understanding the underlying risks and effects of lung diseases and improving patient care. However, most research chest CT imaging is focused solely on the lungs due to considerations of cost and radiation dose. This restricted field of view (FOV) in the acquired images poses challenges to…
▽ More
The interconnection between the human lungs and other organs, such as the liver and kidneys, is crucial for understanding the underlying risks and effects of lung diseases and improving patient care. However, most research chest CT imaging is focused solely on the lungs due to considerations of cost and radiation dose. This restricted field of view (FOV) in the acquired images poses challenges to comprehensive analysis and hinders the ability to gain insights into the impact of lung diseases on other organs. To address this, we propose SCOPE (Spatial Coverage Optimization with Prior Encoding), a novel approach to capture the inter-organ relationships from CT images and extend the FOV of chest CT images. Our approach first trains a variational autoencoder (VAE) to encode 2D axial CT slices individually, then stacks the latent representations of the VAE to form a 3D context for training a latent diffusion model. Once trained, our approach extends the FOV of CT images in the z-direction by generating new axial slices in a zero-shot manner. We evaluated our approach on the National Lung Screening Trial (NLST) dataset, and results suggest that it effectively extends the FOV to include the liver and kidneys, which are not completely covered in the original NLST data acquisition. Quantitative results on a held-out whole-body dataset demonstrate that the generated slices exhibit high fidelity with acquired data, achieving an SSIM of 0.81.
△ Less
Submitted 22 January, 2025;
originally announced January 2025.
-
Generalized Scattering Matrix of Antenna: Moment Solution, Compression Storage and Application
Authors:
Chenbo Shi,
Jin Pan,
Xin Gu,
Shichen Liang,
Le Zuo
Abstract:
This paper presents a computation method of generalized scattering matrix (GSM) based on integral equations and the method of moments (MoM), specifically designed for antennas excited through waveguide ports. By leveraging two distinct formulations -- magnetic-type and electric-type integral equations -- we establish concise algebraic relations linking the GSM directly to the impedance matrices ob…
▽ More
This paper presents a computation method of generalized scattering matrix (GSM) based on integral equations and the method of moments (MoM), specifically designed for antennas excited through waveguide ports. By leveraging two distinct formulations -- magnetic-type and electric-type integral equations -- we establish concise algebraic relations linking the GSM directly to the impedance matrices obtained from MoM. To address practical challenges in storing GSM data across wide frequency bands and multiple antenna scenarios, we propose a efficient compression scheme. This approach alleviates memory demands by selectively storing the dominant eigencomponents that govern scattering behavior. Numerical validation examples confirm the accuracy of our method by comparisons with full-wave simulation results. Furthermore, we introduce an efficient iterative procedure to predict antenna array performance, highlighting remarkable improvements in computational speed compared to conventional numerical methods. These results collectively demonstrate the GSM framework's strong potential for antenna-array design processes.
△ Less
Submitted 23 April, 2025; v1 submitted 29 October, 2024;
originally announced November 2024.
-
Bi-Directional MS Lesion Filling and Synthesis Using Denoising Diffusion Implicit Model-based Lesion Repainting
Authors:
Jinwei Zhang,
Lianrui Zuo,
Yihao Liu,
Samuel Remedios,
Bennett A. Landman,
Jerry L. Prince,
Aaron Carass
Abstract:
Automatic magnetic resonance (MR) image processing pipelines are widely used to study people with multiple sclerosis (PwMS), encompassing tasks such as lesion segmentation and brain parcellation. However, the presence of lesion often complicates these analysis, particularly in brain parcellation. Lesion filling is commonly used to mitigate this issue, but existing lesion filling algorithms often f…
▽ More
Automatic magnetic resonance (MR) image processing pipelines are widely used to study people with multiple sclerosis (PwMS), encompassing tasks such as lesion segmentation and brain parcellation. However, the presence of lesion often complicates these analysis, particularly in brain parcellation. Lesion filling is commonly used to mitigate this issue, but existing lesion filling algorithms often fall short in accurately reconstructing realistic lesion-free images, which are vital for consistent downstream analysis. Additionally, the performance of lesion segmentation algorithms is often limited by insufficient data with lesion delineation as training labels. In this paper, we propose a novel approach leveraging Denoising Diffusion Implicit Models (DDIMs) for both MS lesion filling and synthesis based on image inpainting. Our modified DDIM architecture, once trained, enables both MS lesion filing and synthesis. Specifically, it can generate lesion-free T1-weighted or FLAIR images from those containing lesions; Or it can add lesions to T1-weighted or FLAIR images of healthy subjects. The former is essential for downstream analyses that require lesion-free images, while the latter is valuable for augmenting training datasets for lesion segmentation tasks. We validate our approach through initial experiments in this paper and demonstrate promising results in both lesion filling and synthesis, paving the way for future work.
△ Less
Submitted 7 October, 2024;
originally announced October 2024.
-
Beyond MR Image Harmonization: Resolution Matters Too
Authors:
Savannah P. Hays,
Samuel W. Remedios,
Lianrui Zuo,
Ellen M. Mowry,
Scott D. Newsome,
Peter A. Calabresi,
Aaron Carass,
Blake E. Dewey,
Jerry L. Prince
Abstract:
Magnetic resonance (MR) imaging is commonly used in the clinical setting to non-invasively monitor the body. There exists a large variability in MR imaging due to differences in scanner hardware, software, and protocol design. Ideally, a processing algorithm should perform robustly to this variability, but that is not always the case in reality. This introduces a need for image harmonization to ov…
▽ More
Magnetic resonance (MR) imaging is commonly used in the clinical setting to non-invasively monitor the body. There exists a large variability in MR imaging due to differences in scanner hardware, software, and protocol design. Ideally, a processing algorithm should perform robustly to this variability, but that is not always the case in reality. This introduces a need for image harmonization to overcome issues of domain shift when performing downstream analysis such as segmentation. Most image harmonization models focus on acquisition parameters such as inversion time or repetition time, but they ignore an important aspect in MR imaging -- resolution. In this paper, we evaluate the impact of image resolution on harmonization using a pretrained harmonization algorithm. We simulate 2D acquisitions of various slice thicknesses and gaps from 3D acquired, 1mm3 isotropic MR images and demonstrate how the performance of a state-of-the-art image harmonization algorithm varies as resolution changes. We discuss the most ideal scenarios for image resolution including acquisition orientation when 3D imaging is not available, which is common for many clinical scanners. Our results show that harmonization on low-resolution images does not account for acquisition resolution and orientation variations. Super-resolution can be used to alleviate resolution variations but it is not always used. Our methodology can generalize to help evaluate the impact of image acquisition resolution for multiple tasks. Determining the limits of a pretrained algorithm is important when considering preprocessing steps and trust in the results.
△ Less
Submitted 30 August, 2024; v1 submitted 29 August, 2024;
originally announced August 2024.
-
Revisiting registration-based synthesis: A focus on unsupervised MR image synthesis
Authors:
Savannah P. Hays,
Lianrui Zuo,
Yihao Liu,
Anqi Feng,
Jiachen Zhuo,
Jerry L. Prince,
Aaron Carass
Abstract:
Deep learning (DL) has led to significant improvements in medical image synthesis, enabling advanced image-to-image translation to generate synthetic images. However, DL methods face challenges such as domain shift and high demands for training data, limiting their generalizability and applicability. Historically, image synthesis was also carried out using deformable image registration (DIR), a me…
▽ More
Deep learning (DL) has led to significant improvements in medical image synthesis, enabling advanced image-to-image translation to generate synthetic images. However, DL methods face challenges such as domain shift and high demands for training data, limiting their generalizability and applicability. Historically, image synthesis was also carried out using deformable image registration (DIR), a method that warps moving images of a desired modality to match the anatomy of a fixed image. However, concerns about its speed and accuracy led to its decline in popularity. With the recent advances of DL-based DIR, we now revisit and reinvigorate this line of research. In this paper, we propose a fast and accurate synthesis method based on DIR. We use the task of synthesizing a rare magnetic resonance (MR) sequence, white matter nulled (WMn) T1-weighted (T1-w) images, to demonstrate the potential of our approach. During training, our method learns a DIR model based on the widely available MPRAGE sequence, which is a cerebrospinal fluid nulled (CSFn) T1-w inversion recovery gradient echo pulse sequence. During testing, the trained DIR model is first applied to estimate the deformation between moving and fixed CSFn images. Subsequently, this estimated deformation is applied to align the paired WMn counterpart of the moving CSFn image, yielding a synthetic WMn image for the fixed CSFn image. Our experiments demonstrate promising results for unsupervised image synthesis using DIR. These findings highlight the potential of our technique in contexts where supervised synthesis methods are constrained by limited training data.
△ Less
Submitted 19 February, 2024;
originally announced February 2024.
-
Shrinking Your TimeStep: Towards Low-Latency Neuromorphic Object Recognition with Spiking Neural Network
Authors:
Yongqi Ding,
Lin Zuo,
Mengmeng Jing,
Pei He,
Yongjun Xiao
Abstract:
Neuromorphic object recognition with spiking neural networks (SNNs) is the cornerstone of low-power neuromorphic computing. However, existing SNNs suffer from significant latency, utilizing 10 to 40 timesteps or more, to recognize neuromorphic objects. At low latencies, the performance of existing SNNs is drastically degraded. In this work, we propose the Shrinking SNN (SSNN) to achieve low-latenc…
▽ More
Neuromorphic object recognition with spiking neural networks (SNNs) is the cornerstone of low-power neuromorphic computing. However, existing SNNs suffer from significant latency, utilizing 10 to 40 timesteps or more, to recognize neuromorphic objects. At low latencies, the performance of existing SNNs is drastically degraded. In this work, we propose the Shrinking SNN (SSNN) to achieve low-latency neuromorphic object recognition without reducing performance. Concretely, we alleviate the temporal redundancy in SNNs by dividing SNNs into multiple stages with progressively shrinking timesteps, which significantly reduces the inference latency. During timestep shrinkage, the temporal transformer smoothly transforms the temporal scale and preserves the information maximally. Moreover, we add multiple early classifiers to the SNN during training to mitigate the mismatch between the surrogate gradient and the true gradient, as well as the gradient vanishing/exploding, thus eliminating the performance degradation at low latency. Extensive experiments on neuromorphic datasets, CIFAR10-DVS, N-Caltech101, and DVS-Gesture have revealed that SSNN is able to improve the baseline accuracy by 6.55% ~ 21.41%. With only 5 average timesteps and without any data augmentation, SSNN is able to achieve an accuracy of 73.63% on CIFAR10-DVS. This work presents a heterogeneous temporal scale SNN and provides valuable insights into the development of high-performance, low-latency SNNs.
△ Less
Submitted 1 January, 2024;
originally announced January 2024.
-
Advancing VAD Systems Based on Multi-Task Learning with Improved Model Structures
Authors:
Lingyun Zuo,
Keyu An,
Shiliang Zhang,
Zhijie Yan
Abstract:
In a speech recognition system, voice activity detection (VAD) is a crucial frontend module. Addressing the issues of poor noise robustness in traditional binary VAD systems based on DFSMN, the paper further proposes semantic VAD based on multi-task learning with improved models for real-time and offline systems, to meet specific application requirements. Evaluations on internal datasets show that…
▽ More
In a speech recognition system, voice activity detection (VAD) is a crucial frontend module. Addressing the issues of poor noise robustness in traditional binary VAD systems based on DFSMN, the paper further proposes semantic VAD based on multi-task learning with improved models for real-time and offline systems, to meet specific application requirements. Evaluations on internal datasets show that, compared to the real-time VAD system based on DFSMN, the real-time semantic VAD system based on RWKV achieves relative decreases in CER of 7.0\%, DCF of 26.1\% and relative improvement in NRR of 19.2\%. Similarly, when compared to the offline VAD system based on DFSMN, the offline VAD system based on SAN-M demonstrates relative decreases in CER of 4.4\%, DCF of 18.6\% and relative improvement in NRR of 3.5\%.
△ Less
Submitted 19 December, 2023;
originally announced December 2023.
-
Towards an accurate and generalizable multiple sclerosis lesion segmentation model using self-ensembled lesion fusion
Authors:
Jinwei Zhang,
Lianrui Zuo,
Blake E. Dewey,
Samuel W. Remedios,
Dzung L. Pham,
Aaron Carass,
Jerry L. Prince
Abstract:
Automatic multiple sclerosis (MS) lesion segmentation using multi-contrast magnetic resonance (MR) images provides improved efficiency and reproducibility compared to manual delineation. Current state-of-the-art automatic MS lesion segmentation methods utilize modified U-Net-like architectures. However, in the literature, dedicated architecture modifications were always required to maximize their…
▽ More
Automatic multiple sclerosis (MS) lesion segmentation using multi-contrast magnetic resonance (MR) images provides improved efficiency and reproducibility compared to manual delineation. Current state-of-the-art automatic MS lesion segmentation methods utilize modified U-Net-like architectures. However, in the literature, dedicated architecture modifications were always required to maximize their performance. In addition, the best-performing methods have not proven to be generalizable to diverse test datasets with contrast variations and image artifacts. In this work, we developed an accurate and generalizable MS lesion segmentation model using the well-known U-Net architecture without further modification. A novel test-time self-ensembled lesion fusion strategy is proposed that not only achieved the best performance using the ISBI 2015 MS segmentation challenge data but also demonstrated robustness across various self-ensemble parameter choices. Moreover, equipped with instance normalization rather than batch normalization widely used in literature, the model trained on the ISBI challenge data generalized well on clinical test datasets from different scanners.
△ Less
Submitted 3 December, 2023;
originally announced December 2023.
-
Harmonization-enriched domain adaptation with light fine-tuning for multiple sclerosis lesion segmentation
Authors:
Jinwei Zhang,
Lianrui Zuo,
Blake E. Dewey,
Samuel W. Remedios,
Savannah P. Hays,
Dzung L. Pham,
Jerry L. Prince,
Aaron Carass
Abstract:
Deep learning algorithms utilizing magnetic resonance (MR) images have demonstrated cutting-edge proficiency in autonomously segmenting multiple sclerosis (MS) lesions. Despite their achievements, these algorithms may struggle to extend their performance across various sites or scanners, leading to domain generalization errors. While few-shot or one-shot domain adaptation emerges as a potential so…
▽ More
Deep learning algorithms utilizing magnetic resonance (MR) images have demonstrated cutting-edge proficiency in autonomously segmenting multiple sclerosis (MS) lesions. Despite their achievements, these algorithms may struggle to extend their performance across various sites or scanners, leading to domain generalization errors. While few-shot or one-shot domain adaptation emerges as a potential solution to mitigate generalization errors, its efficacy might be hindered by the scarcity of labeled data in the target domain. This paper seeks to tackle this challenge by integrating one-shot adaptation data with harmonized training data that incorporates labels. Our approach involves synthesizing new training data with a contrast akin to that of the test domain, a process we refer to as "contrast harmonization" in MRI. Our experiments illustrate that the amalgamation of one-shot adaptation data with harmonized training data surpasses the performance of utilizing either data source in isolation. Notably, domain adaptation using exclusively harmonized training data achieved comparable or even superior performance compared to one-shot adaptation. Moreover, all adaptations required only minimal fine-tuning, ranging from 2 to 5 epochs for convergence.
△ Less
Submitted 31 October, 2023;
originally announced October 2023.
-
Semantic VAD: Low-Latency Voice Activity Detection for Speech Interaction
Authors:
Mohan Shi,
Yuchun Shu,
Lingyun Zuo,
Qian Chen,
Shiliang Zhang,
Jie Zhang,
Li-Rong Dai
Abstract:
For speech interaction, voice activity detection (VAD) is often used as a front-end. However, traditional VAD algorithms usually need to wait for a continuous tail silence to reach a preset maximum duration before segmentation, resulting in a large latency that affects user experience. In this paper, we propose a novel semantic VAD for low-latency segmentation. Different from existing methods, a f…
▽ More
For speech interaction, voice activity detection (VAD) is often used as a front-end. However, traditional VAD algorithms usually need to wait for a continuous tail silence to reach a preset maximum duration before segmentation, resulting in a large latency that affects user experience. In this paper, we propose a novel semantic VAD for low-latency segmentation. Different from existing methods, a frame-level punctuation prediction task is added to the semantic VAD, and the artificial endpoint is included in the classification category in addition to the often-used speech presence and absence. To enhance the semantic information of the model, we also incorporate an automatic speech recognition (ASR) related semantic loss. Evaluations on an internal dataset show that the proposed method can reduce the average latency by 53.3% without significant deterioration of character error rate in the back-end ASR compared to the traditional VAD approach.
△ Less
Submitted 21 May, 2023;
originally announced May 2023.
-
FunASR: A Fundamental End-to-End Speech Recognition Toolkit
Authors:
Zhifu Gao,
Zerui Li,
Jiaming Wang,
Haoneng Luo,
Xian Shi,
Mengzhe Chen,
Yabin Li,
Lingyun Zuo,
Zhihao Du,
Zhangyu Xiao,
Shiliang Zhang
Abstract:
This paper introduces FunASR, an open-source speech recognition toolkit designed to bridge the gap between academic research and industrial applications. FunASR offers models trained on large-scale industrial corpora and the ability to deploy them in applications. The toolkit's flagship model, Paraformer, is a non-autoregressive end-to-end speech recognition model that has been trained on a manual…
▽ More
This paper introduces FunASR, an open-source speech recognition toolkit designed to bridge the gap between academic research and industrial applications. FunASR offers models trained on large-scale industrial corpora and the ability to deploy them in applications. The toolkit's flagship model, Paraformer, is a non-autoregressive end-to-end speech recognition model that has been trained on a manually annotated Mandarin speech recognition dataset that contains 60,000 hours of speech. To improve the performance of Paraformer, we have added timestamp prediction and hotword customization capabilities to the standard Paraformer backbone. In addition, to facilitate model deployment, we have open-sourced a voice activity detection model based on the Feedforward Sequential Memory Network (FSMN-VAD) and a text post-processing punctuation model based on the controllable time-delay Transformer (CT-Transformer), both of which were trained on industrial corpora. These functional modules provide a solid foundation for building high-precision long audio speech recognition services. Compared to other models trained on open datasets, Paraformer demonstrates superior performance.
△ Less
Submitted 18 May, 2023;
originally announced May 2023.
-
Rapid Brain Meninges Surface Reconstruction with Layer Topology Guarantee
Authors:
Peiyu Duan,
Yuan Xue,
Shuo Han,
Lianrui Zuo,
Aaron Carass,
Caitlyn Bernhard,
Savannah Hays,
Peter A. Calabresi,
Susan M. Resnick,
James S. Duncan,
Jerry L. Prince
Abstract:
The meninges, located between the skull and brain, are composed of three membrane layers: the pia, the arachnoid, and the dura. Reconstruction of these layers can aid in studying volume differences between patients with neurodegenerative diseases and normal aging subjects. In this work, we use convolutional neural networks (CNNs) to reconstruct surfaces representing meningeal layer boundaries from…
▽ More
The meninges, located between the skull and brain, are composed of three membrane layers: the pia, the arachnoid, and the dura. Reconstruction of these layers can aid in studying volume differences between patients with neurodegenerative diseases and normal aging subjects. In this work, we use convolutional neural networks (CNNs) to reconstruct surfaces representing meningeal layer boundaries from magnetic resonance (MR) images. We first use the CNNs to predict the signed distance functions (SDFs) representing these surfaces while preserving their anatomical ordering. The marching cubes algorithm is then used to generate continuous surface representations; both the subarachnoid space (SAS) and the intracranial volume (ICV) are computed from these surfaces. The proposed method is compared to a state-of-the-art deformable model-based reconstruction method, and we show that our method can reconstruct smoother and more accurate surfaces using less computation time. Finally, we conduct experiments with volumetric analysis on both subjects with multiple sclerosis and healthy controls. For healthy and MS subjects, ICVs and SAS volumes are found to be significantly correlated to sex (p<0.01) and age (p<0.03) changes, respectively.
△ Less
Submitted 12 April, 2023;
originally announced April 2023.
-
Optimal operating MR contrast for brain ventricle parcellation
Authors:
Savannah P. Hays,
Lianrui Zuo,
Yuli Wang,
Mark G. Luciano,
Aaron Carass,
Jerry L. Prince
Abstract:
Development of MR harmonization has enabled different contrast MRIs to be synthesized while preserving the underlying anatomy. In this paper, we use image harmonization to explore the impact of different T1-w MR contrasts on a state-of-the-art ventricle parcellation algorithm VParNet. We identify an optimal operating contrast (OOC) for ventricle parcellation; by showing that the performance of a p…
▽ More
Development of MR harmonization has enabled different contrast MRIs to be synthesized while preserving the underlying anatomy. In this paper, we use image harmonization to explore the impact of different T1-w MR contrasts on a state-of-the-art ventricle parcellation algorithm VParNet. We identify an optimal operating contrast (OOC) for ventricle parcellation; by showing that the performance of a pretrained VParNet can be boosted by adjusting contrast to the OOC.
△ Less
Submitted 4 April, 2023;
originally announced April 2023.
-
Automated Ventricle Parcellation and Evan's Ratio Computation in Pre- and Post-Surgical Ventriculomegaly
Authors:
Yuli Wang,
Anqi Feng,
Yuan Xue,
Lianrui Zuo,
Yihao Liu,
Ari M. Blitz,
Mark G. Luciano,
Aaron Carass,
Jerry L. Prince
Abstract:
Normal pressure hydrocephalus~(NPH) is a brain disorder associated with enlarged ventricles and multiple cognitive and motor symptoms. The degree of ventricular enlargement can be measured using magnetic resonance images~(MRIs) and characterized quantitatively using the Evan's ratio (ER). Automatic computation of ER is desired to avoid the extra time and variations associated with manual measureme…
▽ More
Normal pressure hydrocephalus~(NPH) is a brain disorder associated with enlarged ventricles and multiple cognitive and motor symptoms. The degree of ventricular enlargement can be measured using magnetic resonance images~(MRIs) and characterized quantitatively using the Evan's ratio (ER). Automatic computation of ER is desired to avoid the extra time and variations associated with manual measurements on MRI. Because shunt surgery is often used to treat NPH, it is necessary that this process be robust to image artifacts caused by the shunt and related implants. In this paper, we propose a 3D regions-of-interest aware (ROI-aware) network for segmenting the ventricles. The method achieves state-of-the-art performance on both pre-surgery MRIs and post-surgery MRIs with artifacts. Based on our segmentation results, we also describe an automated approach to compute ER from these results. Experimental results on multiple datasets demonstrate the potential of the proposed method to assist clinicians in the diagnosis and management of NPH.
△ Less
Submitted 6 March, 2023; v1 submitted 3 March, 2023;
originally announced March 2023.
-
A latent space for unsupervised MR image quality control via artifact assessment
Authors:
Lianrui Zuo,
Yuan Xue,
Blake E. Dewey,
Yihao Liu,
Jerry L. Prince,
Aaron Carass
Abstract:
Image quality control (IQC) can be used in automated magnetic resonance (MR) image analysis to exclude erroneous results caused by poorly acquired or artifact-laden images. Existing IQC methods for MR imaging generally require human effort to craft meaningful features or label large datasets for supervised training. The involvement of human labor can be burdensome and biased, as labeling MR images…
▽ More
Image quality control (IQC) can be used in automated magnetic resonance (MR) image analysis to exclude erroneous results caused by poorly acquired or artifact-laden images. Existing IQC methods for MR imaging generally require human effort to craft meaningful features or label large datasets for supervised training. The involvement of human labor can be burdensome and biased, as labeling MR images based on their quality is a subjective task. In this paper, we propose an automatic IQC method that evaluates the extent of artifacts in MR images without supervision. In particular, we design an artifact encoding network that learns representations of artifacts based on contrastive learning. We then use a normalizing flow to estimate the density of learned representations for unsupervised classification. Our experiments on large-scale multi-cohort MR datasets show that the proposed method accurately detects images with high levels of artifacts, which can inform downstream analysis tasks about potentially flawed data.
△ Less
Submitted 1 February, 2023;
originally announced February 2023.
-
HACA3: A Unified Approach for Multi-site MR Image Harmonization
Authors:
Lianrui Zuo,
Yihao Liu,
Yuan Xue,
Blake E. Dewey,
Samuel W. Remedios,
Savannah P. Hays,
Murat Bilgel,
Ellen M. Mowry,
Scott D. Newsome,
Peter A. Calabresi,
Susan M. Resnick,
Jerry L. Prince,
Aaron Carass
Abstract:
The lack of standardization is a prominent issue in magnetic resonance (MR) imaging. This often causes undesired contrast variations in the acquired images due to differences in hardware and acquisition parameters. In recent years, image synthesis-based MR harmonization with disentanglement has been proposed to compensate for the undesired contrast variations. Despite the success of existing metho…
▽ More
The lack of standardization is a prominent issue in magnetic resonance (MR) imaging. This often causes undesired contrast variations in the acquired images due to differences in hardware and acquisition parameters. In recent years, image synthesis-based MR harmonization with disentanglement has been proposed to compensate for the undesired contrast variations. Despite the success of existing methods, we argue that three major improvements can be made. First, most existing methods are built upon the assumption that multi-contrast MR images of the same subject share the same anatomy. This assumption is questionable, since different MR contrasts are specialized to highlight different anatomical features. Second, these methods often require a fixed set of MR contrasts for training (e.g., both T1-weighted and T2-weighted images), limiting their applicability. Lastly, existing methods are generally sensitive to imaging artifacts. In this paper, we present Harmonization with Attention-based Contrast, Anatomy, and Artifact Awareness (HACA3), a novel approach to address these three issues. HACA3 incorporates an anatomy fusion module that accounts for the inherent anatomical differences between MR contrasts. Furthermore, HACA3 is also robust to imaging artifacts and can be trained and applied to any set of MR contrasts. HACA3 is developed and evaluated on diverse MR datasets acquired from 21 sites with varying field strengths, scanner platforms, and acquisition protocols. Experiments show that HACA3 achieves state-of-the-art performance under multiple image quality metrics. We also demonstrate the applicability and versatility of HACA3 on downstream tasks including white matter lesion segmentation and longitudinal volumetric analyses.
△ Less
Submitted 25 April, 2023; v1 submitted 12 December, 2022;
originally announced December 2022.
-
Disentangling A Single MR Modality
Authors:
Lianrui Zuo,
Yihao Liu,
Yuan Xue,
Shuo Han,
Murat Bilgel,
Susan M. Resnick,
Jerry L. Prince,
Aaron Carass
Abstract:
Disentangling anatomical and contrast information from medical images has gained attention recently, demonstrating benefits for various image analysis tasks. Current methods learn disentangled representations using either paired multi-modal images with the same underlying anatomy or auxiliary labels (e.g., manual delineations) to provide inductive bias for disentanglement. However, these requireme…
▽ More
Disentangling anatomical and contrast information from medical images has gained attention recently, demonstrating benefits for various image analysis tasks. Current methods learn disentangled representations using either paired multi-modal images with the same underlying anatomy or auxiliary labels (e.g., manual delineations) to provide inductive bias for disentanglement. However, these requirements could significantly increase the time and cost in data collection and limit the applicability of these methods when such data are not available. Moreover, these methods generally do not guarantee disentanglement. In this paper, we present a novel framework that learns theoretically and practically superior disentanglement from single modality magnetic resonance images. Moreover, we propose a new information-based metric to quantitatively evaluate disentanglement. Comparisons over existing disentangling methods demonstrate that the proposed method achieves superior performance in both disentanglement and cross-domain image-to-image translation tasks.
△ Less
Submitted 10 May, 2022;
originally announced May 2022.
-
Coordinate Translator for Learning Deformable Medical Image Registration
Authors:
Yihao Liu,
Lianrui Zuo,
Shuo Han,
Yuan Xue,
Jerry L. Prince,
Aaron Carass
Abstract:
The majority of deep learning (DL) based deformable image registration methods use convolutional neural networks (CNNs) to estimate displacement fields from pairs of moving and fixed images. This, however, requires the convolutional kernels in the CNN to not only extract intensity features from the inputs but also understand image coordinate systems. We argue that the latter task is challenging fo…
▽ More
The majority of deep learning (DL) based deformable image registration methods use convolutional neural networks (CNNs) to estimate displacement fields from pairs of moving and fixed images. This, however, requires the convolutional kernels in the CNN to not only extract intensity features from the inputs but also understand image coordinate systems. We argue that the latter task is challenging for traditional CNNs, limiting their performance in registration tasks. To tackle this problem, we first introduce Coordinate Translator, a differentiable module that identifies matched features between the fixed and moving image and outputs their coordinate correspondences without the need for training. It unloads the burden of understanding image coordinate systems for CNNs, allowing them to focus on feature extraction. We then propose a novel deformable registration network, im2grid, that uses multiple Coordinate Translator's with the hierarchical features extracted from a CNN encoder and outputs a deformation field in a coarse-to-fine fashion. We compared im2grid with the state-of-the-art DL and non-DL methods for unsupervised 3D magnetic resonance image registration. Our experiments show that im2grid outperforms these methods both qualitatively and quantitatively.
△ Less
Submitted 31 July, 2022; v1 submitted 5 March, 2022;
originally announced March 2022.
-
Information-based Disentangled Representation Learning for Unsupervised MR Harmonization
Authors:
Lianrui Zuo,
Blake E. Dewey,
Aaron Carass,
Yihao Liu,
Yufan He,
Peter A. Calabresi,
Jerry L. Prince
Abstract:
Accuracy and consistency are two key factors in computer-assisted magnetic resonance (MR) image analysis. However, contrast variation from site to site caused by lack of standardization in MR acquisition impedes consistent measurements. In recent years, image harmonization approaches have been proposed to compensate for contrast variation in MR images. Current harmonization approaches either requi…
▽ More
Accuracy and consistency are two key factors in computer-assisted magnetic resonance (MR) image analysis. However, contrast variation from site to site caused by lack of standardization in MR acquisition impedes consistent measurements. In recent years, image harmonization approaches have been proposed to compensate for contrast variation in MR images. Current harmonization approaches either require cross-site traveling subjects for supervised training or heavily rely on site-specific harmonization models to encourage harmonization accuracy. These requirements potentially limit the application of current harmonization methods in large-scale multi-site studies. In this work, we propose an unsupervised MR harmonization framework, CALAMITI (Contrast Anatomy Learning and Analysis for MR Intensity Translation and Integration), based on information bottleneck theory. CALAMITI learns a disentangled latent space using a unified structure for multi-site harmonization without the need for traveling subjects. Our model is also able to adapt itself to harmonize MR images from a new site with fine tuning solely on images from the new site. Both qualitative and quantitative results show that the proposed method achieves superior performance compared with other unsupervised harmonization approaches.
△ Less
Submitted 24 March, 2021;
originally announced March 2021.
-
Self domain adapted network
Authors:
Yufan He,
Aaron Carass,
Lianrui Zuo,
Blake E. Dewey,
Jerry L. Prince
Abstract:
Domain shift is a major problem for deploying deep networks in clinical practice. Network performance drops significantly with (target) images obtained differently than its (source) training data. Due to a lack of target label data, most work has focused on unsupervised domain adaptation (UDA). Current UDA methods need both source and target data to train models which perform image translation (ha…
▽ More
Domain shift is a major problem for deploying deep networks in clinical practice. Network performance drops significantly with (target) images obtained differently than its (source) training data. Due to a lack of target label data, most work has focused on unsupervised domain adaptation (UDA). Current UDA methods need both source and target data to train models which perform image translation (harmonization) or learn domain-invariant features. However, training a model for each target domain is time consuming and computationally expensive, even infeasible when target domain data are scarce or source data are unavailable due to data privacy. In this paper, we propose a novel self domain adapted network (SDA-Net) that can rapidly adapt itself to a single test subject at the testing stage, without using extra data or training a UDA model. The SDA-Net consists of three parts: adaptors, task model, and auto-encoders. The latter two are pre-trained offline on labeled source images. The task model performs tasks like synthesis, segmentation, or classification, which may suffer from the domain shift problem. At the testing stage, the adaptors are trained to transform the input test image and features to reduce the domain shift as measured by the auto-encoders, and thus perform domain adaptation. We validated our method on retinal layer segmentation from different OCT scanners and T1 to T2 synthesis with T1 from different MRI scanners and with different imaging parameters. Results show that our SDA-Net, with a single test subject and a short amount of time for self adaptation at the testing stage, can achieve significant improvements.
△ Less
Submitted 6 July, 2020;
originally announced July 2020.