-
Exploring the Computational Feasibility of Direct Pseudoinversion of the Encoding Matrix for MR Image Reconstruction (Pinv-Recon)
Authors:
Kylie Yeung,
Christine Tobler,
Rolf F Schulte,
Benjamin White,
Anthony McIntyre,
Sebastien Serres,
Peter Morris,
Dorothee Auer,
Fergus V Gleeson,
Damian J Tyler,
James T Grist,
Florian Wiesinger
Abstract:
Image reconstruction in Magnetic Resonance Imaging (MRI) is fundamentally a linear inverse problem, such that the image can be recovered via explicit pseudoinversion of the encoding matrix by solving $\textbf{data} = \textbf{Encode} \times \textbf{image}$ - a method referred to here as Pinv-Recon. While the benefits of this approach were acknowledged in early studies, the field has historically fa…
▽ More
Image reconstruction in Magnetic Resonance Imaging (MRI) is fundamentally a linear inverse problem, such that the image can be recovered via explicit pseudoinversion of the encoding matrix by solving $\textbf{data} = \textbf{Encode} \times \textbf{image}$ - a method referred to here as Pinv-Recon. While the benefits of this approach were acknowledged in early studies, the field has historically favored fast Fourier transforms (FFT) and iterative techniques due to perceived computational limitations of the pseudoinversion approach. This work revisits Pinv-Recon in the context of modern hardware, software, and optimized linear algebra routines. We compare various matrix inversion strategies, assess regularization effects, and demonstrate incorporation of advanced encoding physics into a unified reconstruction framework.
While hardware advances have already significantly reduced computation time compared to earlier studies, our work further demonstrates that leveraging Cholesky decomposition and block-wise inversion leads to a two-order-of-magnitude improvement in computational efficiency over previous Singular Value Decomposition-based implementations. Moreover, we demonstrate the versatility of Pinv-Recon on diverse \textit{in vivo} datasets encompassing a range of encoding schemes, starting with low- to medium-resolution functional and metabolic imaging and extending to high-resolution cases. Our findings establish Pinv-Recon as a practical and adaptable reconstruction method that aligns with the increasing emphasis on open-source and reproducible MRI research.
△ Less
Submitted 27 May, 2025; v1 submitted 8 October, 2024;
originally announced October 2024.
-
Region of Interest focused MRI to Synthetic CT Translation using Regression and Classification Multi-task Network
Authors:
Sandeep Kaushik,
Mikael Bylund,
Cristina Cozzini,
Dattesh Shanbhag,
Steven F Petit,
Jonathan J Wyatt,
Marion I Menzel,
Carolin Pirkl,
Bhairav Mehta,
Vikas Chauhan,
Kesavadas Chandrasekharan,
Joakim Jonsson,
Tufve Nyholm,
Florian Wiesinger,
Bjoern Menze
Abstract:
In this work, we present a method for synthetic CT (sCT) generation from zero-echo-time (ZTE) MRI aimed at structural and quantitative accuracies of the image, with a particular focus on the accurate bone density value prediction. We propose a loss function that favors a spatially sparse region in the image. We harness the ability of a multi-task network to produce correlated outputs as a framewor…
▽ More
In this work, we present a method for synthetic CT (sCT) generation from zero-echo-time (ZTE) MRI aimed at structural and quantitative accuracies of the image, with a particular focus on the accurate bone density value prediction. We propose a loss function that favors a spatially sparse region in the image. We harness the ability of a multi-task network to produce correlated outputs as a framework to enable localisation of region of interest (RoI) via classification, emphasize regression of values within RoI and still retain the overall accuracy via global regression. The network is optimized by a composite loss function that combines a dedicated loss from each task. We demonstrate how the multi-task network with RoI focused loss offers an advantage over other configurations of the network to achieve higher accuracy of performance. This is relevant to sCT where failure to accurately estimate high Hounsfield Unit values of bone could lead to impaired accuracy in clinical applications. We compare the dose calculation maps from the proposed sCT and the real CT in a radiation therapy treatment planning setup.
△ Less
Submitted 25 October, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Attenuation Coefficient Estimation for PET/MRI With Bayesian Deep Learning pseudo-CT and Maximum Likelihood Estimation of Activity and Attenuation
Authors:
Andrew P. Leynes,
Sangtae P. Ahn,
Kristen A. Wangerin,
Sandeep S. Kaushik,
Florian Wiesinger,
Thomas A. Hope,
Peder E. Z. Larson
Abstract:
A major remaining challenge for magnetic resonance-based attenuation correction methods (MRAC) is their susceptibility to sources of MRI artifacts (e.g. implants, motion) and uncertainties due to the limitations of MRI contrast (e.g. accurate bone delineation and density, and separation of air/bone). We propose using a Bayesian deep convolutional neural network that, in addition to generating an i…
▽ More
A major remaining challenge for magnetic resonance-based attenuation correction methods (MRAC) is their susceptibility to sources of MRI artifacts (e.g. implants, motion) and uncertainties due to the limitations of MRI contrast (e.g. accurate bone delineation and density, and separation of air/bone). We propose using a Bayesian deep convolutional neural network that, in addition to generating an initial pseudo-CT from MR data, also produces uncertainty estimates of the pseudo-CT to quantify the limitations of the MR data. These outputs are combined with MLAA reconstruction that uses the PET emission data to improve the attenuation maps. With the proposed approach (UpCT-MLAA), we demonstrate accurate estimation of PET uptake in pelvic lesions and show recovery of metal implants. In patients without implants, UpCT-MLAA had acceptable but slightly higher RMSE than Zero-echo-time and Dixon Deep pseudo-CT when compared to CTAC. In patients with metal implants, MLAA recovered the metal implant; however, anatomy outside the implant region was obscured by noise and crosstalk artifacts. Attenuation coefficients from the pseudo-CT from Dixon MRI were accurate in normal anatomy; however, the metal implant region was estimated to have attenuation coefficients of air. UpCT-MLAA estimated attenuation coefficients of metal implants alongside accurate anatomic depiction outside of implant regions.
△ Less
Submitted 13 October, 2021; v1 submitted 10 January, 2020;
originally announced January 2020.