Rapid Artefact Removal and H&E-Stained Tissue Segmentation
Authors:
B. A. Schreiber,
J. Denholm,
F. Jaeckle,
M. J. Arends,
K. M. Branson,
C. -B. Schönlieb,
E. J. Soilleux
Abstract:
We present an innovative method for rapidly segmenting hematoxylin and eosin (H&E)-stained tissue in whole-slide images (WSIs) that eliminates a wide range of undesirable artefacts such as pen marks and scanning artefacts. Our method involves taking a single-channel representation of a lowmagnification RGB overview of the WSI in which the pixel values are bimodally distributed such that H&E-staine…
▽ More
We present an innovative method for rapidly segmenting hematoxylin and eosin (H&E)-stained tissue in whole-slide images (WSIs) that eliminates a wide range of undesirable artefacts such as pen marks and scanning artefacts. Our method involves taking a single-channel representation of a lowmagnification RGB overview of the WSI in which the pixel values are bimodally distributed such that H&E-stained tissue is easily distinguished from both background and a wide variety of artefacts. We demonstrate our method on 30 WSIs prepared from a wide range of institutions and WSI digital scanners, each containing substantial artefacts, and compare it to segmentations provided by Otsu thresholding and Histolab tissue segmentation and pen filtering tools. We found that our method segmented the tissue and fully removed all artefacts in 29 out of 30 WSIs, whereas Otsu thresholding failed to remove any artefacts, and the Histolab pen filtering tools only partially removed the pen marks. The beauty of our approach lies in its simplicity: manipulating RGB colour space and using Otsu thresholding allows for the segmentation of H&E-stained tissue and the rapid removal of artefacts without the need for machine learning or parameter tuning.
△ Less
Submitted 19 December, 2023; v1 submitted 25 August, 2023;
originally announced August 2023.
-
CRANE: a 10 Degree-of-Freedom, Tele-surgical System for Dexterous Manipulation within Imaging Bores
Authors:
Dimitri A. Schreiber,
Zhaowei Yu,
Hanpeng Jiang,
Taylor Henderson,
Guosong Li,
Julie Yu,
Renjie Zhu,
Alexander M. Norbash,
Michael C. Yip
Abstract:
Physicians perform minimally invasive percutaneous procedures under Computed Tomography (CT) image guidance both for the diagnosis and treatment of numerous diseases. For these procedures performed within Computed Tomography Scanners, robots can enable physicians to more accurately target sub-dermal lesions while increasing safety. However, existing robots for this application have limited dexteri…
▽ More
Physicians perform minimally invasive percutaneous procedures under Computed Tomography (CT) image guidance both for the diagnosis and treatment of numerous diseases. For these procedures performed within Computed Tomography Scanners, robots can enable physicians to more accurately target sub-dermal lesions while increasing safety. However, existing robots for this application have limited dexterity, workspace, or accuracy. This paper describes the design, manufacture, and performance of a highly dexterous, low-profile, 8+2 Degree-ofFreedom (DoF) robotic arm for CT guided percutaneous needle biopsy. In this article, we propose CRANE: CT Robot and Needle Emplacer. The design focuses on system dexterity with high accuracy: extending physicians' ability to manipulate and insert needles within the scanner bore while providing the high accuracy possible with a robot. We also propose and validate a system architecture and control scheme for low profile and highly accurate image-guided robotics, that meets the clinical requirements for target accuracy during an in-situ evaluation. The accuracy is additionally evaluated through a trajectory tracking evaluation resulting in <0.2mm and <0.71degree tracking error. Finally, we present a novel needle driving and grasping mechanism with controlling electronics that provides simple manufacturing, sterilization, and adaptability to accommodate different sizes and types of needles.
△ Less
Submitted 17 March, 2022; v1 submitted 27 September, 2021;
originally announced September 2021.
-
Anisotropic 3D Multi-Stream CNN for Accurate Prostate Segmentation from Multi-Planar MRI
Authors:
Anneke Meyer,
Grzegorz Chlebus,
Marko Rak,
Daniel Schindele,
Martin Schostak,
Bram van Ginneken,
Andrea Schenk,
Hans Meine,
Horst K. Hahn,
Andreas Schreiber,
Christian Hansen
Abstract:
Background and Objective: Accurate and reliable segmentation of the prostate gland in MR images can support the clinical assessment of prostate cancer, as well as the planning and monitoring of focal and loco-regional therapeutic interventions. Despite the availability of multi-planar MR scans due to standardized protocols, the majority of segmentation approaches presented in the literature consid…
▽ More
Background and Objective: Accurate and reliable segmentation of the prostate gland in MR images can support the clinical assessment of prostate cancer, as well as the planning and monitoring of focal and loco-regional therapeutic interventions. Despite the availability of multi-planar MR scans due to standardized protocols, the majority of segmentation approaches presented in the literature consider the axial scans only. Methods: We propose an anisotropic 3D multi-stream CNN architecture, which processes additional scan directions to produce a higher-resolution isotropic prostate segmentation. We investigate two variants of our architecture, which work on two (dual-plane) and three (triple-plane) image orientations, respectively. We compare them with the standard baseline (single-plane) used in literature, i.e., plain axial segmentation. To realize a fair comparison, we employ a hyperparameter optimization strategy to select optimal configurations for the individual approaches. Results: Training and evaluation on two datasets spanning multiple sites obtain statistical significant improvement over the plain axial segmentation ($p<0.05$ on the Dice similarity coefficient). The improvement can be observed especially at the base ($0.898$ single-plane vs. $0.906$ triple-plane) and apex ($0.888$ single-plane vs. $0.901$ dual-plane). Conclusion: This study indicates that models employing two or three scan directions are superior to plain axial segmentation. The knowledge of precise boundaries of the prostate is crucial for the conservation of risk structures. Thus, the proposed models have the potential to improve the outcome of prostate cancer diagnosis and therapies.
△ Less
Submitted 2 December, 2020; v1 submitted 23 September, 2020;
originally announced September 2020.
-
A Boolean Control Network Approach to the Formal Verification of Feedback Context-Aware Pervasive Systems
Authors:
Fabio A. Schreiber,
Maria Elena Valcher
Abstract:
The emergence of Context-aware systems in the domains of autonomic, monitoring, and safety-critical applications asks for the definition of methods to formally assess their correctness and dependability properties. Many of these properties are common to Automatic Control systems, a field that developed well established analysis and design techniques to formalize and investigate them. In this paper…
▽ More
The emergence of Context-aware systems in the domains of autonomic, monitoring, and safety-critical applications asks for the definition of methods to formally assess their correctness and dependability properties. Many of these properties are common to Automatic Control systems, a field that developed well established analysis and design techniques to formalize and investigate them. In this paper, we use Boolean Control Networks, to discuss some properties of a feedback Context-aware system in a case study based on a healthcare management example.
△ Less
Submitted 6 July, 2020;
originally announced July 2020.
-
Formal assessment of some properties of Context-Aware Systems
Authors:
Fabio A. Schreiber,
Maria Elena Valcher
Abstract:
Context-Aware systems are becoming useful components in autonomic and monitoring applications and the assessment of their properties is an important step towards reliable implementation, especially in safety-critical applications. In this paper, using an avalanche/landslide alert system as a running example, we propose a technique, based on Boolean Control Networks, to verify that the system dynam…
▽ More
Context-Aware systems are becoming useful components in autonomic and monitoring applications and the assessment of their properties is an important step towards reliable implementation, especially in safety-critical applications. In this paper, using an avalanche/landslide alert system as a running example, we propose a technique, based on Boolean Control Networks, to verify that the system dynamics has stable equilibrium states, corresponding to constant inputs, and hence it does not exhibit oscillatory behaviors, and to establish other useful properties in order to implement a precise and timely alarm system.
△ Less
Submitted 1 May, 2020;
originally announced May 2020.