-
PUUMA (Placental patch and whole-Uterus dual-branch U-Mamba-based Architecture): Functional MRI Prediction of Gestational Age at Birth and Preterm Risk
Authors:
Diego Fajardo-Rojas,
Levente Baljer,
Jordina Aviles Verdera,
Megan Hall,
Daniel Cromb,
Mary A. Rutherford,
Lisa Story,
Emma C. Robinson,
Jana Hutter
Abstract:
Preterm birth is a major cause of mortality and lifelong morbidity in childhood. Its complex and multifactorial origins limit the effectiveness of current clinical predictors and impede optimal care. In this study, a dual-branch deep learning architecture (PUUMA) was developed to predict gestational age (GA) at birth using T2* fetal MRI data from 295 pregnancies, encompassing a heterogeneous and i…
▽ More
Preterm birth is a major cause of mortality and lifelong morbidity in childhood. Its complex and multifactorial origins limit the effectiveness of current clinical predictors and impede optimal care. In this study, a dual-branch deep learning architecture (PUUMA) was developed to predict gestational age (GA) at birth using T2* fetal MRI data from 295 pregnancies, encompassing a heterogeneous and imbalanced population. The model integrates both global whole-uterus and local placental features. Its performance was benchmarked against linear regression using cervical length measurements obtained by experienced clinicians from anatomical MRI and other Deep Learning architectures. The GA at birth predictions were assessed using mean absolute error. Accuracy, sensitivity, and specificity were used to assess preterm classification. Both the fully automated MRI-based pipeline and the cervical length regression achieved comparable mean absolute errors (3 weeks) and good sensitivity (0.67) for detecting preterm birth, despite pronounced class imbalance in the dataset. These results provide a proof of concept for automated prediction of GA at birth from functional MRI, and underscore the value of whole-uterus functional imaging in identifying at-risk pregnancies. Additionally, we demonstrate that manual, high-definition cervical length measurements derived from MRI, not currently routine in clinical practice, offer valuable predictive information. Future work will focus on expanding the cohort size and incorporating additional organ-specific imaging to improve generalisability and predictive performance.
△ Less
Submitted 8 September, 2025;
originally announced September 2025.
-
An automated pipeline for quantitative T2* fetal body MRI and segmentation at low field
Authors:
Kelly Payette,
Alena Uus,
Jordina Aviles Verdera,
Carla Avena Zampieri,
Megan Hall,
Lisa Story,
Maria Deprez,
Mary A. Rutherford,
Joseph V. Hajnal,
Sebastien Ourselin,
Raphael Tomi-Tricot,
Jana Hutter
Abstract:
Fetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing to…
▽ More
Fetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we introduce a semi-automatic pipeline using quantitative MRI for the fetal body at low field strength resulting in fast and detailed quantitative T2* relaxometry analysis of all major fetal body organs. Multi-echo dynamic sequences of the fetal body were acquired and reconstructed into a single high-resolution volume using deformable slice-to-volume reconstruction, generating both structural and quantitative T2* 3D volumes. A neural network trained using a semi-supervised approach was created to automatically segment these fetal body 3D volumes into ten different organs (resulting in dice values > 0.74 for 8 out of 10 organs). The T2* values revealed a strong relationship with GA in the lungs, liver, and kidney parenchyma (R^2>0.5). This pipeline was used successfully for a wide range of GAs (17-40 weeks), and is robust to motion artefacts. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning.
△ Less
Submitted 9 August, 2023;
originally announced August 2023.
-
Self-supervised Recurrent Neural Network for 4D Abdominal and In-utero MR Imaging
Authors:
Tong Zhang,
Laurence H. Jackson,
Alena Uus,
James R. Clough,
Lisa Story,
Mary A. Rutherford,
Joseph V. Hajnal,
Maria Deprez
Abstract:
Accurately estimating and correcting the motion artifacts are crucial for 3D image reconstruction of the abdominal and in-utero magnetic resonance imaging (MRI). The state-of-art methods are based on slice-to-volume registration (SVR) where multiple 2D image stacks are acquired in three orthogonal orientations. In this work, we present a novel reconstruction pipeline that only needs one orientatio…
▽ More
Accurately estimating and correcting the motion artifacts are crucial for 3D image reconstruction of the abdominal and in-utero magnetic resonance imaging (MRI). The state-of-art methods are based on slice-to-volume registration (SVR) where multiple 2D image stacks are acquired in three orthogonal orientations. In this work, we present a novel reconstruction pipeline that only needs one orientation of 2D MRI scans and can reconstruct the full high-resolution image without masking or registration steps. The framework consists of two main stages: the respiratory motion estimation using a self-supervised recurrent neural network, which learns the respiratory signals that are naturally embedded in the asymmetry relationship of the neighborhood slices and cluster them according to a respiratory state. Then, we train a 3D deconvolutional network for super-resolution (SR) reconstruction of the sparsely selected 2D images using integrated reconstruction and total variation loss. We evaluate the classification accuracy on 5 simulated images and compare our results with the SVR method in adult abdominal and in-utero MRI scans. The results show that the proposed pipeline can accurately estimate the respiratory state and reconstruct 4D SR volumes with better or similar performance to the 3D SVR pipeline with less than 20\% sparsely selected slices. The method has great potential to transform the 4D abdominal and in-utero MRI in clinical practice.
△ Less
Submitted 28 August, 2019;
originally announced August 2019.
-
Deformable Slice-to-Volume Registration for Motion Correction in Fetal Body MRI
Authors:
Alena Uus,
Tong Zhang,
Laurence H. Jackson,
Thomas A. Roberts,
Mary A. Rutherford,
Joseph V. Hajnal,
Maria Deprez
Abstract:
In in-utero MRI, motion correction for fetal body and placenta poses a particular challenge due to the presence of local non-rigid transformations of organs caused by bending and stretching. The existing slice-to-volume registration (SVR) reconstruction methods are widely employed for motion correction of fetal brain that undergoes only rigid transformation. However, for reconstruction of fetal bo…
▽ More
In in-utero MRI, motion correction for fetal body and placenta poses a particular challenge due to the presence of local non-rigid transformations of organs caused by bending and stretching. The existing slice-to-volume registration (SVR) reconstruction methods are widely employed for motion correction of fetal brain that undergoes only rigid transformation. However, for reconstruction of fetal body and placenta, rigid registration cannot resolve the issue of misregistrations due to deformable motion, resulting in degradation of features in the reconstructed volume. We propose a Deformable SVR (DSVR), a novel approach for non-rigid motion correction of fetal MRI based on a hierarchical deformable SVR scheme to allow high resolution reconstruction of the fetal body and placenta. Additionally, a robust scheme for structure-based rejection of outliers minimises the impact of registration errors. The improved performance of DSVR in comparison to SVR and patch-to-volume registration (PVR) methods is quantitatively demonstrated in simulated experiments and 20 fetal MRI datasets from 28-31 weeks gestational age (GA) range with varying degree of motion corruption. In addition, we present qualitative evaluation of 100 fetal body cases from 20-34 weeks GA range.
△ Less
Submitted 28 February, 2020; v1 submitted 20 June, 2019;
originally announced June 2019.