Self-supervised Deep Learning for Denoising in Ultrasound Microvascular Imaging
Authors:
Lijie Huang,
Jingyi Yin,
Jingke Zhang,
U-Wai Lok,
Ryan M. DeRuiter,
Jieyang Jin,
Kate M. Knoll,
Kendra E. Petersen,
James D. Krier,
Xiang-yang Zhu,
Gina K. Hesley,
Kathryn A. Robinson,
Andrew J. Bentall,
Thomas D. Atwell,
Andrew D. Rule,
Lilach O. Lerman,
Shigao Chen,
Chengwu Huang
Abstract:
Ultrasound microvascular imaging (UMI) is often hindered by low signal-to-noise ratio (SNR), especially in contrast-free or deep tissue scenarios, which impairs subsequent vascular quantification and reliable disease diagnosis. To address this challenge, we propose Half-Angle-to-Half-Angle (HA2HA), a self-supervised denoising framework specifically designed for UMI. HA2HA constructs training pairs…
▽ More
Ultrasound microvascular imaging (UMI) is often hindered by low signal-to-noise ratio (SNR), especially in contrast-free or deep tissue scenarios, which impairs subsequent vascular quantification and reliable disease diagnosis. To address this challenge, we propose Half-Angle-to-Half-Angle (HA2HA), a self-supervised denoising framework specifically designed for UMI. HA2HA constructs training pairs from complementary angular subsets of beamformed radio-frequency (RF) blood flow data, across which vascular signals remain consistent while noise varies. HA2HA was trained using in-vivo contrast-free pig kidney data and validated across diverse datasets, including contrast-free and contrast-enhanced data from pig kidneys, as well as human liver and kidney. An improvement exceeding 15 dB in both contrast-to-noise ratio (CNR) and SNR was observed, indicating a substantial enhancement in image quality. In addition to power Doppler imaging, denoising directly in the RF domain is also beneficial for other downstream processing such as color Doppler imaging (CDI). CDI results of human liver derived from the HA2HA-denoised signals exhibited improved microvascular flow visualization, with a suppressed noisy background. HA2HA offers a label-free, generalizable, and clinically applicable solution for robust vascular imaging in both contrast-free and contrast-enhanced UMI.
△ Less
Submitted 7 July, 2025;
originally announced July 2025.
Optimizing In Vivo Data Acquisition for Robust Clinical Microvascular Imaging Using Ultrasound Localization Microscopy
Authors:
Chengwu Huang,
U-Wai Lok,
Jingke Zhang,
Xiang Yang Zhu,
James D. Krier,
Amy Stern,
Kate M. Knoll,
Kendra E. Petersen,
Kathryn A. Robinson,
Gina K. Hesley,
Andrew J. Bentall,
Thomas D. Atwell,
Andrew D. Rule,
Lilach O. Lerman,
Shigao Chen
Abstract:
Ultrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of…
▽ More
Ultrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of variations underscore the need to optimize MB dosage, data acquisition timing, and imaging settings in order to standardize and optimize ULM of microvasculature. This pilot study investigated temporal changes in MB signals during bolus injections in both pig and human models to optimize data acquisition for clinical ULM. Quantitative indices were developed to evaluate MB signal quality, guiding selection of acquisition timing that balances the MB localization quality and adequate MB counts. The effects of transmitted voltage and dosage were also explored. In the pig model, a relatively short window (approximately 10 seconds) for optimal acquisition was identified during the rapid wash-out phase, highlighting the need for real-time MB signal monitoring during data acquisition. The slower wash-out phase in humans allowed for a more flexible imaging window of 1-2 minutes, while trade-offs were observed between localization quality and MB density (or acquisition length) at different wash-out phase timings. Guided by these findings, robust ULM imaging was achieved in both pig and human kidneys using a short period of data acquisition, demonstrating its feasibility in clinical practice. This study provides insights into optimizing data acquisition for consistent and reproducible ULM, paving the way for its standardization and broader clinical applications.
△ Less
Submitted 23 December, 2024;
originally announced December 2024.