Skip to main content

Showing 1–5 of 5 results for author: Nayak, K S

Searching in archive eess. Search in all archives.
.
  1. arXiv:2505.20568  [pdf

    eess.IV

    A Feasibility Study of Task-Based fMRI at 0.55 T

    Authors: Parsa Razmara, Takfarinas Medani, Anand A. Joshi, Majid Abbasi Sisara, Ye Tian, Sophia X. Cui, Justin P. Haldar, Krishna S. Nayak, Richard M. Leahy

    Abstract: 0.55T MRI offers advantages compared to conventional field strengths, including reduced susceptibility artifacts and better compatibility with simultaneous EEG recordings. However, reliable task-based fMRI at 0.55T has not been significantly demonstrated. In this study, we establish a robust task-based fMRI protocol and analysis pipeline at 0.55T that achieves full brain coverage and results compa… ▽ More

    Submitted 26 May, 2025; originally announced May 2025.

    Comments: Presented at the ISMRM 2025 Annual Meeting, Honolulu (#0491)

  2. arXiv:2102.07896  [pdf, other

    eess.SP cs.SD eess.AS eess.IV

    A multispeaker dataset of raw and reconstructed speech production real-time MRI video and 3D volumetric images

    Authors: Yongwan Lim, Asterios Toutios, Yannick Bliesener, Ye Tian, Sajan Goud Lingala, Colin Vaz, Tanner Sorensen, Miran Oh, Sarah Harper, Weiyi Chen, Yoonjeong Lee, Johannes Töger, Mairym Lloréns Montesserin, Caitlin Smith, Bianca Godinez, Louis Goldstein, Dani Byrd, Krishna S. Nayak, Shrikanth S. Narayanan

    Abstract: Real-time magnetic resonance imaging (RT-MRI) of human speech production is enabling significant advances in speech science, linguistics, bio-inspired speech technology development, and clinical applications. Easy access to RT-MRI is however limited, and comprehensive datasets with broad access are needed to catalyze research across numerous domains. The imaging of the rapidly moving articulators… ▽ More

    Submitted 15 February, 2021; originally announced February 2021.

    Comments: 27 pages, 6 figures, 5 tables, submitted to Nature Scientific Data

  3. arXiv:2102.07271  [pdf, other

    eess.IV cs.CV

    Attention-gated convolutional neural networks for off-resonance correction of spiral real-time MRI

    Authors: Yongwan Lim, Shrikanth S. Narayanan, Krishna S. Nayak

    Abstract: Spiral acquisitions are preferred in real-time MRI because of their efficiency, which has made it possible to capture vocal tract dynamics during natural speech. A fundamental limitation of spirals is blurring and signal loss due to off-resonance, which degrades image quality at air-tissue boundaries. Here, we present a new CNN-based off-resonance correction method that incorporates an attention-g… ▽ More

    Submitted 14 February, 2021; originally announced February 2021.

    Comments: 8 pages, 4 figures, 1 table

    Journal ref: 28th Int. Soc. Magn. Reson. Med. (ISMRM) Scientific Sessions, 2020, p.1005

  4. arXiv:2001.09427  [pdf, other

    eess.IV

    Deblurring for Spiral Real-Time MRI Using Convolutional Neural Networks

    Authors: Yongwan Lim, Shrikanth S Narayanan, Krishna S Nayak

    Abstract: Spiral acquisitions are preferred in real-time MRI because of their time efficiency. A fundamental limitation of spirals is image blurring due to off-resonance, which degrades image quality significantly at air-tissue boundaries. Here, we demonstrate a simple CNN-based deblurring method for spiral real-time MRI of human speech production. We show the CNN-based deblurring is capable of restoring bl… ▽ More

    Submitted 29 May, 2020; v1 submitted 26 January, 2020; originally announced January 2020.

    Comments: Presented at International Conference on Medical Imaging with Deep Learning (MIDL 2020) (A short conference paper of the full journal paper in the earlier submission version)

    Report number: MIDL/2020/ExtendedAbstract/zYareJYs8Z

  5. arXiv:1907.13261  [pdf, other

    eess.IV cs.CV

    Robust Autocalibrated Structured Low-Rank EPI Ghost Correction

    Authors: Rodrigo A. Lobos, W. Scott Hoge, Ahsan Javed, Congyu Liao, Kawin Setsompop, Krishna S. Nayak, Justin P. Haldar

    Abstract: Purpose: We propose and evaluate a new structured low-rank method for EPI ghost correction called Robust Autocalibrated LORAKS (RAC-LORAKS). The method can be used to suppress EPI ghosts arising from the differences between different readout gradient polarities and/or the differences between different shots. It does not require conventional EPI navigator signals, and is robust to imperfect autocal… ▽ More

    Submitted 1 October, 2020; v1 submitted 30 July, 2019; originally announced July 2019.