-
Optimization of a Commercial Injection-Moulded component by Using DOE and Simulation
Authors:
Mandana Kariminejad,
David Tormey,
Saif Huq,
Jim Morrison,
Jeff Redmond,
Carlos Souto,
Marion McAfee
Abstract:
Injection moulding is an important industry, providing a significant percentage of the demand for plastic products throughout the world. The process consists of many variables which directly or indirectly influence the part quality and cycle time. The first step in optimizing the process parameters is identifying the most significant variables affecting the desired output. For this purpose, variou…
▽ More
Injection moulding is an important industry, providing a significant percentage of the demand for plastic products throughout the world. The process consists of many variables which directly or indirectly influence the part quality and cycle time. The first step in optimizing the process parameters is identifying the most significant variables affecting the desired output. For this purpose, various Design of Experiments methods (DOE) have been developed to investigate the effect of the experimental variables on the output and predict the required settings to achieve the optimal value of the output. In this study we investigate the application of DOE for a commercial injection moulded component which suffers from a long cycle time and high shrinkage. The Taguchi method has been used to analyze the effect of four input variables on the two output variables: cycle time and shrinkage. The component has been simulated in the Moldflow software to validate the predicted output and optimized settings of the variables from the DOE. A comparison of the simulation result and the predicted value from the DOE illustrated good accordance. The calculated optimal setting with the Taguchi method reduced the cycle time from the 40s to about 23s and met the shrinkage criteria for this commercial part.
△ Less
Submitted 27 January, 2023;
originally announced January 2023.
-
Comparison of Intelligent Approaches for Cycle Time Prediction in Injection Moulding of a Medical Device Product
Authors:
Mandana Kariminejad,
David Tormey,
Saif Huq,
Jim Morrison,
Marion McAfee
Abstract:
Injection moulding is an increasingly automated industrial process, particularly when used for the production of high-value precision components such as polymeric medical devices. In such applications, achieving stringent product quality demands whilst also ensuring a highly efficient process can be challenging. Cycle time is one of the most critical factors which directly affects the throughput r…
▽ More
Injection moulding is an increasingly automated industrial process, particularly when used for the production of high-value precision components such as polymeric medical devices. In such applications, achieving stringent product quality demands whilst also ensuring a highly efficient process can be challenging. Cycle time is one of the most critical factors which directly affects the throughput rate of the process and hence is a key indicator of process efficiency. In this work, we examine a production data set from a real industrial injection moulding process for manufacture of a high precision medical device. The relationship between the process input variables and the resulting cycle time is mapped with an artificial neural network (ANN) and an adaptive neuro-fuzzy system (ANFIS). The predictive performance of different training methods and neuron numbers in ANN and the impact of model type and the numbers of membership functions in ANFIS has been investigated. The strengths and limitations of the approaches are presented and the further research and development needed to ensure practical on-line use of these methods for dynamic process optimisation in the industrial process are discussed.
△ Less
Submitted 3 February, 2022;
originally announced February 2022.
-
Focal Loss Analysis of Nerve Fiber Layer Reflectance for Glaucoma Diagnosis
Authors:
Ou Tan,
Liang Liu,
Qisheng You,
Jie Wang,
Aiyin Chen,
Eliesa Ing,
John C. Morrison,
Yali Jia,
David Huang
Abstract:
Purpose: To evaluate nerve fiber layer (NFL) reflectance for glaucoma diagnosis. Methods: Participants were imaged with 4.5X4.5-mm volumetric disc scans using spectral-domain optical coherence tomography (OCT). The normalized NFL reflectance map was processed by an azimuthal filter to reduce directional reflectance bias due to variation of beam incidence angle. The peripapillary area of the map wa…
▽ More
Purpose: To evaluate nerve fiber layer (NFL) reflectance for glaucoma diagnosis. Methods: Participants were imaged with 4.5X4.5-mm volumetric disc scans using spectral-domain optical coherence tomography (OCT). The normalized NFL reflectance map was processed by an azimuthal filter to reduce directional reflectance bias due to variation of beam incidence angle. The peripapillary area of the map was divided into 160 superpixels. Average reflectance was the mean of superpixel reflectance. Low-reflectance superpixels were identified as those with NFL reflectance below the 5 percentile normative cutoff. Focal reflectance loss was measure by summing loss in low-reflectance superpixels. Results: Thirty-five normal, 30 pre-perimetric and 35 perimetric glaucoma participants were enrolled. Azimuthal filtering improved the repeatability of the normalized NFL reflectance, as measured by the pooled superpixel standard deviation (SD), from 0.73 to 0.57 dB (p<0.001, paired t-test) and reduced the population SD from 2.14 to 1.78 dB (p<0.001, t-test). Most glaucomatous reflectance maps showed characteristic patterns of contiguous wedge or diffuse defects. Focal NFL reflectance loss had significantly higher diagnostic sensitivity than the best NFL thickness parameter (overall, inferior, or focal loss volume): 53% v. 23% (p=0.027) in PPG eyes and 100% v. 80% (p=0.023) in PG eyes, with the specificity fixed at 99%. Conclusions: Azimuthal filtering reduces the variability of NFL reflectance measurements. Focal NFL reflectance loss has excellent glaucoma diagnostic accuracy compared to the standard NFL thickness parameters. The reflectance map may be useful for localizing NFL defects.
△ Less
Submitted 24 June, 2020;
originally announced June 2020.
-
AxoNet: an AI-based tool to count retinal ganglion cell axons
Authors:
Matthew D. Ritch,
Bailey G. Hannon,
A. Thomas Read,
Andrew J. Feola,
Grant A. Cull,
Juan Reynaud,
John C. Morrison,
Claude F. Burgoyne,
Machelle T. Pardue,
C. Ross Ethier
Abstract:
Goal: In this work, we develop a robust, extensible tool to automatically and accurately count retinal ganglion cell axons in images of optic nerve tissue from various animal models of glaucoma. Methods: The U-Net convolutional neural network architecture was adapted to learn pixelwise axon count density estimates, which were then integrated over the image area to determine axon counts. The tool,…
▽ More
Goal: In this work, we develop a robust, extensible tool to automatically and accurately count retinal ganglion cell axons in images of optic nerve tissue from various animal models of glaucoma. Methods: The U-Net convolutional neural network architecture was adapted to learn pixelwise axon count density estimates, which were then integrated over the image area to determine axon counts. The tool, termed AxoNet, was trained and evaluated using a dataset containing images of optic nerve regions randomly selected from complete cross sections of intact rat optic nerves and manually annotated for axon count and location. Both control and damaged optic nerves were used. This rat-trained network was then applied to a separate dataset of non-human primate (NHP) optic nerve images. AxoNet was then compared to two existing automated axon counting tools, AxonMaster and AxonJ, using both datasets. Results: AxoNet outperformed the existing tools on both the rat and NHP optic nerve datasets as judged by mean absolute error, R2 values when regressing automated vs. manual counts, and Bland-Altman analysis. Conclusion: The proposed tool allows for accurate quantification of axon numbers as a measure of glaucomatous damage. AxoNet is robust to variations in optic nerve tissue damage extent, image quality, and species of mammal. Significance: The deep learning method does not rely on hand-crafted image features for axon recognition. Therefore, this approach is not species-specific and can be extended to quantify additional optic nerve features. It will aid evaluation of optic nerve changes in glaucoma and potentially other neurodegenerative diseases.
△ Less
Submitted 7 August, 2019;
originally announced August 2019.