BMAR: Barometric and Motion-based Alignment and Refinement for Offline Signal Synchronization across Devices
Authors:
Manuel Meier,
Christian Holz
Abstract:
A requirement of cross-modal signal processing is accurate signal alignment. Though simple on a single device, accurate signal synchronization becomes challenging as soon as multiple devices are involved, such as during activity monitoring, health tracking, or motion capture - particularly outside controlled scenarios where data collection must be standalone, low-power, and support long runtimes.…
▽ More
A requirement of cross-modal signal processing is accurate signal alignment. Though simple on a single device, accurate signal synchronization becomes challenging as soon as multiple devices are involved, such as during activity monitoring, health tracking, or motion capture - particularly outside controlled scenarios where data collection must be standalone, low-power, and support long runtimes. In this paper, we present BMAR, a novel synchronization method that operates purely based on recorded signals and is thus suitable for offline processing. BMAR needs no wireless communication between devices during runtime and does not require any specific user input, action, or behavior. BMAR operates on the data from devices worn by the same person that record barometric pressure and acceleration - inexpensive, low-power, and thus commonly included sensors in today's wearable devices. In its first stage, BMAR verifies that two recordings were acquired simultaneously and pre-aligns all data traces. In a second stage, BMAR refines the alignment using acceleration measurements while accounting for clock skew between devices. In our evaluation, three to five body-worn devices recorded signals from the wearer for up to ten hours during a series of activities. BMAR synchronized all signal recordings with a median error of 33.4 ms and reliably rejected non-overlapping signal traces. The worst-case activity was sleeping, where BMAR's second stage could not exploit motion for refinement and, thus, aligned traces with a median error of 3.06 s.
△ Less
Submitted 27 January, 2025;
originally announced January 2025.
-
Tri-Spectral PPG: Robust Reflective Photoplethysmography by Fusing Multiple Wavelengths for Cardiac Monitoring
Authors:
Manuel Meier,
Berken Utku Demirel,
Christian Holz
Abstract:
Multi-channel photoplethysmography (PPG) sensors have found widespread adoption in wearable devices for monitoring cardiac health. Channels thereby serve different functions -- whereas green is commonly used for metrics such as heart rate and heart rate variability, red and infrared are commonly used for pulse oximetry. In this paper, we introduce a novel method that simultaneously fuses multi-cha…
▽ More
Multi-channel photoplethysmography (PPG) sensors have found widespread adoption in wearable devices for monitoring cardiac health. Channels thereby serve different functions -- whereas green is commonly used for metrics such as heart rate and heart rate variability, red and infrared are commonly used for pulse oximetry. In this paper, we introduce a novel method that simultaneously fuses multi-channel PPG signals into a single recovered PPG signal that can be input to further processing. Via signal fusion, our learning-based method compensates for the artifacts that affect wavelengths to different extents, such as motion and ambient light changes. We evaluate our method on a novel dataset of multi-channel PPG recordings and electrocardiogram recordings for reference from 10 participants over the course of 13 hours during real-world activities outside the laboratory. Using the fusion PPG signal our method recovered, participants' heart rates can be calculated with a mean error of 4.5\,bpm (23\% lower than from green PPG signals at 5.9\,bpm).
△ Less
Submitted 23 December, 2024;
originally announced December 2024.
-
Robust Heart Rate Detection via Multi-Site Photoplethysmography
Authors:
Manuel Meier,
Christian Holz
Abstract:
Smartwatches have become popular for monitoring physiological parameters outside clinical settings. Using reflective photoplethysmography (PPG) sensors, such watches can non-invasively estimate heart rate (HR) in everyday environments and throughout a patient's day. However, achieving consistently high accuracy remains challenging, particularly during moments of increased motion or due to varying…
▽ More
Smartwatches have become popular for monitoring physiological parameters outside clinical settings. Using reflective photoplethysmography (PPG) sensors, such watches can non-invasively estimate heart rate (HR) in everyday environments and throughout a patient's day. However, achieving consistently high accuracy remains challenging, particularly during moments of increased motion or due to varying device placement. In this paper, we introduce a novel sensor fusion method for estimating HR that flexibly combines samples from multiple PPG sensors placed across the patient's body, including wrist, ankle, head, and sternum (chest). Our method first estimates signal quality across all inputs to dynamically integrate them into a joint and robust PPG signal for HR estimation. We evaluate our method on a novel dataset of PPG and ECG recordings from 14 participants who engaged in real-world activities outside the laboratory over the course of a whole day. Our method achieves a mean HR error of 2.4\,bpm, which is 46\% lower than the mean error of the best-performing single device (4.4\,bpm, head).
△ Less
Submitted 23 December, 2024;
originally announced December 2024.
-
Respiro: Continuous Respiratory Rate Monitoring During Motion via Wearable Ultra-Wideband Radar
Authors:
Sebastian Reidy,
Manuel Meier,
Christian Holz
Abstract:
Deviations in respiratory rate often precede abnormalities in other vital signs. However, continuously monitoring respiratory rates outside clinical settings remains challenging due to the obtrusive nature and sensitivity to body motions in existing monitoring approaches. In this study, we propose a single-point-of-contact wearable device that leverages off-the-shelf, consumer-grade ultra-wideband…
▽ More
Deviations in respiratory rate often precede abnormalities in other vital signs. However, continuously monitoring respiratory rates outside clinical settings remains challenging due to the obtrusive nature and sensitivity to body motions in existing monitoring approaches. In this study, we propose a single-point-of-contact wearable device that leverages off-the-shelf, consumer-grade ultra-wideband radar to monitor respiratory rate as part of a chest strap. Our signal processing pipeline reliably extracts the wearer's respiratory signal from windowed complex channel impulse responses. In a controlled experiment, twelve participants performed various activities to evaluate the system's accuracy under motion while capturing ground-truth recordings through a spirometer. Our method extracted respiratory rates with less than 1 breath per minute deviation in 71% of all measurements, averaging 1.11 breaths per minute across all sessions and participants. Our findings underscore the potential of consumer-grade ultra-wideband radar technology in body-worn devices for unobtrusive yet effective respiratory monitoring.
△ Less
Submitted 28 October, 2024;
originally announced November 2024.
-
Gradient-Based Geometry Learning for Fan-Beam CT Reconstruction
Authors:
Mareike Thies,
Fabian Wagner,
Noah Maul,
Lukas Folle,
Manuela Meier,
Maximilian Rohleder,
Linda-Sophie Schneider,
Laura Pfaff,
Mingxuan Gu,
Jonas Utz,
Felix Denzinger,
Michael Manhart,
Andreas Maier
Abstract:
Incorporating computed tomography (CT) reconstruction operators into differentiable pipelines has proven beneficial in many applications. Such approaches usually focus on the projection data and keep the acquisition geometry fixed. However, precise knowledge of the acquisition geometry is essential for high quality reconstruction results. In this paper, the differentiable formulation of fan-beam C…
▽ More
Incorporating computed tomography (CT) reconstruction operators into differentiable pipelines has proven beneficial in many applications. Such approaches usually focus on the projection data and keep the acquisition geometry fixed. However, precise knowledge of the acquisition geometry is essential for high quality reconstruction results. In this paper, the differentiable formulation of fan-beam CT reconstruction is extended to the acquisition geometry. This allows to propagate gradient information from a loss function on the reconstructed image into the geometry parameters. As a proof-of-concept experiment, this idea is applied to rigid motion compensation. The cost function is parameterized by a trained neural network which regresses an image quality metric from the motion affected reconstruction alone. Using the proposed method, we are the first to optimize such an autofocus-inspired algorithm based on analytical gradients. The algorithm achieves a reduction in MSE by 35.5 % and an improvement in SSIM by 12.6 % over the motion affected reconstruction. Next to motion compensation, we see further use cases of our differentiable method for scanner calibration or hybrid techniques employing deep models.
△ Less
Submitted 5 December, 2022;
originally announced December 2022.
-
Capturing Shape Information with Multi-Scale Topological Loss Terms for 3D Reconstruction
Authors:
Dominik J. E. Waibel,
Scott Atwell,
Matthias Meier,
Carsten Marr,
Bastian Rieck
Abstract:
Reconstructing 3D objects from 2D images is both challenging for our brains and machine learning algorithms. To support this spatial reasoning task, contextual information about the overall shape of an object is critical. However, such information is not captured by established loss terms (e.g. Dice loss). We propose to complement geometrical shape information by including multi-scale topological…
▽ More
Reconstructing 3D objects from 2D images is both challenging for our brains and machine learning algorithms. To support this spatial reasoning task, contextual information about the overall shape of an object is critical. However, such information is not captured by established loss terms (e.g. Dice loss). We propose to complement geometrical shape information by including multi-scale topological features, such as connected components, cycles, and voids, in the reconstruction loss. Our method uses cubical complexes to calculate topological features of 3D volume data and employs an optimal transport distance to guide the reconstruction process. This topology-aware loss is fully differentiable, computationally efficient, and can be added to any neural network. We demonstrate the utility of our loss by incorporating it into SHAPR, a model for predicting the 3D cell shape of individual cells based on 2D microscopy images. Using a hybrid loss that leverages both geometrical and topological information of single objects to assess their shape, we find that topological information substantially improves the quality of reconstructions, thus highlighting its ability to extract more relevant features from image datasets.
△ Less
Submitted 16 September, 2022; v1 submitted 3 March, 2022;
originally announced March 2022.