-
Structurally Consistent MRI Colorization using Cross-modal Fusion Learning
Authors:
Mayuri Mathur,
Anav Chaudhary,
Saurabh Kumar Gupta,
Ojaswa Sharma
Abstract:
Medical image colorization can greatly enhance the interpretability of the underlying imaging modality and provide insights into human anatomy. The objective of medical image colorization is to transfer a diverse spectrum of colors distributed across human anatomy from Cryosection data to source MRI data while retaining the structures of the MRI. To achieve this, we propose a novel architecture fo…
▽ More
Medical image colorization can greatly enhance the interpretability of the underlying imaging modality and provide insights into human anatomy. The objective of medical image colorization is to transfer a diverse spectrum of colors distributed across human anatomy from Cryosection data to source MRI data while retaining the structures of the MRI. To achieve this, we propose a novel architecture for structurally consistent color transfer to the source MRI data. Our architecture fuses segmentation semantics of Cryosection images for stable contextual colorization of various organs in MRI images. For colorization, we neither require precise registration between MRI and Cryosection images, nor segmentation of MRI images. Additionally, our architecture incorporates a feature compression-and-activation mechanism to capture organ-level global information and suppress noise, enabling the distinction of organ-specific data in MRI scans for more accurate and realistic organ-specific colorization. Our experiments demonstrate that our architecture surpasses the existing methods and yields better quantitative and qualitative results.
△ Less
Submitted 12 December, 2024;
originally announced December 2024.
-
Pipeline-Invariant Representation Learning for Neuroimaging
Authors:
Xinhui Li,
Alex Fedorov,
Mrinal Mathur,
Anees Abrol,
Gregory Kiar,
Sergey Plis,
Vince Calhoun
Abstract:
Deep learning has been widely applied in neuroimaging, including predicting brain-phenotype relationships from magnetic resonance imaging (MRI) volumes. MRI data usually requires extensive preprocessing prior to modeling, but variation introduced by different MRI preprocessing pipelines may lead to different scientific findings, even when using the identical data. Motivated by the data-centric per…
▽ More
Deep learning has been widely applied in neuroimaging, including predicting brain-phenotype relationships from magnetic resonance imaging (MRI) volumes. MRI data usually requires extensive preprocessing prior to modeling, but variation introduced by different MRI preprocessing pipelines may lead to different scientific findings, even when using the identical data. Motivated by the data-centric perspective, we first evaluate how preprocessing pipeline selection can impact the downstream performance of a supervised learning model. We next propose two pipeline-invariant representation learning methodologies, MPSL and PXL, to improve robustness in classification performance and to capture similar neural network representations. Using 2000 human subjects from the UK Biobank dataset, we demonstrate that proposed models present unique and shared advantages, in particular that MPSL can be used to improve out-of-sample generalization to new pipelines, while PXL can be used to improve within-sample prediction performance. Both MPSL and PXL can learn more similar between-pipeline representations. These results suggest that our proposed models can be applied to mitigate pipeline-related biases, and to improve prediction robustness in brain-phenotype modeling.
△ Less
Submitted 15 October, 2023; v1 submitted 26 August, 2022;
originally announced August 2022.
-
Open and free EEG datasets for epilepsy diagnosis
Authors:
Palak Handa,
Monika Mathur,
Nidhi Goel
Abstract:
The Epilepsies are a common, chronic neurological disorder affecting more than 50 million individuals across the globe. It is characterized by unprovoked, recurring (similar or different type) seizures which are commonly diagnosed through clinical EEGs. Good-quality, open-access and free EEG data can act as a catalyst for on-going state-of-the-art (SOTA) research works for detection, prediction an…
▽ More
The Epilepsies are a common, chronic neurological disorder affecting more than 50 million individuals across the globe. It is characterized by unprovoked, recurring (similar or different type) seizures which are commonly diagnosed through clinical EEGs. Good-quality, open-access and free EEG data can act as a catalyst for on-going state-of-the-art (SOTA) research works for detection, prediction and management of epilepsy and seizures. They can also aid in improving the quality of life (QOL) of these diseased individuals and contribute research in healthcare multimedia, data analytics and Artificial Intelligence (AI) in personalized medicine. This paper presents widely used, available, open and free EEG datasets available for epilepsy and seizure diagnosis. A brief comparison and discussion of open and private datasets has also been done. Such datasets will help in development and evaluation of automatic computer-aided system in healthcare.
△ Less
Submitted 2 August, 2021;
originally announced August 2021.
-
Parametric Analysis of Smartphone Camera for a Low Cost Particle Image Velocimetry System
Authors:
Vishesh Kashyap,
Sushrut Kumar,
Nehal Amit Jajal,
Mrudang Mathur,
Raj Kumar Singh
Abstract:
This study focuses on assessing smartphone camera characteristics for developing an economic smartphone-based Particle Image Velocimetry (PIV) system. In the investigation, flow around a cylinder was visualized using two commercially-available smartphones (OnePlus 5T and iPhone X) cameras and low-intensity laser diodes. Hydrogen bubbles generated from electrolysis (termed Bubble Image Velocimetry)…
▽ More
This study focuses on assessing smartphone camera characteristics for developing an economic smartphone-based Particle Image Velocimetry (PIV) system. In the investigation, flow around a cylinder was visualized using two commercially-available smartphones (OnePlus 5T and iPhone X) cameras and low-intensity laser diodes. Hydrogen bubbles generated from electrolysis (termed Bubble Image Velocimetry) of aluminum electrodes were used as seeding medium. OpenPIV, an open-source toolbox, was used for processing captured images and obtaining the flow fields. A parametric analysis of the two smartphones was conducted across varying camera characteristics such as ISO, exposure compensation and frame rate. The results obtained through experimentation were compared with the results of a validated computational fluid dynamics (CFD) study with the same flow conditions and were found to be in good agreement, with deviation ranging from 1% to 3.5% for iPhone X and 1% to 7% for OnePlus 5T. It was observed that a higher frame rate results in greater accuracy of the measurement. Further, an exposure compensation of -1 EV and an ISO of 400 was found to produce results with the least error as compared to CFD values.
△ Less
Submitted 26 September, 2020; v1 submitted 30 January, 2020;
originally announced February 2020.
-
A Novel RF Energy Harvesting Module Integrated on a Single Substrate
Authors:
Monika Mathur,
Ankit Agarawal,
Ghanshyam Singh,
S. K. Bhatnagar
Abstract:
This paper presents the RF energy harvesting module (RECTENNA). The working range of this module includes multiple bands i.e. GSM, ISM, WLAN, and UWB band. To enhance the capturing RF power capability an array arrangement of coplanar monopole antenna has been proposed. Wilkinson power combiner has also been implemented to combine the powers of this antenna array. The RF DC converter circuit having…
▽ More
This paper presents the RF energy harvesting module (RECTENNA). The working range of this module includes multiple bands i.e. GSM, ISM, WLAN, and UWB band. To enhance the capturing RF power capability an array arrangement of coplanar monopole antenna has been proposed. Wilkinson power combiner has also been implemented to combine the powers of this antenna array. The RF DC converter circuit having seven stages has also been integrated with this structure. This module produces the DC voltage of 1.8V with respect to +40dB RF input. It is the unique module because it has no need of port connectors. The impedance matching of antenna and converter has been fulfilled by incorporating the passive component at the combiners branch. The value of this passive component is kept equal to the existing value of impedance at input port of converter circuit.
△ Less
Submitted 9 November, 2017;
originally announced December 2017.