-
Contrast-Free Ultrasound Microvascular Imaging via Radiality and Similarity Weighting
Authors:
Jingyi Yin,
Jingke Zhang,
Lijie Huang,
U-Wai Lok,
Ryan M DeRuiter,
Kaipeng Ji,
Yanzhe Zhao,
Kate M. Knoll,
Kendra E. Petersen,
Tao Wu,
Xiang-yang Zhu,
James D Krier,
Kathryn A. Robinson,
Lilach O Lerman,
Andrew J. Bentall,
Shigao Chen,
Chengwu Huang
Abstract:
Microvascular imaging has advanced significantly with ultrafast data acquisition and improved clutter filtering, enhancing the sensitivity of power Doppler imaging to small vessels. However, the image quality remains limited by spatial resolution and elevated background noise, both of which impede visualization and accurate quantification. To address these limitations, this study proposes a high-r…
▽ More
Microvascular imaging has advanced significantly with ultrafast data acquisition and improved clutter filtering, enhancing the sensitivity of power Doppler imaging to small vessels. However, the image quality remains limited by spatial resolution and elevated background noise, both of which impede visualization and accurate quantification. To address these limitations, this study proposes a high-resolution cross-correlation Power Doppler (HR-XPD) method that integrates spatial radiality weighting with Doppler signal coherence analysis, thereby enhancing spatial resolution while suppressing artifacts and background noise. Quantitative evaluations in simulation and in vivo experiments on healthy human liver, transplanted human kidney, and pig kidney demonstrated that HR-XPD significantly improves microvascular resolvability and contrast compared to conventional PD. In vivo results showed up to a 2 to 3-fold enhancement in spatial resolution and an increase in contrast by up to 20 dB. High-resolution vascular details were clearly depicted within a short acquisition time of only 0.3 s-1.2 s without the use of contrast agents. These findings indicate that HR-XPD provides an effective, contrast-free, and high-resolution microvascular imaging approach with broad applicability in both preclinical and clinical research.
△ Less
Submitted 8 September, 2025;
originally announced September 2025.
-
Self-supervised Deep Learning for Denoising in Ultrasound Microvascular Imaging
Authors:
Lijie Huang,
Jingyi Yin,
Jingke Zhang,
U-Wai Lok,
Ryan M. DeRuiter,
Jieyang Jin,
Kate M. Knoll,
Kendra E. Petersen,
James D. Krier,
Xiang-yang Zhu,
Gina K. Hesley,
Kathryn A. Robinson,
Andrew J. Bentall,
Thomas D. Atwell,
Andrew D. Rule,
Lilach O. Lerman,
Shigao Chen,
Chengwu Huang
Abstract:
Ultrasound microvascular imaging (UMI) is often hindered by low signal-to-noise ratio (SNR), especially in contrast-free or deep tissue scenarios, which impairs subsequent vascular quantification and reliable disease diagnosis. To address this challenge, we propose Half-Angle-to-Half-Angle (HA2HA), a self-supervised denoising framework specifically designed for UMI. HA2HA constructs training pairs…
▽ More
Ultrasound microvascular imaging (UMI) is often hindered by low signal-to-noise ratio (SNR), especially in contrast-free or deep tissue scenarios, which impairs subsequent vascular quantification and reliable disease diagnosis. To address this challenge, we propose Half-Angle-to-Half-Angle (HA2HA), a self-supervised denoising framework specifically designed for UMI. HA2HA constructs training pairs from complementary angular subsets of beamformed radio-frequency (RF) blood flow data, across which vascular signals remain consistent while noise varies. HA2HA was trained using in-vivo contrast-free pig kidney data and validated across diverse datasets, including contrast-free and contrast-enhanced data from pig kidneys, as well as human liver and kidney. An improvement exceeding 15 dB in both contrast-to-noise ratio (CNR) and SNR was observed, indicating a substantial enhancement in image quality. In addition to power Doppler imaging, denoising directly in the RF domain is also beneficial for other downstream processing such as color Doppler imaging (CDI). CDI results of human liver derived from the HA2HA-denoised signals exhibited improved microvascular flow visualization, with a suppressed noisy background. HA2HA offers a label-free, generalizable, and clinically applicable solution for robust vascular imaging in both contrast-free and contrast-enhanced UMI.
△ Less
Submitted 7 July, 2025;
originally announced July 2025.
-
Optimizing In Vivo Data Acquisition for Robust Clinical Microvascular Imaging Using Ultrasound Localization Microscopy
Authors:
Chengwu Huang,
U-Wai Lok,
Jingke Zhang,
Xiang Yang Zhu,
James D. Krier,
Amy Stern,
Kate M. Knoll,
Kendra E. Petersen,
Kathryn A. Robinson,
Gina K. Hesley,
Andrew J. Bentall,
Thomas D. Atwell,
Andrew D. Rule,
Lilach O. Lerman,
Shigao Chen
Abstract:
Ultrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of…
▽ More
Ultrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of variations underscore the need to optimize MB dosage, data acquisition timing, and imaging settings in order to standardize and optimize ULM of microvasculature. This pilot study investigated temporal changes in MB signals during bolus injections in both pig and human models to optimize data acquisition for clinical ULM. Quantitative indices were developed to evaluate MB signal quality, guiding selection of acquisition timing that balances the MB localization quality and adequate MB counts. The effects of transmitted voltage and dosage were also explored. In the pig model, a relatively short window (approximately 10 seconds) for optimal acquisition was identified during the rapid wash-out phase, highlighting the need for real-time MB signal monitoring during data acquisition. The slower wash-out phase in humans allowed for a more flexible imaging window of 1-2 minutes, while trade-offs were observed between localization quality and MB density (or acquisition length) at different wash-out phase timings. Guided by these findings, robust ULM imaging was achieved in both pig and human kidneys using a short period of data acquisition, demonstrating its feasibility in clinical practice. This study provides insights into optimizing data acquisition for consistent and reproducible ULM, paving the way for its standardization and broader clinical applications.
△ Less
Submitted 23 December, 2024;
originally announced December 2024.
-
Super-Resolution Ultrasound Localization Microscopy Based on a High Frame-rate Clinical Ultrasound Scanner: An In-human Feasibility Study
Authors:
Chengwu Huang,
Wei Zhang,
Ping Gong,
U-Wai Lok,
Shanshan Tang,
Tinghui Yin,
Xirui Zhang,
Lei Zhu,
Maodong Sang,
Pengfei Song,
Rongqin Zheng,
Shigao Chen
Abstract:
Non-invasive detection of microvascular alterations in deep tissues in vivo provides critical information for clinical diagnosis and evaluation of a broad-spectrum of pathologies. Recently, the emergence of super-resolution ultrasound localization microscopy (ULM) offers new possibilities for clinical imaging of microvasculature at capillary level. Currently, the clinical utility of ULM on clinica…
▽ More
Non-invasive detection of microvascular alterations in deep tissues in vivo provides critical information for clinical diagnosis and evaluation of a broad-spectrum of pathologies. Recently, the emergence of super-resolution ultrasound localization microscopy (ULM) offers new possibilities for clinical imaging of microvasculature at capillary level. Currently, the clinical utility of ULM on clinical ultrasound scanners is hindered by the technical limitations, such as long data acquisition time, and compromised tracking performance associated with low imaging frame-rate. Here we present an in-human ULM on a high frame-rate (HFR) clinical ultrasound scanner to achieve super-resolution microvessel imaging using a short acquisition time (<10s). Ultrasound MB data were acquired from different human tissues, (liver, kidney, pancreatic, and breast tumor) using an HFR clinical scanner. By leveraging the HFR and advanced processing techniques including sub-pixel motion registration, MB signal separation, and Kalman filter-based tracking, MBs can be robustly localized and tracked for successful ULM under the circumstances of relatively high MB concentration and limited data acquisition time in humans. Subtle morphological and hemodynamic information were demonstrated on data acquired with single breath-hold and free-hand scanning. Compared with contrast-enhanced power Doppler generated based on the same MB dataset, ULM showed a 5.7-fold resolution improvement in a vessel, and provided a wide-range flow speed measurement that is Doppler angle-independent. This study demonstrated the feasibility of ultrafast in-human ULM in various human tissues based on a clinical scanner that supports HFR imaging, and showed a great potential for the implementation of super-resolution ultrasound microvessel imaging in a myriad of clinical applications involving microvascular abnormalities and pathologies.
△ Less
Submitted 28 September, 2020;
originally announced September 2020.