-
Read Like a Radiologist: Efficient Vision-Language Model for 3D Medical Imaging Interpretation
Authors:
Changsun Lee,
Sangjoon Park,
Cheong-Il Shin,
Woo Hee Choi,
Hyun Jeong Park,
Jeong Eun Lee,
Jong Chul Ye
Abstract:
Recent medical vision-language models (VLMs) have shown promise in 2D medical image interpretation. However extending them to 3D medical imaging has been challenging due to computational complexities and data scarcity. Although a few recent VLMs specified for 3D medical imaging have emerged, all are limited to learning volumetric representation of a 3D medical image as a set of sub-volumetric feat…
▽ More
Recent medical vision-language models (VLMs) have shown promise in 2D medical image interpretation. However extending them to 3D medical imaging has been challenging due to computational complexities and data scarcity. Although a few recent VLMs specified for 3D medical imaging have emerged, all are limited to learning volumetric representation of a 3D medical image as a set of sub-volumetric features. Such process introduces overly correlated representations along the z-axis that neglect slice-specific clinical details, particularly for 3D medical images where adjacent slices have low redundancy. To address this limitation, we introduce MS-VLM that mimic radiologists' workflow in 3D medical image interpretation. Specifically, radiologists analyze 3D medical images by examining individual slices sequentially and synthesizing information across slices and views. Likewise, MS-VLM leverages self-supervised 2D transformer encoders to learn a volumetric representation that capture inter-slice dependencies from a sequence of slice-specific features. Unbound by sub-volumetric patchification, MS-VLM is capable of obtaining useful volumetric representations from 3D medical images with any slice length and from multiple images acquired from different planes and phases. We evaluate MS-VLM on publicly available chest CT dataset CT-RATE and in-house rectal MRI dataset. In both scenarios, MS-VLM surpasses existing methods in radiology report generation, producing more coherent and clinically relevant reports. These findings highlight the potential of MS-VLM to advance 3D medical image interpretation and improve the robustness of medical VLMs.
△ Less
Submitted 18 December, 2024;
originally announced December 2024.
-
Improving Medical Speech-to-Text Accuracy with Vision-Language Pre-training Model
Authors:
Jaeyoung Huh,
Sangjoon Park,
Jeong Eun Lee,
Jong Chul Ye
Abstract:
Automatic Speech Recognition (ASR) is a technology that converts spoken words into text, facilitating interaction between humans and machines. One of the most common applications of ASR is Speech-To-Text (STT) technology, which simplifies user workflows by transcribing spoken words into text. In the medical field, STT has the potential to significantly reduce the workload of clinicians who rely on…
▽ More
Automatic Speech Recognition (ASR) is a technology that converts spoken words into text, facilitating interaction between humans and machines. One of the most common applications of ASR is Speech-To-Text (STT) technology, which simplifies user workflows by transcribing spoken words into text. In the medical field, STT has the potential to significantly reduce the workload of clinicians who rely on typists to transcribe their voice recordings. However, developing an STT model for the medical domain is challenging due to the lack of sufficient speech and text datasets. To address this issue, we propose a medical-domain text correction method that modifies the output text of a general STT system using the Vision Language Pre-training (VLP) method. VLP combines textual and visual information to correct text based on image knowledge. Our extensive experiments demonstrate that the proposed method offers quantitatively and clinically significant improvements in STT performance in the medical field. We further show that multi-modal understanding of image and text information outperforms single-modal understanding using only text information.
△ Less
Submitted 27 February, 2023;
originally announced March 2023.
-
Annealed Score-Based Diffusion Model for MR Motion Artifact Reduction
Authors:
Gyutaek Oh,
Jeong Eun Lee,
Jong Chul Ye
Abstract:
Motion artifact reduction is one of the important research topics in MR imaging, as the motion artifact degrades image quality and makes diagnosis difficult. Recently, many deep learning approaches have been studied for motion artifact reduction. Unfortunately, most existing models are trained in a supervised manner, requiring paired motion-corrupted and motion-free images, or are based on a stric…
▽ More
Motion artifact reduction is one of the important research topics in MR imaging, as the motion artifact degrades image quality and makes diagnosis difficult. Recently, many deep learning approaches have been studied for motion artifact reduction. Unfortunately, most existing models are trained in a supervised manner, requiring paired motion-corrupted and motion-free images, or are based on a strict motion-corruption model, which limits their use for real-world situations. To address this issue, here we present an annealed score-based diffusion model for MRI motion artifact reduction. Specifically, we train a score-based model using only motion-free images, and then motion artifacts are removed by applying forward and reverse diffusion processes repeatedly to gradually impose a low-frequency data consistency. Experimental results verify that the proposed method successfully reduces both simulated and in vivo motion artifacts, outperforming the state-of-the-art deep learning methods.
△ Less
Submitted 8 January, 2023;
originally announced January 2023.
-
Self-supervised Multi-modal Training from Uncurated Image and Reports Enables Zero-shot Oversight Artificial Intelligence in Radiology
Authors:
Sangjoon Park,
Eun Sun Lee,
Kyung Sook Shin,
Jeong Eun Lee,
Jong Chul Ye
Abstract:
Oversight AI is an emerging concept in radiology where the AI forms a symbiosis with radiologists by continuously supporting radiologists in their decision-making. Recent advances in vision-language models sheds a light on the long-standing problems of the oversight AI by the understanding both visual and textual concepts and their semantic correspondences. However, there have been limited success…
▽ More
Oversight AI is an emerging concept in radiology where the AI forms a symbiosis with radiologists by continuously supporting radiologists in their decision-making. Recent advances in vision-language models sheds a light on the long-standing problems of the oversight AI by the understanding both visual and textual concepts and their semantic correspondences. However, there have been limited successes in the application of vision-language models in the medical domain, as the current vision-language models and learning strategies for photographic images and captions call for the web-scale data corpus of image and text pairs which was not often feasible in the medical domain. To address this, here we present a model dubbed Medical Cross-attention Vision-Language model (Medical X-VL), leveraging the key components to be tailored for the medical domain. Our medical X-VL model is based on the following components: self-supervised uni-modal models in medical domain and fusion encoder to bridge them, momentum distillation, sentence-wise contrastive learning for medical reports, and the sentence similarity-adjusted hard negative mining. We experimentally demonstrated that our model enables various zero-shot tasks for oversight AI, ranging from the zero-shot classification to zero-shot error correction. Our model outperformed the current state-of-the-art models in two different medical image database, suggesting the novel clinical usage of our oversight AI model for monitoring human errors. Our method was especially successful in the data-limited setting, which is frequently encountered in the clinics, suggesting the potential widespread applicability in medical domain.
△ Less
Submitted 12 April, 2023; v1 submitted 10 August, 2022;
originally announced August 2022.
-
Unsupervised MR Motion Artifact Deep Learning using Outlier-Rejecting Bootstrap Aggregation
Authors:
Gyutaek Oh,
Jeong Eun Lee,
Jong Chul Ye
Abstract:
Recently, deep learning approaches for MR motion artifact correction have been extensively studied. Although these approaches have shown high performance and reduced computational complexity compared to classical methods, most of them require supervised training using paired artifact-free and artifact-corrupted images, which may prohibit its use in many important clinical applications. For example…
▽ More
Recently, deep learning approaches for MR motion artifact correction have been extensively studied. Although these approaches have shown high performance and reduced computational complexity compared to classical methods, most of them require supervised training using paired artifact-free and artifact-corrupted images, which may prohibit its use in many important clinical applications. For example, transient severe motion (TSM) due to acute transient dyspnea in Gd-EOB-DTPA-enhanced MR is difficult to control and model for paired data generation. To address this issue, here we propose a novel unsupervised deep learning scheme through outlier-rejecting bootstrap subsampling and aggregation. This is inspired by the observation that motions usually cause sparse k-space outliers in the phase encoding direction, so k-space subsampling along the phase encoding direction can remove some outliers and the aggregation step can further improve the results from the reconstruction network. Our method does not require any paired data because the training step only requires artifact-free images. Furthermore, to address the smoothing from potential bias to the artifact-free images, the network is trained in an unsupervised manner using optimal transport driven cycleGAN. We verify that our method can be applied for artifact correction from simulated motion as well as real motion from TSM successfully, outperforming existing state-of-the-art deep learning methods.
△ Less
Submitted 12 November, 2020;
originally announced November 2020.