Synthetic Generation and Latent Projection Denoising of Rim Lesions in Multiple Sclerosis
Authors:
Alexandra G. Roberts,
Ha M. Luu,
Mert Şişman,
Alexey V. Dimov,
Ceren Tozlu,
Ilhami Kovanlikaya,
Susan A. Gauthier,
Thanh D. Nguyen,
Yi Wang
Abstract:
Quantitative susceptibility maps from magnetic resonance images can provide both prognostic and diagnostic information in multiple sclerosis, a neurodegenerative disease characterized by the formation of lesions in white matter brain tissue. In particular, susceptibility maps provide adequate contrast to distinguish between "rim" lesions, surrounded by deposited paramagnetic iron, and "non-rim" le…
▽ More
Quantitative susceptibility maps from magnetic resonance images can provide both prognostic and diagnostic information in multiple sclerosis, a neurodegenerative disease characterized by the formation of lesions in white matter brain tissue. In particular, susceptibility maps provide adequate contrast to distinguish between "rim" lesions, surrounded by deposited paramagnetic iron, and "non-rim" lesion types. These paramagnetic rim lesions (PRLs) are an emerging biomarker in multiple sclerosis. Much effort has been devoted to both detection and segmentation of such lesions to monitor longitudinal change. As paramagnetic rim lesions are rare, addressing this problem requires confronting the class imbalance between rim and non-rim lesions. We produce synthetic quantitative susceptibility maps of paramagnetic rim lesions and show that inclusion of such synthetic data improves classifier performance and provide a multi-channel extension to generate accompanying contrasts and probabilistic segmentation maps. We exploit the projection capability of our trained generative network to demonstrate a novel denoising approach that allows us to train on ambiguous rim cases and substantially increase the minority class. We show that both synthetic lesion synthesis and our proposed rim lesion label denoising method best approximate the unseen rim lesion distribution and improve detection in a clinically interpretable manner. We release our code and generated data at https://github.com/agr78/PRLx-GAN upon publication.
△ Less
Submitted 29 May, 2025;
originally announced May 2025.
-
QSM-RimDS: A detection and segmentation tool for paramagnetic rim lesions in multiple sclerosis
Authors:
Ha Luu,
Mert Sisman,
Ilhami Kovanlikaya,
Tam Vu,
Pascal Spincemaille,
Yi Wang,
Francesca Bagnato,
Susan Gauthier,
Thanh Nguyen
Abstract:
Paramagnetic rim lesions (PRLs) are an emerging biomarker in multiple sclerosis (MS). Manual identification and rim segmentation of PRLs on quantitative susceptibility mapping (QSM) images are time-consuming. Deep learning-based QSM-RimNet can provide automated PRL detection, but this method does not provide rim segmentation for microglial density quantification and requires precise QSM lesion mas…
▽ More
Paramagnetic rim lesions (PRLs) are an emerging biomarker in multiple sclerosis (MS). Manual identification and rim segmentation of PRLs on quantitative susceptibility mapping (QSM) images are time-consuming. Deep learning-based QSM-RimNet can provide automated PRL detection, but this method does not provide rim segmentation for microglial density quantification and requires precise QSM lesion masks. The purpose of this study is to develop a U-Net-based QSM-RimDS method for joint PRL detection and rim segmentation using readily available T2-weighted (T2W) fluid-attenuated inversion recovery (FLAIR) lesion masks. Two expert readers performed PRL classification and rim segmentation as the reference. Dice similarity coefficient (DSC) was used to assess the agreement between rim segmentation obtained by QSM-RimDS and the manual expert segmentation. The PRL detection performances of QSM-RimDS and QSM-RimNet were evaluated using receiver operating characteristic (ROC) and precision-recall (PR) plots in a five-fold cross validation. A total of 260 PRLs (3.3\%) and 7720 non-PRLs (96.7\%) were identified by the readers. Compared to the expert rim segmentation, QSM-RimDS provided a mean DSC of 0.57 \pm 0.02 with moderate to high agreement (DSC \leq 0.5) in 73.8pm 5.7\% of PRLs over five folds. QSM-RimDS produced better and more consistent detection performance with a mean area under curve (AUC) of 0.754 \pm 0.037 vs. 0.514 \pm 0.121 by QSM-RimNet (46.7\% improvement) on PR plots, and 0.956 \pm 0.034 vs. 0.908 \pm 0.073 (5.3\% improvement) on ROC plots. In conclusion, QSM-RimDS improves PRL detection accuracy compared to QSM-RimNet and unlike QSM-RimNet can provide reasonably accurate rim segmentation.
△ Less
Submitted 22 March, 2025; v1 submitted 13 December, 2024;
originally announced December 2024.
-
Maximum Spherical Mean Value (mSMV) Filtering for Whole Brain Quantitative Susceptibility Mapping
Authors:
Alexandra G. Roberts,
Dominick J. Romano,
Mert Şişman,
Alexey V. Dimov,
Pascal Spincemaille,
Thanh D. Nguyen,
Ilhami Kovanlikaya,
Susan A. Gauthier,
Yi Wang
Abstract:
To develop a tissue field filtering algorithm, called maximum Spherical Mean Value (mSMV), for reducing shadow artifacts in quantitative susceptibility mapping (QSM) of the brain without requiring brain tissue erosion. Residual background field is a major source of shadow artifacts in QSM. The mSMV algorithm filters large field values near the border, where the maximum value of the harmonic backgr…
▽ More
To develop a tissue field filtering algorithm, called maximum Spherical Mean Value (mSMV), for reducing shadow artifacts in quantitative susceptibility mapping (QSM) of the brain without requiring brain tissue erosion. Residual background field is a major source of shadow artifacts in QSM. The mSMV algorithm filters large field values near the border, where the maximum value of the harmonic background field is located. The effectiveness of mSMV for artifact removal was evaluated by comparing with existing QSM algorithms in numerical brain simulation as well as using in vivo human data acquired from 11 healthy volunteers and 93 patients. Numerical simulation showed that mSMV reduces shadow artifacts and improves QSM accuracy. Better shadow reduction, as demonstrated by lower QSM variation in the gray matter and higher QSM image quality score, was also observed in healthy subjects and in patients with hemorrhages, stroke and multiple sclerosis. The mSMV algorithm allows QSM maps that are substantially equivalent to those obtained using SMV-filtered dipole inversion without eroding the volume of interest.
△ Less
Submitted 29 May, 2025; v1 submitted 22 April, 2023;
originally announced April 2023.
-
LARO: Learned Acquisition and Reconstruction Optimization to accelerate Quantitative Susceptibility Mapping
Authors:
Jinwei Zhang,
Pascal Spincemaille,
Hang Zhang,
Thanh D. Nguyen,
Chao Li,
Jiahao Li,
Ilhami Kovanlikaya,
Mert R. Sabuncu,
Yi Wang
Abstract:
Quantitative susceptibility mapping (QSM) involves acquisition and reconstruction of a series of images at multi-echo time points to estimate tissue field, which prolongs scan time and requires specific reconstruction technique. In this paper, we present our new framework, called Learned Acquisition and Reconstruction Optimization (LARO), which aims to accelerate the multi-echo gradient echo (mGRE…
▽ More
Quantitative susceptibility mapping (QSM) involves acquisition and reconstruction of a series of images at multi-echo time points to estimate tissue field, which prolongs scan time and requires specific reconstruction technique. In this paper, we present our new framework, called Learned Acquisition and Reconstruction Optimization (LARO), which aims to accelerate the multi-echo gradient echo (mGRE) pulse sequence for QSM. Our approach involves optimizing a Cartesian multi-echo k-space sampling pattern with a deep reconstruction network. Next, this optimized sampling pattern was implemented in an mGRE sequence using Cartesian fan-beam k-space segmenting and ordering for prospective scans. Furthermore, we propose to insert a recurrent temporal feature fusion module into the reconstruction network to capture signal redundancies along echo time. Our ablation studies show that both the optimized sampling pattern and proposed reconstruction strategy help improve the quality of the multi-echo image reconstructions. Generalization experiments show that LARO is robust on the test data with new pathologies and different sequence parameters. Our code is available at https://github.com/Jinwei1209/LARO.git.
△ Less
Submitted 1 November, 2022;
originally announced November 2022.