-
Handling Label Uncertainty on the Example of Automatic Detection of Shepherd's Crook RCA in Coronary CT Angiography
Authors:
Felix Denzinger,
Michael Wels,
Oliver Taubmann,
Florian Kordon,
Fabian Wagner,
Stephanie Mehltretter,
Mehmet A. Gülsün,
Max Schöbinger,
Florian André,
Sebastian Buss,
Johannes Görich,
Michael Sühling,
Andreas Maier
Abstract:
Coronary artery disease (CAD) is often treated minimally invasively with a catheter being inserted into the diseased coronary vessel. If a patient exhibits a Shepherd's Crook (SC) Right Coronary Artery (RCA) - an anatomical norm variant of the coronary vasculature - the complexity of this procedure is increased. Automated reporting of this variant from coronary CT angiography screening would ease…
▽ More
Coronary artery disease (CAD) is often treated minimally invasively with a catheter being inserted into the diseased coronary vessel. If a patient exhibits a Shepherd's Crook (SC) Right Coronary Artery (RCA) - an anatomical norm variant of the coronary vasculature - the complexity of this procedure is increased. Automated reporting of this variant from coronary CT angiography screening would ease prior risk assessment. We propose a 1D convolutional neural network which leverages a sequence of residual dilated convolutions to automatically determine this norm variant from a prior extracted vessel centerline. As the SC RCA is not clearly defined with respect to concrete measurements, labeling also includes qualitative aspects. Therefore, 4.23% samples in our dataset of 519 RCA centerlines were labeled as unsure SC RCAs, with 5.97% being labeled as sure SC RCAs. We explore measures to handle this label uncertainty, namely global/model-wise random assignment, exclusion, and soft label assignment. Furthermore, we evaluate how this uncertainty can be leveraged for the determination of a rejection class. With our best configuration, we reach an area under the receiver operating characteristic curve (AUC) of 0.938 on confident labels. Moreover, we observe an increase of up to 0.020 AUC when rejecting 10% of the data and leveraging the labeling uncertainty information in the exclusion process.
△ Less
Submitted 22 May, 2023;
originally announced June 2023.
-
Segmentation of the Carotid Lumen and Vessel Wall using Deep Learning and Location Priors
Authors:
Florian Thamm,
Felix Denzinger,
Leonhard Rist,
Celia Martin Vicario,
Florian Kordon,
Andreas Maier
Abstract:
In this report we want to present our method and results for the Carotid Artery Vessel Wall Segmentation Challenge. We propose an image-based pipeline utilizing the U-Net architecture and location priors to solve the segmentation problem at hand.
In this report we want to present our method and results for the Carotid Artery Vessel Wall Segmentation Challenge. We propose an image-based pipeline utilizing the U-Net architecture and location priors to solve the segmentation problem at hand.
△ Less
Submitted 14 May, 2022; v1 submitted 17 January, 2022;
originally announced January 2022.
-
View-Consistent Metal Segmentation in the Projection Domain for Metal Artifact Reduction in CBCT -- An Investigation of Potential Improvement
Authors:
Tristan M. Gottschalk,
Andreas Maier,
Florian Kordon,
Björn W. Kreher
Abstract:
The positive outcome of a trauma intervention depends on an intraoperative evaluation of inserted metallic implants. Due to occurring metal artifacts, the quality of this evaluation heavily depends on the performance of so-called Metal Artifact Reduction methods (MAR). The majority of these MAR methods require prior segmentation of the inserted metal objects. Therefore, typically a rather simple t…
▽ More
The positive outcome of a trauma intervention depends on an intraoperative evaluation of inserted metallic implants. Due to occurring metal artifacts, the quality of this evaluation heavily depends on the performance of so-called Metal Artifact Reduction methods (MAR). The majority of these MAR methods require prior segmentation of the inserted metal objects. Therefore, typically a rather simple thresholding-based segmentation method in the reconstructed 3D volume is applied, despite some major disadvantages. With this publication, the potential of shifting the segmentation task to a learning-based, view-consistent 2D projection-based method on the downstream MAR's outcome is investigated. For segmenting the present metal, a rather simple learning-based 2D projection-wise segmentation network that is trained using real data acquired during cadaver studies, is examined. To overcome the disadvantages that come along with a 2D projection-wise segmentation, a Consistency Filter is proposed. The influence of the shifted segmentation domain is investigated by comparing the results of the standard fsMAR with a modified fsMAR version using the new segmentation masks. With a quantitative and qualitative evaluation on real cadaver data, the investigated approach showed an increased MAR performance and a high insensitivity against metal artifacts. For cases with metal outside the reconstruction's FoV or cases with vanishing metal, a significant reduction in artifacts could be shown. Thus, increases of up to roughly 3 dB w.r.t. the mean PSNR metric over all slices and up to 9 dB for single slices were achieved. The shown results reveal a beneficial influence of the shift to a 2D-based segmentation method on real data for downstream use with a MAR method, like the fsMAR.
△ Less
Submitted 3 December, 2021;
originally announced December 2021.
-
Automatic Plane Adjustment of Orthopedic Intra-operative Flat Panel Detector CT-Volumes
Authors:
Celia Martin Vicario,
Florian Kordon,
Felix Denzinger,
Jan Siad El Barbari,
Maxim Privalov,
Jochen Franke,
Sarina Thomas,
Lisa Kausch,
Andreas Maier,
Holger Kunze
Abstract:
Purpose
3D acquisitions are often acquired to assess the result in orthopedic trauma surgery. With a mobile C-Arm system, these acquisitions can be performed intra-operatively. That reduces the number of required revision surgeries. However, due to the operation room setup, the acquisitions typically cannot be performed such that the acquired volumes are aligned to the anatomical regions. Thus,…
▽ More
Purpose
3D acquisitions are often acquired to assess the result in orthopedic trauma surgery. With a mobile C-Arm system, these acquisitions can be performed intra-operatively. That reduces the number of required revision surgeries. However, due to the operation room setup, the acquisitions typically cannot be performed such that the acquired volumes are aligned to the anatomical regions. Thus, the multiplanar reconstructed (MPR) planes need to be adjusted manually during the review of the volume. In this paper, we present a detailed study of multi-task learning (MTL) regression networks to estimate the parameters of the MPR planes.
Approach
First, various mathematical descriptions for rotation, including Euler angle, quaternion, and matrix representation, are revised. Then, three different MTL network architectures based on the PoseNet are compared with a single task learning network.
Results
Using a matrix description rather than the Euler angle description, the accuracy of the regressed normals improves from $7.7^{\circ}$ to $7.3^{\circ}$ in the mean value for single anatomies. The multi-head approach improves the regression of the plane position from $7.4mm$ to $6.1mm$, while the orientation does not benefit from this approach.
Conclusions
The results show that a multi-head approach can lead to slightly better results than the individual tasks networks. The most important benefit of the MTL approach is that it is a single network for standard plane regression for all body regions with a reduced number of stored parameters.
△ Less
Submitted 15 September, 2021;
originally announced September 2021.
-
Learning-Based Patch-Wise Metal Segmentation with Consistency Check
Authors:
Tristan M. Gottschalk,
Andreas Maier,
Florian Kordon,
Björn W. Kreher
Abstract:
Metal implants that are inserted into the patient's body during trauma interventions cause heavy artifacts in 3D X-ray acquisitions. Metal Artifact Reduction (MAR) methods, whose first step is always a segmentation of the present metal objects, try to remove these artifacts. Thereby, the segmentation is a crucial task which has strong influence on the MAR's outcome. This study proposes and evaluat…
▽ More
Metal implants that are inserted into the patient's body during trauma interventions cause heavy artifacts in 3D X-ray acquisitions. Metal Artifact Reduction (MAR) methods, whose first step is always a segmentation of the present metal objects, try to remove these artifacts. Thereby, the segmentation is a crucial task which has strong influence on the MAR's outcome. This study proposes and evaluates a learning-based patch-wise segmentation network and a newly proposed Consistency Check as post-processing step. The combination of the learned segmentation and Consistency Check reaches a high segmentation performance with an average IoU score of 0.924 on the test set. Furthermore, the Consistency Check proves the ability to significantly reduce false positive segmentations whilst simultaneously ensuring consistent segmentations.
△ Less
Submitted 26 January, 2021;
originally announced January 2021.
-
Automatic Plane Adjustment of Orthopedic Intraoperative Flat Panel Detector CT-Volumes
Authors:
Celia Martín Vicario,
Florian Kordon,
Felix Denzinger,
Markus Weiten,
Sarina Thomas,
Lisa Kausch,
Jochen Franke,
Holger Keil,
Andreas Maier,
Holger Kunze
Abstract:
Flat panel computed tomography is used intraoperatively to assess the result of surgery. Due to workflow issues, the acquisition typically cannot be carried out in such a way that the axis aligned multiplanar reconstructions (MPR) of the volume match the anatomically aligned MPRs. This needs to be performed manually, adding additional effort during viewing the datasets. A PoseNet convolutional neu…
▽ More
Flat panel computed tomography is used intraoperatively to assess the result of surgery. Due to workflow issues, the acquisition typically cannot be carried out in such a way that the axis aligned multiplanar reconstructions (MPR) of the volume match the anatomically aligned MPRs. This needs to be performed manually, adding additional effort during viewing the datasets. A PoseNet convolutional neural network (CNN) is trained such that parameters of anatomically aligned MPR planes are regressed. Different mathematical approaches to describe plane rotation are compared, as well as a cost function is optimized to incorporate orientation constraints. The CNN is evaluated on two anatomical regions. For one of these regions, one plane is not orthogonal to the other two planes. The plane's normal can be estimated with a median accuracy of 5°, the in-plane rotation with an accuracy of 6°, and the position with an accuracy of 6 mm. Compared to state-of-the-art algorithms the labeling effort for this method is much lower as no segmentation is required. The computation time during inference is less than 0.05 s.
△ Less
Submitted 7 July, 2020;
originally announced July 2020.
-
Contour-based Bone Axis Detection for X-Ray Guided Surgery on the Knee
Authors:
Florian Kordon,
Andreas Maier,
Benedict Swartman,
Maxim Privalov,
Jan Siad El Barbari,
Holger Kunze
Abstract:
The anatomical axis of long bones is an important reference line for guiding fracture reduction and assisting in the correct placement of guide pins, screws, and implants in orthopedics and trauma surgery. This study investigates an automatic approach for detection of such axes on X-ray images based on the segmentation contour of the bone. For this purpose, we use the medically established two-lin…
▽ More
The anatomical axis of long bones is an important reference line for guiding fracture reduction and assisting in the correct placement of guide pins, screws, and implants in orthopedics and trauma surgery. This study investigates an automatic approach for detection of such axes on X-ray images based on the segmentation contour of the bone. For this purpose, we use the medically established two-line method and translate it into a learning-based approach. The proposed method is evaluated on 38 clinical test images of the femoral and tibial bone and achieves a median angulation error of 0.19° and 0.33° respectively. An inter-rater study with three trauma surgery experts confirms reliability of the method and recommends further clinical application.
△ Less
Submitted 5 July, 2020;
originally announced July 2020.
-
Multi-task Localization and Segmentation for X-ray Guided Planning in Knee Surgery
Authors:
Florian Kordon,
Peter Fischer,
Maxim Privalov,
Benedict Swartman,
Marc Schnetzke,
Jochen Franke,
Ruxandra Lasowski,
Andreas Maier,
Holger Kunze
Abstract:
X-ray based measurement and guidance are commonly used tools in orthopaedic surgery to facilitate a minimally invasive workflow. Typically, a surgical planning is first performed using knowledge of bone morphology and anatomical landmarks. Information about bone location then serves as a prior for registration during overlay of the planning on intra-operative X-ray images. Performing these steps m…
▽ More
X-ray based measurement and guidance are commonly used tools in orthopaedic surgery to facilitate a minimally invasive workflow. Typically, a surgical planning is first performed using knowledge of bone morphology and anatomical landmarks. Information about bone location then serves as a prior for registration during overlay of the planning on intra-operative X-ray images. Performing these steps manually however is prone to intra-rater/inter-rater variability and increases task complexity for the surgeon. To remedy these issues, we propose an automatic framework for planning and subsequent overlay. We evaluate it on the example of femoral drill site planning for medial patellofemoral ligament reconstruction surgery. A deep multi-task stacked hourglass network is trained on 149 conventional lateral X-ray images to jointly localize two femoral landmarks, to predict a region of interest for the posterior femoral cortex tangent line, and to perform semantic segmentation of the femur, patella, tibia, and fibula with adaptive task complexity weighting. On 38 clinical test images the framework achieves a median localization error of 1.50 mm for the femoral drill site and mean IOU scores of 0.99, 0.97, 0.98, and 0.96 for the femur, patella, tibia, and fibula respectively. The demonstrated approach consistently performs surgical planning at expert-level precision without the need for manual correction.
△ Less
Submitted 24 July, 2019;
originally announced July 2019.