Multiparametric quantification and visualization of liver fat using ultrasound
Authors:
Jihye Baek,
Ahmed El Kaffas,
Aya Kamaya,
Kenneth Hoyt,
Kevin J. Parker
Abstract:
Objectives- Several ultrasound measures have shown promise for assessment of steatosis compared to traditional B-scan, however clinicians may be required to integrate information across the parameters. Here, we propose an integrated multiparametric approach, enabling simple clinical assessment of key information from combined ultrasound parameters. Methods- We have measured 13 parameters related t…
▽ More
Objectives- Several ultrasound measures have shown promise for assessment of steatosis compared to traditional B-scan, however clinicians may be required to integrate information across the parameters. Here, we propose an integrated multiparametric approach, enabling simple clinical assessment of key information from combined ultrasound parameters. Methods- We have measured 13 parameters related to ultrasound and shear wave elastography. These were measured in 30 human subjects under a study of liver fat. The 13 individual measures are assessed for their predictive value using independent magnetic resonance imaging-derived proton density fat fraction (MRI-PDFF) measurements as a reference standard. In addition, a comprehensive and fine-grain analysis is made of all possible combinations of sub-sets of these parameters to determine if any subset can be efficiently combined to predict fat fraction. Results- We found that as few as four key parameters related to ultrasound propagation are sufficient to generate a linear multiparametric parameter with a correlation against MRI-PDFF values of greater than 0.93. This optimal combination was found to have a classification area under the curve (AUC) approaching 1.0 when applying a threshold for separating steatosis grade zero from higher classes. Furthermore, a strategy is developed for applying local estimates of fat content as a color overlay to produce a visual impression of the extent and distribution of fat within the liver. Conclusion- In principle, this approach can be applied to most clinical ultrasound systems to provide the clinician and patient with a rapid and inexpensive estimate of liver fat content.
△ Less
Submitted 2 April, 2024;
originally announced April 2024.
-
Clinical Evaluation of Real-Time Optical-Tracking Navigation and Live Time-Intensity Curves to Provide Feedback During Blinded 4D Contrast-Enhanced Ultrasound Imaging
Authors:
Ahmed El Kaffas,
Renhui Gong,
Samvardhini Sridharan,
Rosa Maria Silveira Sigrist,
Isabelle Durot,
Jürgen K. Willmann,
Dimitre Hristov
Abstract:
Current commercial matrix transducers for 3D DCE-US do not display side-by-side B-mode and contrast-mode images when capturing volumetric data, thus leaving the operator with no position feedback during lengthy acquisitions. The purpose of this study was to investigate the use of transducer tracking to provide positioning feedback and to re-align images to improve quantification. An interventional…
▽ More
Current commercial matrix transducers for 3D DCE-US do not display side-by-side B-mode and contrast-mode images when capturing volumetric data, thus leaving the operator with no position feedback during lengthy acquisitions. The purpose of this study was to investigate the use of transducer tracking to provide positioning feedback and to re-align images to improve quantification. An interventional tracking system was developed in house using an infrared camera and a 3D-printed tracking target attached to a X6-1 matrix transducer. The system displays a virtual probe on a separate screen and allows to capture a reference position to provide operator feedback when no B-mode image is available. To test this set-up, five experienced operators were asked to locate an image landmark within a volunteer liver in B-mode images using the X6-1 connected to an EPIQ7 system. Operators were then asked to maintain the transducer position for 4 minutes under three feedback methods: i) B-mode, ii) display of real-time virtual transducer, iii) blind. The magnitude of displacement over the cine was computed as an estimate of the imaging position error. We also investigated whether transducer coordinates can be used to re-align images due to motion and improve contrast ultrasound perfusion repeatability. A total of 8 patient data were obtained under an IRB for this. Results suggest that tracking can assist operators maintain a steady position during a lengthy acquisition. With blinded acquisition, an average displacement of 4.58 mm (S.D. 2.65 mm) was noted. In contrast, the average displacement for tracking-feedback was comparable to B-mode at 3.48 mm (S.D. 0.8 mm). We also observed that perfusion parameters had better repeatability after re-alignment.
△ Less
Submitted 1 November, 2020;
originally announced November 2020.
-
Computational Enhancement of Molecularly Targeted Contrast-Enhanced Ultrasound: Application to Human Breast Tumor Imaging
Authors:
Andrew A. Berlin,
Mon Young,
Ahmed El Kaffas,
Sam Gambhir,
Amelie Lutz,
Maria Luigia Storto,
Juergen Willmann
Abstract:
Molecularly targeted contrast enhanced ultrasound (mCEUS) is a clinically promising approach for early cancer detection through targeted imaging of VEGFR2 (KDR) receptors. We have developed computational enhancement techniques for mCEUS tailored to address the unique challenges of imaging contrast accumulation in humans. These techniques utilize dynamic analysis to distinguish molecularly bound co…
▽ More
Molecularly targeted contrast enhanced ultrasound (mCEUS) is a clinically promising approach for early cancer detection through targeted imaging of VEGFR2 (KDR) receptors. We have developed computational enhancement techniques for mCEUS tailored to address the unique challenges of imaging contrast accumulation in humans. These techniques utilize dynamic analysis to distinguish molecularly bound contrast agent from other contrast-mode signal sources, enabling analysis of contrast agent accumulation to be performed during contrast bolus arrival when the signal due to molecular binding is strongest.
Applied to the 18 human patient examinations of the first-in-human molecular ultrasound breast lesion study, computational enhancement improved the ability to differentiate between pathology-proven lesion and pathology-proven normal tissue in real-world human examination conditions that involved both patient and probe motion, with improvements in contrast ratio between lesion and normal tissue that in most cases exceed an order of magnitude (10x). Notably, computational enhancement eliminated a false positive result in which tissue leakage signal was misinterpreted by radiologists to be contrast agent accumulation.
△ Less
Submitted 21 June, 2020;
originally announced June 2020.