Skip to main content

Showing 1–8 of 8 results for author: Joshi, A M

Searching in archive eess. Search in all archives.
.
  1. arXiv:2305.12503  [pdf, other

    eess.SY

    Programmable Transimpedance Amplifier with Integrated Bandgap Reference for Glucose Concentration Measurement

    Authors: Riyaz Ahmad, Amit M. Joshi, Dharmendra Boolchandani

    Abstract: For glucose electrochemical sensors, a comprehensive electronics interface is designed and constructed in 0.18 um, CMOS process technology, and 1.5 V supply voltage. This interface includes a programmable readout amplifier and bandgap reference voltage potentiostat circuit. The programmable transimpedance amplifier (PTIA), the proposed readout circuit, provides a large dynamic range and low noise.… ▽ More

    Submitted 21 May, 2023; originally announced May 2023.

    Comments: 17 Pages, 14 Figures

  2. arXiv:2111.11298  [pdf, other

    eess.SP cs.HC cs.LG

    Novel EEG based Schizophrenia Detection with IoMT Framework for Smart Healthcare

    Authors: Geetanjali Sharma, Amit M. Joshi

    Abstract: In the field of neuroscience, Brain activity analysis is always considered as an important area. Schizophrenia(Sz) is a brain disorder that severely affects the thinking, behaviour, and feelings of people all around the world. Electroencephalography (EEG) is proved to be an efficient biomarker in Sz detection. EEG is a non-linear time-seriesi signal and utilizing it for investigation is rather cru… ▽ More

    Submitted 19 November, 2021; originally announced November 2021.

    Comments: 18 pages, 9 Figures

  3. arXiv:2109.04194  [pdf, other

    cs.HC eess.SP

    Novel Time Domain Based Upper-Limb Prosthesis Control using Incremental Learning Approach

    Authors: Sidharth Pancholi, Amit M. Joshi Deepak Joshi, Bradly S. Duerstock

    Abstract: The upper limb of the body is a vital for various kind of activities for human. The complete or partial loss of the upper limb would lead to a significant impact on daily activities of the amputees. EMG carries important information of human physique which helps to decode the various functionalities of human arm. EMG signal based bionics and prosthesis have gained huge research attention over the… ▽ More

    Submitted 13 January, 2024; v1 submitted 25 August, 2021; originally announced September 2021.

    Comments: 15 Pages, 8 Figures, This work has been submitted to the IEEE for possible publication

  4. arXiv:2107.08514  [pdf, other

    eess.SP cs.HC cs.LG q-bio.NC

    Classification of Upper Arm Movements from EEG signals using Machine Learning with ICA Analysis

    Authors: Pranali Kokate, Sidharth Pancholi, Amit M. Joshi

    Abstract: The Brain-Computer Interface system is a profoundly developing area of experimentation for Motor activities which plays vital role in decoding cognitive activities. Classification of Cognitive-Motor Imagery activities from EEG signals is a critical task. Hence proposed a unique algorithm for classifying left/right-hand movements by utilizing Multi-layer Perceptron Neural Network. Handcrafted stati… ▽ More

    Submitted 18 July, 2021; originally announced July 2021.

    Comments: 41 Pages, Figures 32, Table 9

  5. arXiv:2106.02463  [pdf, other

    eess.SP

    A Robust and Accurate Deep Learning based Pattern Recognition Framework for Upper Limb Prosthesis using sEMG

    Authors: Sidharth Pancholi, Amit M. Joshi, Deepak Joshi

    Abstract: In EMG based pattern recognition (EMG-PR), deep learning-based techniques have become more prominent for their self-regulating capability to extract discriminant features from large data-sets. Moreover, the performance of traditional machine learning-based methods show limitation to categorize over a certain number of classes and degrades over a period of time. In this paper, an accurate, robust,… ▽ More

    Submitted 11 June, 2021; v1 submitted 4 June, 2021; originally announced June 2021.

  6. arXiv:2008.11153  [pdf, other

    q-bio.OT eess.SP

    Smart Healthcare for Diabetes: A COVID-19 Perspective

    Authors: Amit M. Joshi, Urvashi P. Shukla, Saraju P. Mohanty

    Abstract: Diabetes is considered as an critical comorbidity linked with the latest coronavirus disease 2019 (COVID-19) which spreads through Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-Cov-2). The diabetic patients have higher threat of infection from novel corona virus. Depending on the region in the globe, 20% to 50% of patients infected with COVID-19 pandemic had diabetes. The current article d… ▽ More

    Submitted 29 July, 2020; originally announced August 2020.

    Comments: 18 pages, 11 figures

    Report number: MCE_COVID_2020

  7. iGLU 2.0: A new non-invasive, accurate serum glucometer for smart healthcare

    Authors: Prateek Jain, Amit M Joshi, Navneet Agrawal, Saraju Mohanty

    Abstract: To best of the authors knowledge, this article presents the first-ever non-invasive glucometer that takes into account serum glucose for high accuracy. In case of blood glucose measurement, serum glucose value has always been considered precise blood glucose value during prandial modes. Serum glucose can be measured in laboratory and more stable glucose level compare to capillary glucose. However,… ▽ More

    Submitted 24 January, 2020; originally announced January 2020.

    Comments: 19 pages, 17 Figures

    Report number: TCE_iGLU_2020

    Journal ref: IEEE Transactions on Consumer Electronics-2020

  8. iGLU 1.0: An Accurate Non-Invasive Near-Infrared Dual Short Wavelengths Spectroscopy based Glucometer for Smart Healthcare

    Authors: Prateek Jain, Amit M. Joshi, Saraju P. Mohanty

    Abstract: In the case of diabetes, fingertip pricking for a blood sample is inconvenient for glucose measurement. Invasive approaches like laboratory test and one-touch glucometer enhance the risk of blood-related infections. To mitigate this important issue, in the current paper, we propose a novel Internet-of-Medical-Things (IoMT) enabled edge-device for precise, non-invasive blood glucose measurement. In… ▽ More

    Submitted 10 November, 2019; originally announced November 2019.

    Report number: MCE_iGLU_2020

    Journal ref: IEEE Consumer Electronics Magazine-2019