Skip to main content

Showing 1–4 of 4 results for author: Jansen, M J A

Searching in archive eess. Search in all archives.
.
  1. arXiv:1910.12753  [pdf, other

    eess.IV q-bio.QM

    Patient-specific fine-tuning of CNNs for follow-up lesion quantification

    Authors: Mariëlle J. A. Jansen, Hugo J. Kuijf, Ashis K. Dhara, Nick A. Weaver, Geert Jan Biessels, Robin Strand, Josien P. W. Pluim

    Abstract: Convolutional neural network (CNN) methods have been proposed to quantify lesions in medical imaging. Commonly more than one imaging examination is available for a patient, but the serial information in these images often remains unused. CNN-based methods have the potential to extract valuable information from previously acquired imaging to better quantify current imaging of the same patient. A pr… ▽ More

    Submitted 28 October, 2019; originally announced October 2019.

  2. arXiv:1910.06635  [pdf, other

    eess.IV cs.CV q-bio.QM

    Liver segmentation and metastases detection in MR images using convolutional neural networks

    Authors: Mariëlle J. A. Jansen, Hugo J. Kuijf, Maarten Niekel, Wouter B. Veldhuis, Frank J. Wessels, Max A. Viergever, Josien P. W. Pluim

    Abstract: Primary tumors have a high likelihood of developing metastases in the liver and early detection of these metastases is crucial for patient outcome. We propose a method based on convolutional neural networks (CNN) to detect liver metastases. First, the liver was automatically segmented using the six phases of abdominal dynamic contrast enhanced (DCE) MR images. Next, DCE-MR and diffusion weighted (… ▽ More

    Submitted 15 October, 2019; originally announced October 2019.

    Journal ref: J. Med. Imag. 6(4), 044003 (2019)

  3. arXiv:1908.08254  [pdf, other

    eess.IV cs.CV

    Motion correction of dynamic contrast enhanced MRI of the liver

    Authors: Mariëlle J. A. Jansen, Wouter B. Veldhuis, Maarten S. van Leeuwen, Josien P. W. Pluim

    Abstract: Motion correction of dynamic contrast enhanced magnetic resonance images (DCE-MRI) is a challenging task, due to changes in image appearance. In this study a groupwise registration, using a principle component analysis (PCA) based metric,1 is evaluated for clinical DCE MRI of the liver. The groupwise registration transforms the images to a common space, rather than to a reference volume as convent… ▽ More

    Submitted 22 August, 2019; originally announced August 2019.

  4. arXiv:1908.08251  [pdf, other

    eess.IV cs.CV

    Optimal input configuration of dynamic contrast enhanced MRI in convolutional neural networks for liver segmentation

    Authors: Mariëlle J. A. Jansen, Hugo J. Kuijf, Josien P. W. Pluim

    Abstract: Most MRI liver segmentation methods use a structural 3D scan as input, such as a T1 or T2 weighted scan. Segmentation performance may be improved by utilizing both structural and functional information, as contained in dynamic contrast enhanced (DCE) MR series. Dynamic information can be incorporated in a segmentation method based on convolutional neural networks in a number of ways. In this study… ▽ More

    Submitted 22 August, 2019; originally announced August 2019.

    Comments: Submitted to SPIE Medical Imaging 2019