-
ReXGradient-160K: A Large-Scale Publicly Available Dataset of Chest Radiographs with Free-text Reports
Authors:
Xiaoman Zhang,
Julián N. Acosta,
Josh Miller,
Ouwen Huang,
Pranav Rajpurkar
Abstract:
We present ReXGradient-160K, representing the largest publicly available chest X-ray dataset to date in terms of the number of patients. This dataset contains 160,000 chest X-ray studies with paired radiological reports from 109,487 unique patients across 3 U.S. health systems (79 medical sites). This comprehensive dataset includes multiple images per study and detailed radiology reports, making i…
▽ More
We present ReXGradient-160K, representing the largest publicly available chest X-ray dataset to date in terms of the number of patients. This dataset contains 160,000 chest X-ray studies with paired radiological reports from 109,487 unique patients across 3 U.S. health systems (79 medical sites). This comprehensive dataset includes multiple images per study and detailed radiology reports, making it particularly valuable for the development and evaluation of AI systems for medical imaging and automated report generation models. The dataset is divided into training (140,000 studies), validation (10,000 studies), and public test (10,000 studies) sets, with an additional private test set (10,000 studies) reserved for model evaluation on the ReXrank benchmark. By providing this extensive dataset, we aim to accelerate research in medical imaging AI and advance the state-of-the-art in automated radiological analysis. Our dataset will be open-sourced at https://huggingface.co/datasets/rajpurkarlab/ReXGradient-160K.
△ Less
Submitted 10 May, 2025; v1 submitted 30 April, 2025;
originally announced May 2025.
-
Seamless Optical Cloud Computing across Edge-Metro Network for Generative AI
Authors:
Sizhe Xing,
Aolong Sun,
Chengxi Wang,
Yizhi Wang,
Boyu Dong,
Junhui Hu,
Xuyu Deng,
An Yan,
Yingjun Liu,
Fangchen Hu,
Zhongya Li,
Ouhan Huang,
Junhao Zhao,
Yingjun Zhou,
Ziwei Li,
Jianyang Shi,
Xi Xiao,
Richard Penty,
Qixiang Cheng,
Nan Chi,
Junwen Zhang
Abstract:
The rapid advancement of generative artificial intelligence (AI) in recent years has profoundly reshaped modern lifestyles, necessitating a revolutionary architecture to support the growing demands for computational power. Cloud computing has become the driving force behind this transformation. However, it consumes significant power and faces computation security risks due to the reliance on exten…
▽ More
The rapid advancement of generative artificial intelligence (AI) in recent years has profoundly reshaped modern lifestyles, necessitating a revolutionary architecture to support the growing demands for computational power. Cloud computing has become the driving force behind this transformation. However, it consumes significant power and faces computation security risks due to the reliance on extensive data centers and servers in the cloud. Reducing power consumption while enhancing computational scale remains persistent challenges in cloud computing. Here, we propose and experimentally demonstrate an optical cloud computing system that can be seamlessly deployed across edge-metro network. By modulating inputs and models into light, a wide range of edge nodes can directly access the optical computing center via the edge-metro network. The experimental validations show an energy efficiency of 118.6 mW/TOPs (tera operations per second), reducing energy consumption by two orders of magnitude compared to traditional electronic-based cloud computing solutions. Furthermore, it is experimentally validated that this architecture can perform various complex generative AI models through parallel computing to achieve image generation tasks.
△ Less
Submitted 1 May, 2025; v1 submitted 4 December, 2024;
originally announced December 2024.
-
Emulating Clinical Quality Muscle B-mode Ultrasound Images from Plane Wave Images Using a Two-Stage Machine Learning Model
Authors:
Reed Chen,
Courtney Trutna Paley,
Wren Wightman,
Lisa Hobson-Webb,
Yohei Harada,
Felix Jin,
Ouwen Huang,
Mark Palmeri,
Kathryn Nightingale
Abstract:
Research ultrasound scanners such as the Verasonics Vantage often lack the advanced image processing algorithms used by clinical systems. Image quality is even lower in plane wave imaging - often used for shear wave elasticity imaging (SWEI) - which sacrifices spatial resolution for temporal resolution. As a result, delay-and-summed images acquired from SWEI have limited interpretability. In this…
▽ More
Research ultrasound scanners such as the Verasonics Vantage often lack the advanced image processing algorithms used by clinical systems. Image quality is even lower in plane wave imaging - often used for shear wave elasticity imaging (SWEI) - which sacrifices spatial resolution for temporal resolution. As a result, delay-and-summed images acquired from SWEI have limited interpretability. In this project, a two-stage machine learning model was trained to enhance single plane wave images of muscle acquired with a Verasonics Vantage system. The first stage of the model consists of a U-Net trained to emulate plane wave compounding, histogram matching, and unsharp masking using paired images. The second stage consists of a CycleGAN trained to emulate clinical muscle B-modes using unpaired images. This two-stage model was implemented on the Verasonics Vantage research ultrasound scanner, and its ability to provide high-speed image formation at a frame rate of 28.5 +/- 0.6 FPS from a single plane wave transmit was demonstrated. A reader study with two physicians demonstrated that these processed images had significantly greater structural fidelity and less speckle than the original plane wave images.
△ Less
Submitted 7 December, 2024;
originally announced December 2024.
-
Edge-guided inverse design of digital metamaterial-based mode multiplexers for high-capacity multi-dimensional interconnect
Authors:
Aolong Sun,
Sizhe Xing,
Xuyu Deng,
Ruoyu Shen,
An Yan,
Fangchen Hu,
Yuqin Yuan,
Boyu Dong,
Junhao Zhao,
Ouhan Huang,
Ziwei Li,
Jianyang Shi,
Yingjun Zhou,
Chao Shen,
Yiheng Zhao,
Bingzhou Hong,
Wei Chu,
Junwen Zhang,
Haiwen Cai,
Nan Chi
Abstract:
The escalating demands of compute-intensive applications urgently necessitate the adoption of optical interconnect technologies to overcome bottlenecks in scaling computing systems. This requires fully exploiting the inherent parallelism of light across scalable dimensions for data loading. Here we experimentally demonstrate a synergy of wavelength- and mode- multiplexing combined with high-order…
▽ More
The escalating demands of compute-intensive applications urgently necessitate the adoption of optical interconnect technologies to overcome bottlenecks in scaling computing systems. This requires fully exploiting the inherent parallelism of light across scalable dimensions for data loading. Here we experimentally demonstrate a synergy of wavelength- and mode- multiplexing combined with high-order modulation formats to achieve multi-tens-of-terabits-per-second optical interconnects using foundry-compatible silicon photonic circuits. Implementing an edge-guided analog-and-digital optimization method that integrates high efficiency with fabrication robustness, we achieve the inverse design of mode multiplexers based on digital metamaterial waveguides. Furthermore, we employ a packaged five-mode multiplexing chip, achieving a single-wavelength interconnect capacity of 1.62 Tbit s-1 and a record-setting multi-dimensional interconnect capacity of 38.2 Tbit s-1 across 5 modes and 88 wavelength channels, with high-order formats up to 8-ary pulse-amplitude-modulation (PAM). This study highlights the transformative potential of optical interconnect technologies to surmount the constraints of electronic links, thus setting the stage for next-generation datacenter and optical compute interconnects.
△ Less
Submitted 26 February, 2025; v1 submitted 9 October, 2024;
originally announced October 2024.
-
MimickNet, Matching Clinical Post-Processing Under Realistic Black-Box Constraints
Authors:
Ouwen Huang,
Will Long,
Nick Bottenus,
Gregg E. Trahey,
Sina Farsiu,
Mark L. Palmeri
Abstract:
Image post-processing is used in clinical-grade ultrasound scanners to improve image quality (e.g., reduce speckle noise and enhance contrast). These post-processing techniques vary across manufacturers and are generally kept proprietary, which presents a challenge for researchers looking to match current clinical-grade workflows. We introduce a deep learning framework, MimickNet, that transforms…
▽ More
Image post-processing is used in clinical-grade ultrasound scanners to improve image quality (e.g., reduce speckle noise and enhance contrast). These post-processing techniques vary across manufacturers and are generally kept proprietary, which presents a challenge for researchers looking to match current clinical-grade workflows. We introduce a deep learning framework, MimickNet, that transforms raw conventional delay-and-summed (DAS) beams into the approximate post-processed images found on clinical-grade scanners. Training MimickNet only requires post-processed image samples from a scanner of interest without the need for explicit pairing to raw DAS data. This flexibility allows it to hypothetically approximate any manufacturer's post-processing without access to the pre-processed data. MimickNet generates images with an average similarity index measurement (SSIM) of 0.930$\pm$0.0892 on a 300 cineloop test set, and it generalizes to cardiac cineloops outside of our train-test distribution achieving an SSIM of 0.967$\pm$0.002. We also explore the theoretical SSIM achievable by evaluating MimickNet performance when trained under gray-box constraints (i.e., when both pre-processed and post-processed images are available). To our knowledge, this is the first work to establish deep learning models that closely approximate current clinical-grade ultrasound post-processing under realistic black-box constraints where before and after post-processing data is unavailable. MimickNet serves as a clinical post-processing baseline for future works in ultrasound image formation to compare against. To this end, we have made the MimickNet software open source.
△ Less
Submitted 15 August, 2019;
originally announced August 2019.