Cartesian dictionary-based native T1 and T2 mapping of the myocardium
Authors:
Markus Henningsson
Abstract:
Purpose: To implement and evaluate a new dictionary-based technique for native myocardial T1 and T2 mapping using Cartesian sampling. Methods: The proposed technique (Multimapping) consisted of single-shot Cartesian image acquisitions in 10 consecutive cardiac cycles, with inversion pulses in cycle 1 and 5, and T2 preparation (TE: 30ms, 50ms and 70ms) in cycles 8-10. Multimapping was simulated for…
▽ More
Purpose: To implement and evaluate a new dictionary-based technique for native myocardial T1 and T2 mapping using Cartesian sampling. Methods: The proposed technique (Multimapping) consisted of single-shot Cartesian image acquisitions in 10 consecutive cardiac cycles, with inversion pulses in cycle 1 and 5, and T2 preparation (TE: 30ms, 50ms and 70ms) in cycles 8-10. Multimapping was simulated for different T1 and T2, where entries corresponding to the k-space centers were matched to acquired data. Experiments were performed in a phantom, 16 healthy subjects and three patients with cardiovascular disease. Results: Multimapping phantom measurements showed good agreement with reference values for both T1 and T2, with no discernable heart-rate dependency for T1 and T2 within the range of myocardium. In vivo mean T1 in healthy subjects was significantly higher using Multimapping (T1=1114+/-14ms) compared to the reference (T1=991+/-26ms) (p<0.01). Mean Multimapping T2 (47.1+/-1.3ms) and T2 spatial variability (5.8+/-1.0ms) was significantly lower compared to the reference (T2=54.7+/-2.2ms, p<0.001; spatial variability=8.4+/-2.0ms, p<0.01). Increased T1 and T2 was detected in all patients using Multimapping. Conclusions: Multimapping allows for simultaneous native myocardial T1 and T2 mapping with a conventional Cartesian trajectory, demonstrating promising in vivo image quality and parameter quantification results.
△ Less
Submitted 22 November, 2021; v1 submitted 5 October, 2021;
originally announced October 2021.
Mechanically Powered Motion Imaging Phantoms: Proof of Concept
Authors:
Alberto Gomez,
Cornelia Schmitz,
Markus Henningsson,
James Housden,
Yohan Noh,
Veronika A. Zimmer,
James R. Clough,
Ilkay Oksuz,
Nicolas Toussaint,
Andrew P. King,
Julia A. Schnabel
Abstract:
Motion imaging phantoms are expensive, bulky and difficult to transport and set-up. The purpose of this paper is to demonstrate a simple approach to the design of multi-modality motion imaging phantoms that use mechanically stored energy to produce motion. We propose two phantom designs that use mainsprings and elastic bands to store energy. A rectangular piece was attached to an axle at the end o…
▽ More
Motion imaging phantoms are expensive, bulky and difficult to transport and set-up. The purpose of this paper is to demonstrate a simple approach to the design of multi-modality motion imaging phantoms that use mechanically stored energy to produce motion. We propose two phantom designs that use mainsprings and elastic bands to store energy. A rectangular piece was attached to an axle at the end of the transmission chain of each phantom, and underwent a rotary motion upon release of the mechanical motor. The phantoms were imaged with MRI and US, and the image sequences were embedded in a 1D non linear manifold (Laplacian Eigenmap) and the spectrogram of the embedding was used to derive the angular velocity over time. The derived velocities were consistent and reproducible within a small error. The proposed motion phantom concept showed great potential for the construction of simple and affordable motion phantoms
△ Less
Submitted 17 May, 2019;
originally announced May 2019.