Damping Wind Farm Resonances with Current Based Model Predictive Pulse Pattern Control
Authors:
Orcun Karaca,
Ioannis Tsoumas,
Tinus Dorfling,
Ran Chen,
Lennart Harnefors
Abstract:
It is well-established that a proportional current control gain emulates a resistor in the converter output impedance. Even though this resistance can provide additional damping to grid resonances, its effect for traditional linear current controllers is known to be rather limited. Moreover, for medium-voltage systems, high switching frequencies are not an option due to the high switching losses.…
▽ More
It is well-established that a proportional current control gain emulates a resistor in the converter output impedance. Even though this resistance can provide additional damping to grid resonances, its effect for traditional linear current controllers is known to be rather limited. Moreover, for medium-voltage systems, high switching frequencies are not an option due to the high switching losses. To meet the harmonic standards, it is expedient to use optimized pulse patterns. This further exacerbates the problems with the resistance of classical controllers, since an additional filtering would be required so that the current controller acts only on the fundamental component (and not on the ripple component). Such a design limits the damping effect not only in its amplitude but also in the frequency range where it is active. This paper shows that a high-bandwidth current-based model predictive pulse pattern controller can alleviate these limitations. The pulse pattern control approach can achieve a high gain even at low switching frequencies, while controlling directly the instantaneous currents (i.e., the fundamental component and the ripple together). With a fast implementation cycle, the frequency range where this damping effect is active can be further extended. Numerical studies showcase these benefits for a multi-phase medium-voltage wind power conversion system.
△ Less
Submitted 21 June, 2024;
originally announced June 2024.
-
Closed-Form Solutions for Grid-Forming Converters: A Design-Oriented Study
Authors:
Fangzhou Zhao,
Tianhua Zhu,
Lennart Harnefors,
Bo Fan,
Heng Wu,
Zichao Zhou,
Yin Sun,
Xiongfei Wang
Abstract:
This paper derives closed-form solutions for grid-forming converters with power synchronization control (PSC) by subtly simplifying and factorizing the complex closed-loop models. The solutions can offer clear analytical insights into control-loop interactions, enabling guidelines for robust controller design. It is proved that 1) the proportional gains of PSC and alternating voltage control (AVC)…
▽ More
This paper derives closed-form solutions for grid-forming converters with power synchronization control (PSC) by subtly simplifying and factorizing the complex closed-loop models. The solutions can offer clear analytical insights into control-loop interactions, enabling guidelines for robust controller design. It is proved that 1) the proportional gains of PSC and alternating voltage control (AVC) can introduce negative resistance, which aggravates synchronous resonance (SR) of power control, 2) the integral gain of AVC is the cause of sub-synchronous resonance (SSR) in stiff-grid interconnections, albeit the proportional gain of AVC can help dampen the SSR, and 3) surprisingly, the current controller that dampens SR actually exacerbates SSR. Controller design guidelines are given based on analytical insights. The findings are verified by simulations and experimental results.
△ Less
Submitted 4 December, 2023;
originally announced December 2023.
-
Influence of Sensor Feedback Limitations on Power Oscillation Damping and Transient Stability
Authors:
Joakim Björk,
Danilo Obradović,
Lennart Harnefors,
Karl Henrik Johansson
Abstract:
Fundamental sensor feedback limitations for improving rotor angle stability using local frequency or phase angle measurement are derived. Using a two-machine power system model, it is shown that improved damping of inter-area oscillations must come at the cost of reduced transient stability margins, regardless of the control design method. The control limitations stem from that the excitation of a…
▽ More
Fundamental sensor feedback limitations for improving rotor angle stability using local frequency or phase angle measurement are derived. Using a two-machine power system model, it is shown that improved damping of inter-area oscillations must come at the cost of reduced transient stability margins, regardless of the control design method. The control limitations stem from that the excitation of an inter-area mode by external disturbances cannot be estimated with certainty using local frequency information. The results are validated on a modified Kundur four-machine two-area test system where the active power is modulated on an embedded high-voltage dc link. Damping control using local phase angle measurements, unavoidably leads to an increased rotor angle deviation following certain load disturbances. For a highly stressed system, it is shown that this may lead to transient instability. The limitations derived in the paper may motivate the need for wide-area measurements in power oscillation damping control.
△ Less
Submitted 12 August, 2021; v1 submitted 8 November, 2019;
originally announced November 2019.