-
Geometric Solution of Image Degradation by Diffraction in Lensless Sensing and Microscopy
Authors:
Sanjeev Kumar,
Manjunatha Mahadevappa,
Pranab Kumar Dutta
Abstract:
This paper proposes a non-computational method of counteracting the effect of image degradation introduced by the diffraction phenomenon in lensless microscopy. All the optical images (whether focused by lenses or not) are diffraction patterns, which preserve the visual information upto a certain extent determined by the size of the point spread functions, like airy disks in some cases. A highly d…
▽ More
This paper proposes a non-computational method of counteracting the effect of image degradation introduced by the diffraction phenomenon in lensless microscopy. All the optical images (whether focused by lenses or not) are diffraction patterns, which preserve the visual information upto a certain extent determined by the size of the point spread functions, like airy disks in some cases. A highly diverging beam can be exploited to reduce the spatial extent of these point spread functions relatively in the transformed projective space, which can help us in the spatial unmixing of the visual information. The principle has been experimentally validated by the lensless imaging of red blood cells of diameter ~6-9 micrometers and a photolithography mask with features in micrometer scale. The important advantages of the proposed approach of non-computational shadow microscopy are the improved depth of field and a drastic increase in the sensor to sample working distance. The imaging method can also be used as a projection technique in the multi-angle optical computed tomography (CT).
△ Less
Submitted 7 April, 2021; v1 submitted 4 November, 2020;
originally announced November 2020.
-
A semi-analytic reconstruction method for Diffuse Optical Tomography
Authors:
Tapan Das,
P. K. Dutta
Abstract:
The Diffuse Optical Tomography (DOT) has received considerable attention in the recent years in the field of biomedical imaging and disease detection. However, imaging through highly diffusive medium is a challenge and stability is always an issue due to the inverse problem. Here a non-linear continous wave (CW) semi-analytic reconstruction method is discussed that used curved-beam paths for tomog…
▽ More
The Diffuse Optical Tomography (DOT) has received considerable attention in the recent years in the field of biomedical imaging and disease detection. However, imaging through highly diffusive medium is a challenge and stability is always an issue due to the inverse problem. Here a non-linear continous wave (CW) semi-analytic reconstruction method is discussed that used curved-beam paths for tomographic imaging with no assumption on inclusion, unlike iterative methods.The non-linear Rosenbrock's function is used to approximate the paths followed by majority photons as curved ones. The modified Beer-Lambert Law (MBLL) in proposed differntial form is used to calculate the absorption coefficient of all the avilable photon paths. The computed values are back-projected along these channels and serve as the basis for image reconstruction without solving the inverse problem. For three-dimensional (3-D) imaging, measurements at three different depths covering the entire depth of the phantom are taken. These slices are stacked together followed by interpolation to form the volumetric image of the phantom to complete the tomographic imaging in its true sense. Numerical simulations, wax phantom experiments with different geometries and contrast are carried out with satisfactory results. This semi-analytic reconstruction method is simple and efficient and is suitable for real-time applications that reqiure fast absorption image reconstruction. The method is compared with the Greedy algorithms for further validation. Also, different performance evaluation matrices are estimated to assess the accuracy of the reconstructed images and the results are rather satisfactory.
△ Less
Submitted 28 March, 2020;
originally announced March 2020.
-
Lensless in-line holographic microscopy with light source of low spatio-temporal coherence
Authors:
Sanjeev Kumar,
Manjunatha Mahadevappa,
Pranab Kumar Dutta
Abstract:
Lensless microscopy with coherent or partially coherent light sources is a well known imaging technique, commonly referred as digital in-line holographic microscopy. In the established methods, both the spatial and temporal coherence of light play a crucial role in determining the resolution of reconstructed object. We report lensless microscopy with a spatially extended white LED, a light source…
▽ More
Lensless microscopy with coherent or partially coherent light sources is a well known imaging technique, commonly referred as digital in-line holographic microscopy. In the established methods, both the spatial and temporal coherence of light play a crucial role in determining the resolution of reconstructed object. We report lensless microscopy with a spatially extended white LED, a light source of low spatial and very low temporal coherence. The wave-field propagation between two parallel planes can be obtained using a convolution operation, where the convolution kernel depends on the object-sensor distance and the characteristics of the light source. For a light source of unknown characteristics, this kernel is an unknown function. In the proposed reconstruction method, we decompose an unknown convolution kernel of very large size (128 X 128) into a small unknown light-source-specific kernel (size 9 X 9) and a known light-source-independent kernel (size 128 X 128). This drastically reduces the number of parameters to be estimated at the system identification step, which has been performed here by one time imaging of the known microscopic objects. Final unknown object estimation has been performed using the upper-bound constrained deconvolution. A lateral resolution of ~1-2 micrometer has been demonstrated.
△ Less
Submitted 9 February, 2020;
originally announced February 2020.
-
EM based Framework for Single-shot Compressive Holography
Authors:
Sanjeev Kumar,
Manjunatha Mahadevappa,
Pranab Kumar Dutta
Abstract:
Lensless in-line holography is a simple, portable, and cost-effective method of imaging especially for the biomedical microscopy applications. We propose a multiplicative gradient descent optimization based method to obtain multi-depth imaging from a single hologram acquired in this imaging system. We further extend the method to achieve phase imaging from a single hologram. Negative-log-likelihoo…
▽ More
Lensless in-line holography is a simple, portable, and cost-effective method of imaging especially for the biomedical microscopy applications. We propose a multiplicative gradient descent optimization based method to obtain multi-depth imaging from a single hologram acquired in this imaging system. We further extend the method to achieve phase imaging from a single hologram. Negative-log-likelihood functional with the assumption of poisson noise has been used as the cost function to be minimized. The ill-posed nature of the problem is handled by the sparse regularization and the upper-bound constraint. The gradient descent optimization requires calculation of the partial derivative of the cost function with respect to a given estimate of the object. A method of obtaining this quantity for holography in both the cases of real object and complex object has been shown. The reconstruction method has been validated using extensive simulation and experimental studies. The comparison with the previously established iterative shrinkage/thresholding algorithm based compressive holography shows that the proposed method has the following advantages: significantly faster convergence rate, better reconstructed image quality and the ability to perform phase imaging.
△ Less
Submitted 9 February, 2020;
originally announced February 2020.
-
Photonic crystal fiber for high resolution lensless in-line holographic microscopy
Authors:
Sanjeev Kumar,
Manjunatha Mahadevappa,
Pranab K. Dutta
Abstract:
We propose to use high numerical aperture single mode optical fibers like photonic crystal fiber for lensless in-line holographic microscopy. Highly divergent beam helps to overcome the spatial sampling limitation of the image sensor. In this paper, a submicron lateral resolution has been demonstrated, with an imaging sensor of pixel pitch 1.12 micrometer and a photonic crystal fiber of mode field…
▽ More
We propose to use high numerical aperture single mode optical fibers like photonic crystal fiber for lensless in-line holographic microscopy. Highly divergent beam helps to overcome the spatial sampling limitation of the image sensor. In this paper, a submicron lateral resolution has been demonstrated, with an imaging sensor of pixel pitch 1.12 micrometer and a photonic crystal fiber of mode field diameter 1.8 micrometer. In earlier methods of single-shot lensless imaging, submicron resolution has been obtained at very small working distance and field of view. The proposed method improves the resolution without compromising the working distance. A working distance of (but not limited to) ~1.7 mm with a field of View ~1.4 mm has been demonstrated.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.