A study on the adequacy of common IQA measures for medical images
Authors:
Anna Breger,
Clemens Karner,
Ian Selby,
Janek Gröhl,
Sören Dittmer,
Edward Lilley,
Judith Babar,
Jake Beckford,
Thomas R Else,
Timothy J Sadler,
Shahab Shahipasand,
Arthikkaa Thavakumar,
Michael Roberts,
Carola-Bibiane Schönlieb
Abstract:
Image quality assessment (IQA) is standard practice in the development stage of novel machine learning algorithms that operate on images. The most commonly used IQA measures have been developed and tested for natural images, but not in the medical setting. Reported inconsistencies arising in medical images are not surprising, as they have different properties than natural images. In this study, we…
▽ More
Image quality assessment (IQA) is standard practice in the development stage of novel machine learning algorithms that operate on images. The most commonly used IQA measures have been developed and tested for natural images, but not in the medical setting. Reported inconsistencies arising in medical images are not surprising, as they have different properties than natural images. In this study, we test the applicability of common IQA measures for medical image data by comparing their assessment to manually rated chest X-ray (5 experts) and photoacoustic image data (2 experts). Moreover, we include supplementary studies on grayscale natural images and accelerated brain MRI data. The results of all experiments show a similar outcome in line with previous findings for medical images: PSNR and SSIM in the default setting are in the lower range of the result list and HaarPSI outperforms the other tested measures in the overall performance. Also among the top performers in our experiments are the full reference measures FSIM, LPIPS and MS-SSIM. Generally, the results on natural images yield considerably higher correlations, suggesting that additional employment of tailored IQA measures for medical imaging algorithms is needed.
△ Less
Submitted 20 December, 2024; v1 submitted 29 May, 2024;
originally announced May 2024.
-
A study of why we need to reassess full reference image quality assessment with medical images
Authors:
Anna Breger,
Ander Biguri,
Malena Sabaté Landman,
Ian Selby,
Nicole Amberg,
Elisabeth Brunner,
Janek Gröhl,
Sepideh Hatamikia,
Clemens Karner,
Lipeng Ning,
Sören Dittmer,
Michael Roberts,
AIX-COVNET Collaboration,
Carola-Bibiane Schönlieb
Abstract:
Image quality assessment (IQA) is indispensable in clinical practice to ensure high standards, as well as in the development stage of machine learning algorithms that operate on medical images. The popular full reference (FR) IQA measures PSNR and SSIM are known and tested for working successfully in many natural imaging tasks, but discrepancies in medical scenarios have been reported in the liter…
▽ More
Image quality assessment (IQA) is indispensable in clinical practice to ensure high standards, as well as in the development stage of machine learning algorithms that operate on medical images. The popular full reference (FR) IQA measures PSNR and SSIM are known and tested for working successfully in many natural imaging tasks, but discrepancies in medical scenarios have been reported in the literature, highlighting the gap between development and actual clinical application. Such inconsistencies are not surprising, as medical images have very different properties than natural images, and PSNR and SSIM have neither been targeted nor properly tested for medical images. This may cause unforeseen problems in clinical applications due to wrong judgment of novel methods. This paper provides a structured and comprehensive overview of examples where PSNR and SSIM prove to be unsuitable for the assessment of novel algorithms using different kinds of medical images, including real-world MRI, CT, OCT, X-Ray, digital pathology and photoacoustic imaging data. Therefore, improvement is urgently needed in particular in this era of AI to increase reliability and explainability in machine learning for medical imaging and beyond. Lastly, we will provide ideas for future research as well as suggesting guidelines for the usage of FR-IQA measures applied to medical images.
△ Less
Submitted 14 March, 2025; v1 submitted 29 May, 2024;
originally announced May 2024.
-
Unsupervised Learning of the Total Variation Flow
Authors:
Tamara G. Grossmann,
Sören Dittmer,
Yury Korolev,
Carola-Bibiane Schönlieb
Abstract:
The total variation (TV) flow generates a scale-space representation of an image based on the TV functional. This gradient flow observes desirable features for images, such as sharp edges and enables spectral, scale, and texture analysis. Solving the TV flow is challenging; one reason is the the non-uniqueness of the subgradients. The standard numerical approach for TV flow requires solving multip…
▽ More
The total variation (TV) flow generates a scale-space representation of an image based on the TV functional. This gradient flow observes desirable features for images, such as sharp edges and enables spectral, scale, and texture analysis. Solving the TV flow is challenging; one reason is the the non-uniqueness of the subgradients. The standard numerical approach for TV flow requires solving multiple non-smooth optimisation problems. Even with state-of-the-art convex optimisation techniques, this is often prohibitively expensive and strongly motivates the use of alternative, faster approaches. Inspired by and extending the framework of physics-informed neural networks (PINNs), we propose the TVflowNET, an unsupervised neural network approach, to approximate the solution of the TV flow given an initial image and a time instance. The TVflowNET requires no ground truth data but rather makes use of the PDE for optimisation of the network parameters. We circumvent the challenges related to the non-uniqueness of the subgradients by additionally learning the related diffusivity term. Our approach significantly speeds up the computation time and we show that the TVflowNET approximates the TV flow solution with high fidelity for different image sizes and image types. Additionally, we give a full comparison of different network architecture designs as well as training regimes to underscore the effectiveness of our approach.
△ Less
Submitted 22 April, 2024; v1 submitted 9 June, 2022;
originally announced June 2022.
-
Deep image prior for 3D magnetic particle imaging: A quantitative comparison of regularization techniques on Open MPI dataset
Authors:
Sören Dittmer,
Tobias Kluth,
Mads Thorstein Roar Henriksen,
Peter Maass
Abstract:
Magnetic particle imaging (MPI) is an imaging modality exploiting the nonlinear magnetization behavior of (super-)paramagnetic nanoparticles to obtain a space- and often also time-dependent concentration of a tracer consisting of these nanoparticles. MPI has a continuously increasing number of potential medical applications. One prerequisite for successful performance in these applications is a pr…
▽ More
Magnetic particle imaging (MPI) is an imaging modality exploiting the nonlinear magnetization behavior of (super-)paramagnetic nanoparticles to obtain a space- and often also time-dependent concentration of a tracer consisting of these nanoparticles. MPI has a continuously increasing number of potential medical applications. One prerequisite for successful performance in these applications is a proper solution to the image reconstruction problem. More classical methods from inverse problems theory, as well as novel approaches from the field of machine learning, have the potential to deliver high-quality reconstructions in MPI. We investigate a novel reconstruction approach based on a deep image prior, which builds on representing the solution by a deep neural network. Novel approaches, as well as variational and iterative regularization techniques, are compared quantitatively in terms of peak signal-to-noise ratios and structural similarity indices on the publicly available Open MPI dataset.
△ Less
Submitted 3 July, 2020;
originally announced July 2020.