Identification of Power System Dynamic Model Parameters using the Fisher Information Matrix
Authors:
Dawn Virginillo,
Asja Derviškadić,
Mario Paolone
Abstract:
The expected decrease in system inertia and frequency stability motivates the development and maintenance of dynamic system models by Transmission System Operators. However, some dynamic model parameters can be unavailable due to market unbundling, or inaccurate due to aging infrastructure, non-documented tuning of controllers, or other factors. In this paper, we propose the use of a numerical app…
▽ More
The expected decrease in system inertia and frequency stability motivates the development and maintenance of dynamic system models by Transmission System Operators. However, some dynamic model parameters can be unavailable due to market unbundling, or inaccurate due to aging infrastructure, non-documented tuning of controllers, or other factors. In this paper, we propose the use of a numerical approximation of the Fisher Information Matrix (nFIM) for efficient inference of dynamic model parameters. Thanks to the proposed numerical implementation, the method is scalable to Electromagnetic Transient (EMT) models, which can quickly become computationally complex even for small study systems. Case studies show that the nFIM is coherent with parameter variances of single- and multi-parameter least-squares estimators when applied to an IEEE 9-bus dynamic model with artificial measurements.
△ Less
Submitted 26 May, 2025;
originally announced May 2025.
-
Functional Basis Analysis for the Characterization of Power System Signal Dynamics: Formulation, Implementation and Validation
Authors:
Alexandra Karpilow,
Asja Derviskadic,
Mario Paolone
Abstract:
With the integration of distributed energy resources and the trend towards low-inertia power grids, the frequency and severity of grid dynamics is expected to increase. Conventional phasor-based signal processing methods are proving to be insufficient in the analysis of non-stationary AC voltage and current waveforms, while the computational complexity of many dynamic signal analysis techniques hi…
▽ More
With the integration of distributed energy resources and the trend towards low-inertia power grids, the frequency and severity of grid dynamics is expected to increase. Conventional phasor-based signal processing methods are proving to be insufficient in the analysis of non-stationary AC voltage and current waveforms, while the computational complexity of many dynamic signal analysis techniques hinders their deployment in operational embedded systems. This paper presents the Functional Basis Analysis (FBA), a signal processing tool capable of capturing the full broadband nature of signal dynamics in power grids while maintaining a streamlined design for real-time monitoring applications. Relying on the Hilbert transform and optimization techniques, the FBA can be user-engineered to identify and characterize combinations of several of the most common signal dynamics in power grids, including amplitude/phase modulations, frequency ramps and steps. This paper describes the theoretical basis and design of the FBA as well as the deployment of the algorithm in embedded hardware systems, with adaptations made to consider latency requirements, finite memory capacity, and fixed-point precision arithmetic. For validation, a PMU calibrator is used to evaluate and compare the algorithm's performance to state-of-the-art static and dynamic phasor methods. The test outcomes demonstrate the FBA method's suitability for implementation in embedded systems to improve grid situational awareness during severe grid events.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Beyond Phasors: Continuous-Spectrum Modeling of Power Systems using the Hilbert Transform
Authors:
Asja Derviškadić,
Guglielmo Frigo,
Mario Paolone
Abstract:
Modern power systems are at risk of largely reducing the inertia of generation assets and prone to experience extreme dynamics. The consequence is that, during electromechanical transients triggered by large contingencies, transmission of electrical power may take place in a broad spectrum well beyond the single fundamental component. Traditional modeling approaches rely on the phasor representati…
▽ More
Modern power systems are at risk of largely reducing the inertia of generation assets and prone to experience extreme dynamics. The consequence is that, during electromechanical transients triggered by large contingencies, transmission of electrical power may take place in a broad spectrum well beyond the single fundamental component. Traditional modeling approaches rely on the phasor representation derived from the Fourier Transform (FT) of the signal under analysis. During large transients, though, FT-based analysis may fail to accurately identify the fundamental component parameters, in terms of amplitude, frequency and phase. In this paper, we propose an alternative approach relying on the Hilbert Transform (HT), that, in view of the possibility to identify the whole spectrum, enables the tracking of signal dynamics. We compare FT- and HT-based approaches during representative operating conditions, i.e., amplitude modulations, frequency ramps and step changes, in synthetic and real-world datasets. We further validate the approaches using a contingency analysis on the IEEE 39-bus.
△ Less
Submitted 26 June, 2019;
originally announced June 2019.
-
PMU-Based ROCOF Measurements: Uncertainty Limits and Metrological Significance in Power System Applications
Authors:
Guglielmo Frigo,
Asja Derviskadic,
Yihui Zuo,
Mario Paolone
Abstract:
In modern power systems, the Rate-of-Change-of-Frequency (ROCOF) may be largely employed in Wide Area Monitoring, Protection and Control (WAMPAC) applications. However, a standard approach towards ROCOF measurements is still missing. In this paper, we investigate the feasibility of Phasor Measurement Units (PMUs) deployment in ROCOF-based applications, with a specific focus on Under-Frequency Load…
▽ More
In modern power systems, the Rate-of-Change-of-Frequency (ROCOF) may be largely employed in Wide Area Monitoring, Protection and Control (WAMPAC) applications. However, a standard approach towards ROCOF measurements is still missing. In this paper, we investigate the feasibility of Phasor Measurement Units (PMUs) deployment in ROCOF-based applications, with a specific focus on Under-Frequency Load-Shedding (UFLS). For this analysis, we select three state-of-the-art window-based synchrophasor estimation algorithms and compare different signal models, ROCOF estimation techniques and window lengths in datasets inspired by real-world acquisitions. In this sense, we are able to carry out a sensitivity analysis of the behavior of a PMU-based UFLS control scheme. Based on the proposed results, PMUs prove to be accurate ROCOF meters, as long as the harmonic and inter-harmonic distortion within the measurement pass-bandwidth is scarce. In the presence of transient events, the synchrophasor model looses its appropriateness as the signal energy spreads over the entire spectrum and cannot be approximated as a sequence of narrow-band components. Finally, we validate the actual feasibility of PMU-based UFLS in a real-time simulated scenario where we compare two different ROCOF estimation techniques with a frequency-based control scheme and we show their impact on the successful grid restoration.
△ Less
Submitted 21 March, 2019;
originally announced March 2019.
-
Under Frequency Load Shedding based on PMU Estimates of Frequency and ROCOF
Authors:
Asja Derviškadić,
Yihui Zuo,
Guglielmo Frigo,
Mario Paolone
Abstract:
The paper describes a distributed under-frequency load shedding and load restoration scheme, that exploits frequency and Rate-of-Change-of-Frequency (ROCOF) measurements produced by Phasor Measurement Units (PMUs) as detectors of a large contingency. The paper further discusses the appropriateness of using the synchrophasor model for estimating ROCOF during fast transients following a severe gener…
▽ More
The paper describes a distributed under-frequency load shedding and load restoration scheme, that exploits frequency and Rate-of-Change-of-Frequency (ROCOF) measurements produced by Phasor Measurement Units (PMUs) as detectors of a large contingency. The paper further discusses the appropriateness of using the synchrophasor model for estimating ROCOF during fast transients following a severe generation-load imbalance. The performance of the proposed relaying scheme is compared with a frequency-only based strategy, by means of a real-time digital simulator implementing the time-domain full-replica model of the IEEE 39 bus system.
△ Less
Submitted 2 May, 2018;
originally announced May 2018.