Optimal Coordination of Flexible DERs in Local Energy and Flexibility Markets to Ensure Social Equity
Authors:
Niloofar Pourghaderi,
Milad Kabirifar,
Payman Dehghanian
Abstract:
Local electricity markets offer a promising solution for integrating renewable energy sources and other distributed energy resources (DERs) into distribution networks. These markets enable the effective utilization of flexible resources by facilitating coordination among various agents. Beyond technical and economic considerations, addressing social equity within these local communities is critica…
▽ More
Local electricity markets offer a promising solution for integrating renewable energy sources and other distributed energy resources (DERs) into distribution networks. These markets enable the effective utilization of flexible resources by facilitating coordination among various agents. Beyond technical and economic considerations, addressing social equity within these local communities is critical and requires dedicated attention in market-clearing frameworks. This paper proposes a social equity-based market-clearing framework for the optimal management of DERs' energy and flexibility within local communities. The proposed framework incorporates consumers' energy burden to ensure fair pricing in energy market clearance. Furthermore, to ensure equity during unbalanced operating conditions, flexible resources are managed in the local flexibility market, ensuring that all participants can trade power fairly under network disturbances. The model is formulated as a second-order cone programming (SOCP) optimization and validated on the IEEE 33-bus test distribution network.
△ Less
Submitted 2 June, 2025;
originally announced June 2025.
-
A Federated Deep Learning Approach for Privacy-Preserving Real-Time Transient Stability Predictions in Power Systems
Authors:
Maeshal Hijazi,
Payman Dehghanian
Abstract:
Maintaining the privacy of power system data is essential for protecting sensitive information and ensuring the operation security of critical infrastructure. Therefore, the adoption of centralized deep learning (DL) transient stability assessment (TSA) frameworks can introduce risks to electric utilities. This is because these frameworks make utility data susceptible to cyber threats and communic…
▽ More
Maintaining the privacy of power system data is essential for protecting sensitive information and ensuring the operation security of critical infrastructure. Therefore, the adoption of centralized deep learning (DL) transient stability assessment (TSA) frameworks can introduce risks to electric utilities. This is because these frameworks make utility data susceptible to cyber threats and communication issues when transmitting data to a central server for training a single TSA model. Additionally, the centralized approach demands significant computational resources, which may not always be readily available. In light of these challenges, this paper introduces a federated DL-based TSA framework designed to identify the operating states of the power system. Instead of local utilities transmitting their data to a central server for centralized model training, they independently train their own TSA models using their respective datasets. Subsequently, the parameters of each local TSA model are sent to a central server for model aggregation, and the resulting model is shared back with the local clients. This approach not only preserves the integrity of local utility data, making it resilient against cyber threats but also reduces the computational demands for local TSA model training. The proposed approach is tested on four local clients each having the IEEE 39-bus test system.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
The Effects of Correctly Modeling Generator Step-Up Transformer Status in Geomagnetic Disturbance Studies
Authors:
Jessica L. Wert,
Pooria Dehghanian,
Jonathan Snodgrass,
Thomas J. Overbye
Abstract:
In order to correctly model the impacts of geomagnetically induced current (GIC) flows, the generator step-up (GSU) transformer status must be properly modeled. In power flow studies, generators are typically removed from service without disconnecting their GSU transformers since the GSU transformer status has little to no impact on the power flow result. In reality, removing a generator from serv…
▽ More
In order to correctly model the impacts of geomagnetically induced current (GIC) flows, the generator step-up (GSU) transformer status must be properly modeled. In power flow studies, generators are typically removed from service without disconnecting their GSU transformers since the GSU transformer status has little to no impact on the power flow result. In reality, removing a generator from service involves also removing its GSU transformer from service. This difference presents a discrepancy between simulated behavior and system observations during geomagnetic disturbance (GMD) events. This paper presents GMD case studies on 2000-bus and 24,000-bus systems in which reactive power losses and geomagnetically induced currents are compared across scenarios in which the GSU transformers for the disconnected generators are either in-service or out-of-service. The results demonstrate a 3.2 to 15.5 percent error in reactive power losses when the GSU status is modeled incorrectly. Discrepancies of up to 95 A per phase for branch GIC flows and 450 A for transformer neutral GIC flows are also observed and visualized.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
Application of Transformer Impedance Correction Tables in Power Flow Studies
Authors:
Pooria Dehghanian,
Ju Hee Yeo,
Jessica Wert,
Hanyue Li,
Komal Shetye,
Thomas J. Overbye
Abstract:
Phase Shifting Transformers (PST) are used to control or block certain flows of real power through phase angle regulation across the device. Its functionality is crucial to special situations such as eliminating loop flow through an area and balancing real power flow between parallel paths. Impedance correction tables are used to model that the impedance of phase shifting transformers often vary a…
▽ More
Phase Shifting Transformers (PST) are used to control or block certain flows of real power through phase angle regulation across the device. Its functionality is crucial to special situations such as eliminating loop flow through an area and balancing real power flow between parallel paths. Impedance correction tables are used to model that the impedance of phase shifting transformers often vary as a function of their phase angle shift. The focus of this paper is to consider the modeling errors if the impact of this changing impedance is ignored. The simulations are tested through different scenarios using a 37-bus test case and a 10,000-bus synthetic power grid. The results verify the important role of impedance correction factor to get more accurate and optimal power solutions.
△ Less
Submitted 2 September, 2020;
originally announced September 2020.