-
Output-only Modal Identification of beams with different boundary condition
Authors:
M. R. Davoodi,
S. A. Mostafavian,
S. R. Nabavian,
GH. R. Jahangiri
Abstract:
Structural Health Monitoring (SHM) evaluates the integrity of a structure by observing its dynamic responses by an array of sensors over time to determine the current health state of the structure. The most important step of SHM is system identification which in civil structures is the identification of modal parameters of structures. Due to numerous limitations of input-output methods, system ide…
▽ More
Structural Health Monitoring (SHM) evaluates the integrity of a structure by observing its dynamic responses by an array of sensors over time to determine the current health state of the structure. The most important step of SHM is system identification which in civil structures is the identification of modal parameters of structures. Due to numerous limitations of input-output methods, system identification of ambient vibration structures using output-only identification techniques has become a key issue in structural health monitoring and assessment of engineering structures. In this paper, four beams with different boundary conditions and with arbitrary loading have been modeled in finite element software, ANSYS, and the responses (Acceleration of nodes) have been achieved. By using these data and the codes written in MATLAB software, the modal parameters (natural frequencies, mode shapes) of the beams are identified with FDD (frequency Domain Decomposition) and PP (Peak Picking) methods and then justified with the results of input-output method which was determined by frequency relation function (FRF). The results indicate a good agreement between the three methods for determining the dynamic characteristics of beams.
△ Less
Submitted 4 September, 2023;
originally announced September 2023.
-
Determining minimum number of required accelerometer for output-only structural identification of frames
Authors:
M. R. Davoodi,
B. Navayi neya,
S. A. Mostafavian,
S. R. Nabavian,
GH. R. Jahangiry
Abstract:
Operational modal analysis (OMA) aims at identifying the modal properties of a structure based on response data of the structure excited by ambient sources. Modal parameters of the ambient vibration structures consist of natural frequencies, mode shapes, and modal damping ratios. In this paper, a typical frame with arbitrary loading has been modeled in finite element software, ANSYS, and the respo…
▽ More
Operational modal analysis (OMA) aims at identifying the modal properties of a structure based on response data of the structure excited by ambient sources. Modal parameters of the ambient vibration structures consist of natural frequencies, mode shapes, and modal damping ratios. In this paper, a typical frame with arbitrary loading has been modeled in finite element software, ANSYS, and the responses (accelerations of nodes) have been achieved. By using these data and the codes written in MATLAB, the modal parameters (natural frequencies, mode shapes) of the beams are identified with FDD (Frequency Domain Decomposition) and PP (Peak Picking) methods and then justified with the results of input-output method which was determined by modal analysis. The results indicate that there is a good agreement between three methods for determining the dynamic characteristics of frames. Then, the minimum number of required accelerometer has been determined that recording the acceleration in that location leads to identifying all the natural frequencies of the frame.
△ Less
Submitted 14 October, 2020;
originally announced October 2020.
-
Effect of noise on output-only modal identification of beams
Authors:
Gholamreza Jahangiri,
Seyed Rasoul Nabavian,
Mohammad Reza Davoodi,
Bahram Navayi Neya,
Seyedamin Mostafavian
Abstract:
In most cases, structural health monitoring depends on the determination of the modal parameters of the first few modes of a structure. The data that are used to identify these modes by output-only methods include the structure response together with noise. The presence of noise in the structure response affects the modal parameters. The current study was undertaken to examine the possibility and…
▽ More
In most cases, structural health monitoring depends on the determination of the modal parameters of the first few modes of a structure. The data that are used to identify these modes by output-only methods include the structure response together with noise. The presence of noise in the structure response affects the modal parameters. The current study was undertaken to examine the possibility and accuracy of identifying the modal parameters of beams in the presence of noise. For this purpose, the modal parameters of the different modes of single-span beams were obtained using output data with different signal-to-noise ratios. The acceleration signals were obtained by transient analysis and then different powers of noise were generated and added to the signals. The modal parameters of the beams were obtained using output-only methods. Parameters having signal-to-noise ratios of greater than 13.98 dB for all modes considered were identified. At a signal-to-noise ratio of -6.02 to 13.98 dB (higher noise level), it was not possible to identify the modal parameters of the first mode of beams, but the parameters of the higher modes were identified with good accuracy.
△ Less
Submitted 18 August, 2020;
originally announced August 2020.