-
Observer-Based Consensus of Nonlinear Positive Multi-Agent Systems with Saturated Control Input
Authors:
Amirreza Zaman,
Wolfgang Birk,
Khalid Tourkey Atta
Abstract:
This paper presents the distributed pinning consensus solution for nonlinear positive multi-agent systems with nonlinear control input by applying observer-based control protocols. The network topology is considered as a directed and fully connected structure. By considering sector input nonlinearities and various forms of topologies, two kinds of state observers involving standard observer and di…
▽ More
This paper presents the distributed pinning consensus solution for nonlinear positive multi-agent systems with nonlinear control input by applying observer-based control protocols. The network topology is considered as a directed and fully connected structure. By considering sector input nonlinearities and various forms of topologies, two kinds of state observers involving standard observer and distributed pinning observer are presented for each regarded nonlinear agent by applying a novel analysis directly dealing with the nonlinear input and nonlinear system dynamics. The measured local output detail outlines the first observer, and the other observer is achieved via the corresponding output detail of its adjacent agents. Based on further observed state details, a distributed pinning observer-based strategy is derived for the leader-follower non-negative global consensus of the nonlinear positive multi-agent system. Additionally, two multi-step algorithms are proposed to set up the observer gains and each protocol criterion. Performance evaluations are provided to confirm the proposed control method and illustrate the effectiveness of the derived non-negative consensus observer-based protocols.
△ Less
Submitted 12 May, 2022;
originally announced May 2022.
-
Reduced-Order Modeling of Thermal Dynamics in District Energy Networks using Spectral Clustering
Authors:
Johan Simonsson,
Khalid Tourkey Atta,
Wolfgang Birk
Abstract:
Simulation of thermal dynamics in city-scale district energy grids often becomes computationally prohibitive for long simulation runs. Current model order reduction methods offer limited interpretability with regards to the non-reduced system, and are not in general applicable for e.g., varying flow rates, multiple producers, or changing flow directions. This article presents a novel method based…
▽ More
Simulation of thermal dynamics in city-scale district energy grids often becomes computationally prohibitive for long simulation runs. Current model order reduction methods offer limited interpretability with regards to the non-reduced system, and are not in general applicable for e.g., varying flow rates, multiple producers, or changing flow directions. This article presents a novel method based on graph theory that approximates the solution of an optimization problem that minimizes the local truncation error for heat transport in the grid. It is shown that the method can be used to reduce the thermal dynamic model of a city-scale energy grid, resulting in a coarser temporal and spatial resolution. The relative root mean square error was 2.3\% for the temperature in the evaluation scenario, comparing the reduced-order system with the non-reduced system at the instances of the coarser time-step.
△ Less
Submitted 21 February, 2022; v1 submitted 18 February, 2022;
originally announced February 2022.
-
A latent variable approach to heat load prediction in thermal grids
Authors:
Johan Simonsson,
Khalid Tourkey Atta,
Dave Zachariah,
Wolfgang Birk
Abstract:
In this paper a new method for heat load prediction in district energy systems is proposed. The method uses a nominal model for the prediction of the outdoor temperature dependent space heating load, and a data driven latent variable model to predict the time dependent residual heat load. The residual heat load arises mainly from time dependent operation of space heating and ventilation, and domes…
▽ More
In this paper a new method for heat load prediction in district energy systems is proposed. The method uses a nominal model for the prediction of the outdoor temperature dependent space heating load, and a data driven latent variable model to predict the time dependent residual heat load. The residual heat load arises mainly from time dependent operation of space heating and ventilation, and domestic hot water production. The resulting model is recursively updated on the basis of a hyper-parameter free implementation that results in a parsimonious model allowing for high computational performance. The approach is applied to a single multi-dwelling building in Lulea, Sweden, predicting the heat load using a relatively small number of model parameters and easily obtained measurements. The results are compared with predictions using an artificial neural network, showing that the proposed method achieves better prediction accuracy for the validation case. Additionally, the proposed methods exhibits explainable behavior through the use of an interpretable physical model.
△ Less
Submitted 13 February, 2020;
originally announced February 2020.