-
Stability results for MIMO LTI systems via Scaled Relative Graphs
Authors:
Eder Baron-Prada,
Adolfo Anta,
Alberto Padoan,
Florian Dörfler
Abstract:
This paper proposes a new approach for stability analysis of multi-input, multi-output (MIMO) feedback systems through Scaled Relative Graphs (SRGs). Unlike traditional methods, such as the Generalized Nyquist Criterion (GNC), which relies on a coupled analysis that requires the multiplication of models, our approach enables the evaluation of system stability in a decoupled fashion and provides an…
▽ More
This paper proposes a new approach for stability analysis of multi-input, multi-output (MIMO) feedback systems through Scaled Relative Graphs (SRGs). Unlike traditional methods, such as the Generalized Nyquist Criterion (GNC), which relies on a coupled analysis that requires the multiplication of models, our approach enables the evaluation of system stability in a decoupled fashion and provides an intuitive, visual representation of system behavior. Our results provide conditions for certifying the stability of feedback MIMO Linear Time-Invariant (LTI) systems.
△ Less
Submitted 31 March, 2025; v1 submitted 17 March, 2025;
originally announced March 2025.
-
Mixed Small Gain and Phase Theorem: A new view using Scale Relative Graphs
Authors:
Eder Baron-Prada,
Adolfo Anta,
Alberto Padoan,
Florian Dörfler
Abstract:
We introduce a novel approach to feedback stability analysis for linear time-invariant (LTI) systems, overcoming the limitations of the sectoriality assumption in the small phase theorem. While phase analysis for single-input single-output (SISO) systems is well-established, multi-input multi-output (MIMO) systems lack a comprehensive phase analysis until recent advances introduced with the small-…
▽ More
We introduce a novel approach to feedback stability analysis for linear time-invariant (LTI) systems, overcoming the limitations of the sectoriality assumption in the small phase theorem. While phase analysis for single-input single-output (SISO) systems is well-established, multi-input multi-output (MIMO) systems lack a comprehensive phase analysis until recent advances introduced with the small-phase theorem.
A limitation of the small-phase theorem is the sectorial condition, which states that an operator's eigenvalues must lie within a specified angle sector of the complex plane. We propose a framework based on Scaled Relative Graphs (SRGs) to remove this assumption. We derive two main results: a graphical set-based stability condition using SRGs and a small-phase theorem with no sectorial assumption. These results broaden the scope of phase analysis and feedback stability for MIMO systems.
△ Less
Submitted 17 March, 2025;
originally announced March 2025.
-
On the damping of power systems during inverter-based blackstart
Authors:
Adolfo Anta,
Diego Cifelli
Abstract:
The massive deployment of inverter-based generation poses several challenges to system operators but also offers new opportunities. In the context of grid recovery, inverter-based generation is expected to take over new responsibilities, as conventional generation that are blackstart capable are being decommissioned. Inverter-based facilities, being very flexible and controllable, have the ability…
▽ More
The massive deployment of inverter-based generation poses several challenges to system operators but also offers new opportunities. In the context of grid recovery, inverter-based generation is expected to take over new responsibilities, as conventional generation that are blackstart capable are being decommissioned. Inverter-based facilities, being very flexible and controllable, have the ability to contribute during grid restoration, although it is still unclear how to deal with the limited ratings of batteries, PV, etc. and how to address nonlinear effects such as inrush currents or harmonics. In this direction, the requirements of grid-forming inverters to comply with black start capabilities are still to be defined. During the first steps of a grid restoration process the dynamics of the grid largely vary from the grid behaviour under normal operation. In particular, the grid is nearly unloaded and therefore poorly damped. Indeed, overvoltages and resonances are a common concern during the energization of long transmission lines. In this work we analyse the spectral properties of unloaded transmission lines, and describe the impact of voltage controllers on the damping of the system. As a byproduct, this analysis can be leveraged to propose high level requirements for grid-forming devices, in order to provide adequate damping during the early stages of a grid restoration process.
△ Less
Submitted 25 May, 2024;
originally announced May 2024.
-
The impact of load placement on grid resonances during grid restoration
Authors:
Adolfo Anta,
Diego Cifelli
Abstract:
As inverter-based generation is being massively deployed in the grid, these type of units have to take over the current roles of conventional generation, including the capability of restoring the grid. In this context, the resonances of the grid during the first steps of a black start can be concerning, given that the grid is lightly loaded. Especially relevant are the low frequency resonances, th…
▽ More
As inverter-based generation is being massively deployed in the grid, these type of units have to take over the current roles of conventional generation, including the capability of restoring the grid. In this context, the resonances of the grid during the first steps of a black start can be concerning, given that the grid is lightly loaded. Especially relevant are the low frequency resonances, that may be excited by the harmonic components of the inverter. A typical strategy to avoid or minimize the effect of such resonances relies on connecting load banks. This was fairly feasible with conventional generation, but given the limited ratings of inverters, the amount of load that can be connected at the beginning is very limited. In this paper we consider the energization of a transmission line, and investigate the optimal location of a load along a line in order to maximize the damping in the system. By analysing the spectral properties as a function of the load location, we formally prove that placing the load in the middle of the transmission line maximizes the damping ratio of the first resonance of the system.
△ Less
Submitted 14 February, 2024;
originally announced February 2024.
-
Frequency Stability of Synchronous Machines and Grid-Forming Power Converters
Authors:
Ali Tayyebi,
Dominic Groß,
Adolfo Anta,
Friederich Kupzog,
Florian Dörfler
Abstract:
An inevitable consequence of the global power system transition towards nearly 100% renewable-based generation is the loss of conventional bulk generation by synchronous machines, their inertia, and accompanying frequency and voltage control mechanisms. This gradual transformation of the power system to a low-inertia system leads to critical challenges in maintaining system stability. Novel contro…
▽ More
An inevitable consequence of the global power system transition towards nearly 100% renewable-based generation is the loss of conventional bulk generation by synchronous machines, their inertia, and accompanying frequency and voltage control mechanisms. This gradual transformation of the power system to a low-inertia system leads to critical challenges in maintaining system stability. Novel control techniques for converters, so-called grid-forming strategies, are expected to address these challenges and replicate functionalities that so far have been provided by synchronous machines. This article presents a low-inertia case study that includes synchronous machines and converters controlled under various grid-forming techniques. In this work 1) the positive impact of the grid-forming converters on the frequency stability of synchronous machines is highlighted, 2) a qualitative analysis which provides insights into the frequency stability of the system is presented, 3) we explore the behavior of the grid-forming controls when imposing the converter dc and ac current limitations, 4) the importance of the dc dynamics in grid-forming control design as well as the critical need for an effective ac current limitation scheme are reported, and lastly 5) we analyze how and when the interaction between the fast grid-forming converter and the slow synchronous machine dynamics can contribute to the system instability
△ Less
Submitted 8 March, 2020;
originally announced March 2020.
-
Beyond low-inertia systems: Massive integration of grid-forming power converters in transmission grids
Authors:
Alessandro Crivellaro,
Ali Tayyebi,
Catalin Gavriluta,
Dominic Groß,
Adolfo Anta,
Friederich Kupzog,
Florian Dörfler
Abstract:
As renewable sources increasingly replace existing conventional generation, the dynamics of the grid drastically changes, posing new challenges for transmission system operations, but also arising new opportunities as converter-based generation is highly controllable in faster timescales. This paper investigates grid stability under the massive integration of grid-forming converters. We utilize de…
▽ More
As renewable sources increasingly replace existing conventional generation, the dynamics of the grid drastically changes, posing new challenges for transmission system operations, but also arising new opportunities as converter-based generation is highly controllable in faster timescales. This paper investigates grid stability under the massive integration of grid-forming converters. We utilize detailed converter and synchronous machine models and describe frequency behavior under different penetration levels. First, we show that the transition from 0% to 100% can be achieved from a frequency stability point of view. This is achieved by re-tuning power system stabilizers at high penetration values. Second, we explore the evolution of the nadir and RoCoF for each generator as a function of the amount of inverter-based generation in the grid. This work sheds some light on two major challenges in low and no-inertia systems: defining novel performance metrics that better characterize grid behaviour, and adapting present paradigms in PSS design.
△ Less
Submitted 7 November, 2019;
originally announced November 2019.
-
System Stability Under Adversarial Injection of Dependent Tasks
Authors:
Vicent Cholvi,
Juan Echagüe,
Antonio Fernández Anta,
Christopher Thraves Caro
Abstract:
In this work, we consider a computational model of a distributed system formed by a set of servers in which jobs, that are continuously arriving, have to be executed. Every job is formed by a set of dependent tasks (i.~e., each task may have to wait for others to be completed before it can be started), each of which has to be executed in one of the servers. The arrival of jobs and their properties…
▽ More
In this work, we consider a computational model of a distributed system formed by a set of servers in which jobs, that are continuously arriving, have to be executed. Every job is formed by a set of dependent tasks (i.~e., each task may have to wait for others to be completed before it can be started), each of which has to be executed in one of the servers. The arrival of jobs and their properties is assumed to be controlled by a bounded adversary, whose only restriction is that it cannot overload any server. This model is a non-trivial generalization of the Adversarial Queuing Theory model of Borodin et al., and, like that model, focuses on the stability of the system: whether the number of jobs pending to be completed is bounded at all times. We show multiple results of stability and instability for this adversarial model under different combinations of the scheduling policy used at the servers, the arrival rate, and the dependence between tasks in the jobs.
△ Less
Submitted 4 October, 2019;
originally announced October 2019.
-
Comparison of Bounds for Optimal PMU Placement for State Estimation in Distribution Grids
Authors:
Miguel Picallo,
Adolfo Anta,
Bart De Schutter
Abstract:
The lack of measurements in distribution grids poses a severe challenge for their monitoring: since there may not be enough sensors to achieve numerical observability, load forecasts (pseudo-measurements) are typically used, and thus an accurate state estimation is not guaranteed. However, an estimation is required to control distribution grids given the increasing amount of distributed generation…
▽ More
The lack of measurements in distribution grids poses a severe challenge for their monitoring: since there may not be enough sensors to achieve numerical observability, load forecasts (pseudo-measurements) are typically used, and thus an accurate state estimation is not guaranteed. However, an estimation is required to control distribution grids given the increasing amount of distributed generation. Therefore, we consider the problem of optimal sensor placement to improve the state estimation accuracy in large-scale, 3-phase coupled, unbalanced distribution grids. This is a combinatorial optimization problem whose optimal solution is unpractical to obtain for large networks. We explore the properties of different metrics in the context of optimal experimental design, like convexity and modularity, to propose and compare several tight lower and upper bounds on the performance of the optimal solution. Moreover, we show how to use these bounds to choose near-optimal solutions. We test the method on two IEEE benchmark test feeders, the 123-bus and the 8500-node feeders, to show the effectiveness of the approach.
△ Less
Submitted 7 August, 2019;
originally announced August 2019.
-
Stochastic Optimal Power Flow in Distribution Grids under Uncertainty from State Estimation
Authors:
Miguel Picallo,
Adolfo Anta,
Bart De Schutter
Abstract:
The increasing amount of controllable generation and consumption in distribution grids poses a severe challenge in keeping voltage values within admissible ranges. Existing approaches have considered different optimal power flow formulations to regulate distributed generation and other controllable elements. Nevertheless, distribution grids are characterized by an insufficient number of sensors, a…
▽ More
The increasing amount of controllable generation and consumption in distribution grids poses a severe challenge in keeping voltage values within admissible ranges. Existing approaches have considered different optimal power flow formulations to regulate distributed generation and other controllable elements. Nevertheless, distribution grids are characterized by an insufficient number of sensors, and state estimation algorithms are required to monitor the grid status. We consider in this paper the combined problem of optimal power flow under state estimation, where the estimation uncertainty results into stochastic constraints for the voltage magnitude levels instead of deterministic ones. To solve the given problem efficiently and to bypass the lack of load measurements, we use a linear approximation of the power flow equations. Moreover, we derive a transformation of the stochastic constraints to make them tractable without being too conservative. A case study shows the success of our approach at keeping voltage within limits, and also shows how ignoring the uncertainty in the estimation can lead to voltage level violations.
△ Less
Submitted 24 July, 2019;
originally announced July 2019.
-
Efficient convex optimization for optimal PMU placement in large distribution grids
Authors:
Miguel Picallo,
Adolfo Anta,
Bart De Schutter
Abstract:
The small amount of measurements in distribution grids makes their monitoring more difficult. Topological observability may not be possible, and thus, pseudo-measurements are needed to perform state estimation, which is required to control elements such as distributed generation or transformers at distribution grids. Therefore, we consider the problem of optimal sensor placement to improve the sta…
▽ More
The small amount of measurements in distribution grids makes their monitoring more difficult. Topological observability may not be possible, and thus, pseudo-measurements are needed to perform state estimation, which is required to control elements such as distributed generation or transformers at distribution grids. Therefore, we consider the problem of optimal sensor placement to improve the state estimation accuracy in large-scale, 3-phase coupled, unbalanced distribution grids. This is an NP-hard optimization problem whose optimal solution is unpractical to obtain for large networks. Therefore, we develop a computationally efficient convex optimization algorithm to compute a lower bound on the possible value of the optimal solution, and thus check the gap between the bound and heuristic solutions. We test the method on a large test feeder, the standard IEEE 8500-node, to show the effectiveness of the approach.
△ Less
Submitted 23 July, 2019; v1 submitted 29 October, 2018;
originally announced October 2018.
-
A Two-Step Distribution System State Estimator with Grid Constraints and Mixed Measurements
Authors:
Miguel Picallo Cruz,
Adolfo Anta,
Ara Panosyan,
Bart De Schutter
Abstract:
In this work we study the problem of State Estimation(SE) in large-scale, 3-phase coupled, unbalanced distribution systems. More specifically, we address the problem of including mixed real-time measurements, synchronized and unsynchronized, from phasor measurement units and smart meters, into existing solutions. We propose a computationally efficient two-step method to update a prior solution usi…
▽ More
In this work we study the problem of State Estimation(SE) in large-scale, 3-phase coupled, unbalanced distribution systems. More specifically, we address the problem of including mixed real-time measurements, synchronized and unsynchronized, from phasor measurement units and smart meters, into existing solutions. We propose a computationally efficient two-step method to update a prior solution using the measurements, while taking into account physical constraint caused by buses with no loads. We test the method on a benchmark test feeder to illustrate the effectiveness of the approach.
△ Less
Submitted 15 May, 2018; v1 submitted 31 March, 2017;
originally announced March 2017.
-
Event-triggered and self-triggered stabilization of distributed networked control systems
Authors:
Romain Postoyan,
Paulo Tabuada,
Dragan Nesic,
Adolfo Anta
Abstract:
Event-triggered and self-triggered control have recently been proposed as implementation strategies that considerably reduce the resources required for control. Although most of the work so far has focused on closing a single control loop, some researchers have started to investigate how these new implementation strategies can be applied when closing multiple-feedback loops in the presence of phys…
▽ More
Event-triggered and self-triggered control have recently been proposed as implementation strategies that considerably reduce the resources required for control. Although most of the work so far has focused on closing a single control loop, some researchers have started to investigate how these new implementation strategies can be applied when closing multiple-feedback loops in the presence of physically distributed sensors and actuators. In this paper, we consider a scenario where the distributed sensors, actuators, and controllers communicate via a shared wired channel. We use our recent prescriptive framework for the event-triggered control of nonlinear systems to develop novel policies suitable for the considered distributed scenario. Afterwards, we explain how self-triggering rules can be deduced from the developed event-triggered strategies.
△ Less
Submitted 28 August, 2011;
originally announced August 2011.
-
Exploiting isochrony in self-triggered control
Authors:
Adolfo Anta,
Paulo Tabuada
Abstract:
Event-triggered control and self-triggered control have been recently proposed as new implementation paradigms that reduce resource usage for control systems. In self-triggered control, the controller is augmented with the computation of the next time instant at which the feedback control law is to be recomputed. Since these execution instants are obtained as a function of the plant state, we effe…
▽ More
Event-triggered control and self-triggered control have been recently proposed as new implementation paradigms that reduce resource usage for control systems. In self-triggered control, the controller is augmented with the computation of the next time instant at which the feedback control law is to be recomputed. Since these execution instants are obtained as a function of the plant state, we effectively close the loop only when it is required to maintain the desired performance, thereby greatly reducing the resources required for control. In this paper we present a new technique for the computation of the execution instants by exploiting the concept of isochronous manifolds, also introduced in this paper. While our previous results showed how homogeneity can be used to compute the execution instants along some directions in the state space, the concept of isochrony allows us to compute the executions instants along every direction in the state space. Moreover, we also show in this paper how to homogenize smooth control systems thus making our results applicable to any smooth control system. The benefits of the proposed approach with respect to existing techniques are analyzed in two examples.
△ Less
Submitted 26 April, 2011; v1 submitted 27 September, 2010;
originally announced September 2010.