-
Adaptive and robust smartphone-based step detection in multiple sclerosis
Authors:
Lorenza Angelini,
Dimitar Stanev,
Marta Płonka,
Rafał Klimas,
Natan Napiórkowski,
Gabriela González Chan,
Lisa Bunn,
Paul S Glazier,
Richard Hosking,
Jenny Freeman,
Jeremy Hobart,
Jonathan Marsden,
Licinio Craveiro,
Mike D Rinderknecht,
Mattia Zanon
Abstract:
Background: Many attempts to validate gait pipelines that process sensor data to detect gait events have focused on the detection of initial contacts only in supervised settings using a single sensor. Objective: To evaluate the performance of a gait pipeline in detecting initial/final contacts using a step detection algorithm adaptive to different test settings, smartphone wear locations, and gait…
▽ More
Background: Many attempts to validate gait pipelines that process sensor data to detect gait events have focused on the detection of initial contacts only in supervised settings using a single sensor. Objective: To evaluate the performance of a gait pipeline in detecting initial/final contacts using a step detection algorithm adaptive to different test settings, smartphone wear locations, and gait impairment levels. Methods: In GaitLab (ISRCTN15993728), healthy controls (HC) and people with multiple sclerosis (PwMS; Expanded Disability Status Scale 0.0-6.5) performed supervised Two-Minute Walk Test [2MWT] (structured in-lab overground and treadmill 2MWT) during two on-site visits carrying six smartphones and unsupervised walking activities (structured and unstructured real-world walking) daily for 10-14 days using a single smartphone. Reference gait data were collected with a motion capture system or Gait Up sensors. The pipeline's performance in detecting initial/final contacts was evaluated through F1 scores and absolute temporal error with respect to reference measurement systems. Results: We studied 35 HC and 93 PwMS. Initial/final contacts were accurately detected across all smartphone wear locations. Median F1 scores for initial/final contacts on in-lab 2MWT were >=98.2%/96.5% in HC and >=98.5%/97.7% in PwMS. F1 scores remained high on structured (HC: 100% [0.3%]/100% [0.2%]; PwMS: 99.5% [1.9%]/99.4% [2.5%]) and unstructured real-world walking (HC: 97.8% [2.6%]/97.8% [2.8%]; PwMS: 94.4% [6.2%]/94.0% [6.5%]). Median temporal errors were <=0.08 s. Neither age, sex, disease severity, walking aid use, nor setting (outdoor/indoor) impacted pipeline performance (all p>0.05). Conclusion: This gait pipeline accurately and consistently detects initial and final contacts in PwMS across different smartphone locations and environments, highlighting its potential for real-world gait assessment.
△ Less
Submitted 17 September, 2025;
originally announced September 2025.
-
Annotation and synchronization of smartphone inertial measurement unit and motion capture data collected in a laboratory setting to study gait and balance
Authors:
Dimitar Stanev,
Rafał Klimas,
Marta Płonka,
Natan Napiórkowski,
Lorenza Angelini,
Tjitske A. Boonstra,
Gabriela Gonzalez Chan,
Jonathan Marsden,
Mike D. Rinderknecht,
Mattia Zanon
Abstract:
Validating smartphone sensor-based tests to study gait and balance against reference measurement systems in a laboratory setting poses several technical challenges related to data quality and data processing. One challenge is to guarantee the correct annotation of the data, which is required to ensure that only data collected during the same test execution are compared across measurement systems i…
▽ More
Validating smartphone sensor-based tests to study gait and balance against reference measurement systems in a laboratory setting poses several technical challenges related to data quality and data processing. One challenge is to guarantee the correct annotation of the data, which is required to ensure that only data collected during the same test execution are compared across measurement systems in subsequent analyses. A second challenge is to accurately synchronize the data across the different systems. Here, we propose innovative solutions for both challenges and illustrate their use in the example of comparing smartphone sensor data collected with the Floodlight technology with data collected with a motion capture system. These solutions form important tools for guaranteeing the data quality and data integrity required for the validation of gait and balance characteristics measured by digital health technology tools such as the Floodlight technology.
△ Less
Submitted 11 November, 2024;
originally announced November 2024.
-
Performance assessment of medical and non-medical CPAP interfaces used during the COVID-19 pandemic
Authors:
Marco Marini,
Lorenzo Capponi,
Ilaria Battistoni,
Tommaso Tocci,
Giulio Tribbiani,
Francesco Merante,
Matteo Francioni,
Maria Vittoria Matassini,
Giulia Pongetti,
Matilda Skhoza,
Luca Angelini,
Roberto Marsili,
Marco Mazzanti,
Gian Piero Perna,
Gianluca Rossi,
Alberto Gili
Abstract:
Background: At the beginning of 2020, a high number of COVID-19 cases affected Italy in a short period, causing a difficult supply of medical equipment. To deal with the problem, many healthcare operators readapted different masks to medical devices, but no experiment was conducted to evaluate their performance. The aims of our study were: to assess the performances of three masks and a CPAP helme…
▽ More
Background: At the beginning of 2020, a high number of COVID-19 cases affected Italy in a short period, causing a difficult supply of medical equipment. To deal with the problem, many healthcare operators readapted different masks to medical devices, but no experiment was conducted to evaluate their performance. The aims of our study were: to assess the performances of three masks and a CPAP helmet in their original configuration and after modifications, in the maintenance of mean pressure and half-amplitude variations using different PEEP valves and to analyse the impact of antibacterial (AB) or antibacterial-viral (ABV) pre-valve PEEP filters on the effective PEEP delivered to the patients. Four pressure ports were installed on each mask (three on helmet), mean values and half amplitudes of pressure were recorded. Tests were performed with any, AB, ABV filter before the PEEP valve. CPAP helmet was the most efficient interface producing more stable mean pressure and less prominent half-amplitude variations but the non-medical masks, especially after the modifications, maintained a stable mean pressure value with only a moderate increase of half-amplitude. The use of AB and ABV filters, produced respectively an increase of 2,23% and 16.5% in mean pressure, compared to no filter condition. CPAP helmet is the most reliable interface in terms of detected performance, but readapted masks can assure almost a similar performance. The use of ABV filters before the PEEP valve significantly increases the detected mean pressure while the AB filters have almost a neutral effect.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.