High-Frequency Capacitive Sensing for Electrohydraulic Soft Actuators
Authors:
Michel R. Vogt,
Maximilian Eberlein,
Clemens C. Christoph,
Felix Baumann,
Fabrice Bourquin,
Wim Wende,
Fabio Schaub,
Amirhossein Kazemipour,
Robert K. Katzschmann
Abstract:
The need for compliant and proprioceptive actuators has grown more evident in pursuing more adaptable and versatile robotic systems. Hydraulically Amplified Self-Healing Electrostatic (HASEL) actuators offer distinctive advantages with their inherent softness and flexibility, making them promising candidates for various robotic tasks, including delicate interactions with humans and animals, biomim…
▽ More
The need for compliant and proprioceptive actuators has grown more evident in pursuing more adaptable and versatile robotic systems. Hydraulically Amplified Self-Healing Electrostatic (HASEL) actuators offer distinctive advantages with their inherent softness and flexibility, making them promising candidates for various robotic tasks, including delicate interactions with humans and animals, biomimetic locomotion, prosthetics, and exoskeletons. This has resulted in a growing interest in the capacitive self-sensing capabilities of HASEL actuators to create miniature displacement estimation circuitry that does not require external sensors. However, achieving HASEL self-sensing for actuation frequencies above 1 Hz and with miniature high-voltage power supplies has remained limited. In this paper, we introduce the F-HASEL actuator, which adds an additional electrode pair used exclusively for capacitive sensing to a Peano-HASEL actuator. We demonstrate displacement estimation of the F-HASEL during high-frequency actuation up to 20 Hz and during external loading using miniaturized circuitry comprised of low-cost off-the-shelf components and a miniature high-voltage power supply. Finally, we propose a circuitry to estimate the displacement of multiple F-HASELs and demonstrate it in a wearable application to track joint rotations of a virtual reality user in real-time.
△ Less
Submitted 8 April, 2024; v1 submitted 5 April, 2024;
originally announced April 2024.
Introduction of accelerated BOIN design and facilitation of its application
Authors:
Masahiro Kojima,
Wu Wende,
Henry Zhao
Abstract:
Purpose: During discussions at the Data Science Roundtable meeting in Japan, there were instances where the adoption of the BOIN design was declined, attributed to the extension of study duration and increased sample size in comparison to the 3+3 design. We introduce an accelerated BOIN design aimed at completing a clinical phase I trial at a pace comparable to the 3+3 design. Additionally, we int…
▽ More
Purpose: During discussions at the Data Science Roundtable meeting in Japan, there were instances where the adoption of the BOIN design was declined, attributed to the extension of study duration and increased sample size in comparison to the 3+3 design. We introduce an accelerated BOIN design aimed at completing a clinical phase I trial at a pace comparable to the 3+3 design. Additionally, we introduce how we could have applied the BOIN design within our company, which predominantly utilized the 3+3 design for most of its clinical oncology dose escalation trials. Methods: The accelerated BOIN design is adaptable by using efficiently designated stopping criterion for the existing BOIN framework. Our approach is to terminate the dose escalation study if the number of evaluable patients treated at the current dose reaches 6 and the decision is to stay at the current dose for the next cohort of patients. In addition, for lower dosage levels, considering a cohort size smaller than 3 may be feasible when there are no safety concerns from non-clinical studies. We demonstrate the accelerated BOIN design using a case study and subsequently evaluate the performance of our proposed design through a simulation study. Results: In the simulation study, the average difference in the percentage of correct MTD selection between the accelerated BOIN design and the standard BOIN design was -2.43%, the average study duration and the average sample size of the accelerated BOIN design was reduced by 14.8 months and 9.22 months, respectively, compared with the standard BOIN design. Conclusion: We conclude that our proposed accelerated BOIN design not only provides superior operating characteristics but also enables the study to be completed as fast as the 3+3 design.
△ Less
Submitted 31 August, 2023;
originally announced September 2023.