Fully automated workflow for designing patient-specific orthopaedic implants: application to total knee arthroplasty
Authors:
Aziliz Guezou-Philippe,
Arnaud Clavé,
Ehouarn Maguet,
Ludivine Maintier,
Charles Garraud,
Jean-Rassaire Fouefack,
Valérie Burdin,
Eric Stindel,
Guillaume Dardenne
Abstract:
Background. Osteoarthritis affects about 528 million people worldwide, causing pain and stiffness in the joints. Arthroplasty is commonly performed to treat joint osteoarthritis, reducing pain and improving mobility. Nevertheless, a significant share of patients remain unsatisfied with their surgery. Personalised arthroplasty was introduced to improve surgical outcomes however current solutions re…
▽ More
Background. Osteoarthritis affects about 528 million people worldwide, causing pain and stiffness in the joints. Arthroplasty is commonly performed to treat joint osteoarthritis, reducing pain and improving mobility. Nevertheless, a significant share of patients remain unsatisfied with their surgery. Personalised arthroplasty was introduced to improve surgical outcomes however current solutions require delays, making it difficult to integrate in clinical routine. We propose a fully automated workflow to design patient-specific implants for total knee arthroplasty.
Methods. The proposed pipeline first uses artificial neural networks to segment the femur and tibia proximal and distal extremities. Then the full bones are reconstructed using augmented statistical shape models, combining shape and landmarks information. Finally, 77 morphological parameters are computed to design patient-specific implants. The developed workflow has been trained on 91 CT scans and evaluated on 41 CT scans, in terms of accuracy and execution time.
Results. The workflow accuracy was $0.4\pm0.2mm$ for segmentation, $1.0\pm0.3mm$ for full bone reconstruction, and $2.2\pm1.5mm$ for anatomical landmarks determination. The custom implants fitted the patients' anatomy with $0.9\pm0.5mm$ accuracy. The whole process from segmentation to implants' design lasted about 15 minutes.
Conclusion. The proposed workflow performs a fast and reliable personalisation of knee implants, directly from a CT image without requiring any manual intervention. It allows the establishment of a patient-specific pre-operative planning in a very short time, making it easily available for all patients. Combined with efficient implant manufacturing techniques, this solution could help answer the growing number of arthroplasties while reducing complications and improving patients' satisfaction.
△ Less
Submitted 7 January, 2025; v1 submitted 22 March, 2024;
originally announced March 2024.
Making the best of data derived from a daily practice in clinical legal medicine for research and practice - the example of Spe3dLab
Authors:
Vincent Laugier,
Eric Stindel,
Alcibiade Lichterowicz,
Séverine Ansart,
Thomas Lefèvre
Abstract:
Forensic science suffers from a lack of studies with high-quality design, such as randomized controlled trials (RCT). Evidence in forensic science may be of insufficient quality, which is a major concern. Results from RCT are criticized for providing artificial results that are not useful in real life and unfit for individualized prescription. Various sources of collected data (e.g. data collected…
▽ More
Forensic science suffers from a lack of studies with high-quality design, such as randomized controlled trials (RCT). Evidence in forensic science may be of insufficient quality, which is a major concern. Results from RCT are criticized for providing artificial results that are not useful in real life and unfit for individualized prescription. Various sources of collected data (e.g. data collected in routine practice) could be exploited for distinct goals. Obstacles remain before such data can be practically accessed and used, including technical issues. We present an easy-to-use software dedicated to innovative data analyses for practitioners and researchers. We provide 2 examples in forensics. Spe3dLab has been developed by 3 French teams: a bioinformatics laboratory (LaTIM), a private partner (Tekliko) and a department of forensic medicine (Jean Verdier Hospital). It was designed to be open source, relying on documented and maintained libraries, query-oriented and capable of handling the entire data process from capture to export of best predictive models for their integration in information systems. Spe3dLab was used for 2 specific forensics applications: i) the search for multiple causal factors and ii) the best predictive model of the functional impairment (total incapacity to work, TIW) of assault survivors. 2,892 patients were included over a 6-month period. Time to evaluation was the only direct cause identified for TIW, and victim category was an indirect cause. The specificity and sensitivity of the predictive model were 99.9% and 90%, respectively. Spe3dLab is a quick and efficient tool for accessing observational, routinely collected data and performing innovative analyses. Analyses can be exported for validation and routine use by practitioners, e.g., for computer-aided evaluation of complex problems. It can provide a fully integrated solution for individualized medicine.
△ Less
Submitted 26 July, 2017;
originally announced July 2017.