Skip to main content

Showing 1–12 of 12 results for author: Sinusas, A J

Searching in archive cs. Search in all archives.
.
  1. arXiv:2505.09564  [pdf, ps, other

    cs.CV

    Using Foundation Models as Pseudo-Label Generators for Pre-Clinical 4D Cardiac CT Segmentation

    Authors: Anne-Marie Rickmann, Stephanie L. Thorn, Shawn S. Ahn, Supum Lee, Selen Uman, Taras Lysyy, Rachel Burns, Nicole Guerrera, Francis G. Spinale, Jason A. Burdick, Albert J. Sinusas, James S. Duncan

    Abstract: Cardiac image segmentation is an important step in many cardiac image analysis and modeling tasks such as motion tracking or simulations of cardiac mechanics. While deep learning has greatly advanced segmentation in clinical settings, there is limited work on pre-clinical imaging, notably in porcine models, which are often used due to their anatomical and physiological similarity to humans. Howeve… ▽ More

    Submitted 14 May, 2025; originally announced May 2025.

    Comments: accepted at FIMH 2025

  2. arXiv:2402.09567  [pdf, other

    eess.IV cs.CV

    TAI-GAN: A Temporally and Anatomically Informed Generative Adversarial Network for early-to-late frame conversion in dynamic cardiac PET inter-frame motion correction

    Authors: Xueqi Guo, Luyao Shi, Xiongchao Chen, Qiong Liu, Bo Zhou, Huidong Xie, Yi-Hwa Liu, Richard Palyo, Edward J. Miller, Albert J. Sinusas, Lawrence H. Staib, Bruce Spottiswoode, Chi Liu, Nicha C. Dvornek

    Abstract: Inter-frame motion in dynamic cardiac positron emission tomography (PET) using rubidium-82 (82-Rb) myocardial perfusion imaging impacts myocardial blood flow (MBF) quantification and the diagnosis accuracy of coronary artery diseases. However, the high cross-frame distribution variation due to rapid tracer kinetics poses a considerable challenge for inter-frame motion correction, especially for ea… ▽ More

    Submitted 14 February, 2024; originally announced February 2024.

    Comments: Under revision at Medical Image Analysis

  3. arXiv:2401.13140  [pdf, other

    eess.IV cs.CV

    Dual-Domain Coarse-to-Fine Progressive Estimation Network for Simultaneous Denoising, Limited-View Reconstruction, and Attenuation Correction of Cardiac SPECT

    Authors: Xiongchao Chen, Bo Zhou, Xueqi Guo, Huidong Xie, Qiong Liu, James S. Duncan, Albert J. Sinusas, Chi Liu

    Abstract: Single-Photon Emission Computed Tomography (SPECT) is widely applied for the diagnosis of coronary artery diseases. Low-dose (LD) SPECT aims to minimize radiation exposure but leads to increased image noise. Limited-view (LV) SPECT, such as the latest GE MyoSPECT ES system, enables accelerated scanning and reduces hardware expenses but degrades reconstruction accuracy. Additionally, Computed Tomog… ▽ More

    Submitted 23 January, 2024; originally announced January 2024.

    Comments: 11 Pages, 10 figures, 4 tables

  4. arXiv:2312.00837  [pdf, other

    eess.IV cs.CV

    Adaptive Correspondence Scoring for Unsupervised Medical Image Registration

    Authors: Xiaoran Zhang, John C. Stendahl, Lawrence Staib, Albert J. Sinusas, Alex Wong, James S. Duncan

    Abstract: We propose an adaptive training scheme for unsupervised medical image registration. Existing methods rely on image reconstruction as the primary supervision signal. However, nuisance variables (e.g. noise and covisibility), violation of the Lambertian assumption in physical waves (e.g. ultrasound), and inconsistent image acquisition can all cause a loss of correspondence between medical images. As… ▽ More

    Submitted 17 July, 2024; v1 submitted 30 November, 2023; originally announced December 2023.

    Comments: ECCV 2024 camera-ready version

  5. arXiv:2312.00836  [pdf, other

    eess.IV cs.CV

    Heteroscedastic Uncertainty Estimation Framework for Unsupervised Registration

    Authors: Xiaoran Zhang, Daniel H. Pak, Shawn S. Ahn, Xiaoxiao Li, Chenyu You, Lawrence H. Staib, Albert J. Sinusas, Alex Wong, James S. Duncan

    Abstract: Deep learning methods for unsupervised registration often rely on objectives that assume a uniform noise level across the spatial domain (e.g. mean-squared error loss), but noise distributions are often heteroscedastic and input-dependent in real-world medical images. Thus, this assumption often leads to degradation in registration performance, mainly due to the undesired influence of noise-induce… ▽ More

    Submitted 17 July, 2024; v1 submitted 30 November, 2023; originally announced December 2023.

    Comments: MICCAI 2024 camera-ready version

  6. arXiv:2308.12443  [pdf, other

    eess.IV cs.CV cs.LG

    TAI-GAN: Temporally and Anatomically Informed GAN for early-to-late frame conversion in dynamic cardiac PET motion correction

    Authors: Xueqi Guo, Luyao Shi, Xiongchao Chen, Bo Zhou, Qiong Liu, Huidong Xie, Yi-Hwa Liu, Richard Palyo, Edward J. Miller, Albert J. Sinusas, Bruce Spottiswoode, Chi Liu, Nicha C. Dvornek

    Abstract: The rapid tracer kinetics of rubidium-82 ($^{82}$Rb) and high variation of cross-frame distribution in dynamic cardiac positron emission tomography (PET) raise significant challenges for inter-frame motion correction, particularly for the early frames where conventional intensity-based image registration techniques are not applicable. Alternatively, a promising approach utilizes generative methods… ▽ More

    Submitted 23 August, 2023; originally announced August 2023.

    Comments: Accepted by Simulation and Synthesis in Medical Imaging (SASHIMI 2023, MICCAI workshop), preprint version

  7. arXiv:2305.10328  [pdf, other

    cs.CV

    Joint Denoising and Few-angle Reconstruction for Low-dose Cardiac SPECT Using a Dual-domain Iterative Network with Adaptive Data Consistency

    Authors: Xiongchao Chen, Bo Zhou, Huidong Xie, Xueqi Guo, Qiong Liu, Albert J. Sinusas, Chi Liu

    Abstract: Myocardial perfusion imaging (MPI) by single-photon emission computed tomography (SPECT) is widely applied for the diagnosis of cardiovascular diseases. Reducing the dose of the injected tracer is essential for lowering the patient's radiation exposure, but it will lead to increased image noise. Additionally, the latest dedicated cardiac SPECT scanners typically acquire projections in fewer angles… ▽ More

    Submitted 17 May, 2023; originally announced May 2023.

    Comments: 13 pages, 8 figures, 3 tables

  8. arXiv:2305.10326  [pdf, other

    cs.CV

    Cross-domain Iterative Network for Simultaneous Denoising, Limited-angle Reconstruction, and Attenuation Correction of Low-dose Cardiac SPECT

    Authors: Xiongchao Chen, Bo Zhou, Huidong Xie, Xueqi Guo, Qiong Liu, Albert J. Sinusas, Chi Liu

    Abstract: Single-Photon Emission Computed Tomography (SPECT) is widely applied for the diagnosis of ischemic heart diseases. Low-dose (LD) SPECT aims to minimize radiation exposure but leads to increased image noise. Limited-angle (LA) SPECT enables faster scanning and reduced hardware costs but results in lower reconstruction accuracy. Additionally, computed tomography (CT)-derived attenuation maps ($μ$-ma… ▽ More

    Submitted 17 May, 2023; originally announced May 2023.

    Comments: 12 pages, 7 figures, 4 tables

  9. arXiv:2206.12344  [pdf, other

    eess.IV cs.CV cs.LG

    Segmentation-free PVC for Cardiac SPECT using a Densely-connected Multi-dimensional Dynamic Network

    Authors: Huidong Xie, Zhao Liu, Luyao Shi, Kathleen Greco, Xiongchao Chen, Bo Zhou, Attila Feher, John C. Stendahl, Nabil Boutagy, Tassos C. Kyriakides, Ge Wang, Albert J. Sinusas, Chi Liu

    Abstract: In nuclear imaging, limited resolution causes partial volume effects (PVEs) that affect image sharpness and quantitative accuracy. Partial volume correction (PVC) methods incorporating high-resolution anatomical information from CT or MRI have been demonstrated to be effective. However, such anatomical-guided methods typically require tedious image registration and segmentation steps. Accurately s… ▽ More

    Submitted 3 December, 2022; v1 submitted 24 June, 2022; originally announced June 2022.

    Comments: 12 pages, 11 figures. Accepted for publication at IEEE Transactions on Medical Imaging

  10. arXiv:2206.05278  [pdf, other

    eess.IV cs.AI cs.CV

    Dual-Branch Squeeze-Fusion-Excitation Module for Cross-Modality Registration of Cardiac SPECT and CT

    Authors: Xiongchao Chen, Bo Zhou, Huidong Xie, Xueqi Guo, Jiazhen Zhang, Albert J. Sinusas, John A. Onofrey, Chi liu

    Abstract: Single-photon emission computed tomography (SPECT) is a widely applied imaging approach for diagnosis of coronary artery diseases. Attenuation maps (u-maps) derived from computed tomography (CT) are utilized for attenuation correction (AC) to improve diagnostic accuracy of cardiac SPECT. However, SPECT and CT are obtained sequentially in clinical practice, which potentially induces misregistration… ▽ More

    Submitted 9 June, 2022; originally announced June 2022.

    Comments: 10 pages, 4 figures, accepted at MICCAI 2022

  11. arXiv:1807.04807  [pdf, other

    cs.CV

    Learning-based Regularization for Cardiac Strain Analysis with Ability for Domain Adaptation

    Authors: Allen Lu, Nripesh Parajuli, Maria Zontak, John Stendahl, Kevinminh Ta, Zhao Liu, Nabil Boutagy, Geng-Shi Jeng, Imran Alkhalil, Lawrence H. Staib, Matthew O'Donnell, Albert J. Sinusas, James S. Duncan

    Abstract: Reliable motion estimation and strain analysis using 3D+time echocardiography (4DE) for localization and characterization of myocardial injury is valuable for early detection and targeted interventions. However, motion estimation is difficult due to the low-SNR that stems from the inherent image properties of 4DE, and intelligent regularization is critical for producing reliable motion estimates.… ▽ More

    Submitted 12 July, 2018; originally announced July 2018.

  12. arXiv:1807.02951  [pdf, other

    cs.CV

    Flow Network Tracking for Spatiotemporal and Periodic Point Matching: Applied to Cardiac Motion Analysis

    Authors: Nripesh Parajuli, Allen Lu, Kevinminh Ta, John C. Stendahl, Nabil Boutagy, Imran Alkhalil, Melissa Eberle, Geng-Shi Jeng, Maria Zontak, Matthew ODonnell, Albert J. Sinusas, James S. Duncan

    Abstract: The accurate quantification of left ventricular (LV) deformation/strain shows significant promise for quantitatively assessing cardiac function for use in diagnosis and therapy planning (Jasaityte et al., 2013). However, accurate estimation of the displacement of myocardial tissue and hence LV strain has been challenging due to a variety of issues, including those related to deriving tracking toke… ▽ More

    Submitted 9 July, 2018; originally announced July 2018.

    Comments: Submitted manuscript to Medical Image Analysis Journal