-
GKAN: Explainable Diagnosis of Alzheimer's Disease Using Graph Neural Network with Kolmogorov-Arnold Networks
Authors:
Tianqi Ding,
Dawei Xiang,
Keith E Schubert,
Liang Dong
Abstract:
Alzheimer's Disease (AD) is a progressive neurodegenerative disorder that poses significant diagnostic challenges due to its complex etiology. Graph Convolutional Networks (GCNs) have shown promise in modeling brain connectivity for AD diagnosis, yet their reliance on linear transformations limits their ability to capture intricate nonlinear patterns in neuroimaging data. To address this, we propo…
▽ More
Alzheimer's Disease (AD) is a progressive neurodegenerative disorder that poses significant diagnostic challenges due to its complex etiology. Graph Convolutional Networks (GCNs) have shown promise in modeling brain connectivity for AD diagnosis, yet their reliance on linear transformations limits their ability to capture intricate nonlinear patterns in neuroimaging data. To address this, we propose GCN-KAN, a novel single-modal framework that integrates Kolmogorov-Arnold Networks (KAN) into GCNs to enhance both diagnostic accuracy and interpretability. Leveraging structural MRI data, our model employs learnable spline-based transformations to better represent brain region interactions. Evaluated on the Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset, GCN-KAN outperforms traditional GCNs by 4-8% in classification accuracy while providing interpretable insights into key brain regions associated with AD. This approach offers a robust and explainable tool for early AD diagnosis.
△ Less
Submitted 1 April, 2025;
originally announced April 2025.
-
Algebra of N-event synchronization
Authors:
Ernesto Gomez,
Keith E. Schubert,
Khalil Dajani
Abstract:
We have previously defined synchronization (Gomez, E. and K. Schubert 2011) as a relation between the times at which a pair of events can happen, and introduced an algebra that covers all possible relations for such pairs. In this work we introduce the synchronization matrix, to make it easier to calculate the properties and results of $N$ event synchronizations, such as are commonly encountered i…
▽ More
We have previously defined synchronization (Gomez, E. and K. Schubert 2011) as a relation between the times at which a pair of events can happen, and introduced an algebra that covers all possible relations for such pairs. In this work we introduce the synchronization matrix, to make it easier to calculate the properties and results of $N$ event synchronizations, such as are commonly encountered in parallel execution of multiple processes. The synchronization matrix leads to the definition of N-event synchronization algebras as specific extensions to the original algebra. We derive general properties of such synchronization, and we are able to analyze effects of synchronization on the phase space of parallel execution introduced in (Gomez E Kai R, Schubert KE 2017)
△ Less
Submitted 1 November, 2022;
originally announced November 2022.
-
Developments in Mathematical Algorithms and Computational Tools for Proton CT and Particle Therapy Treatment Planning
Authors:
Yair Censor,
Keith E. Schubert,
Reinhard W. Schulte
Abstract:
We summarize recent results and ongoing activities in mathematical algorithms and computer science methods related to proton computed tomography (pCT) and intensity-modulated particle therapy (IMPT) treatment planning. Proton therapy necessitates a high level of delivery accuracy to exploit the selective targeting imparted by the Bragg peak. For this purpose, pCT utilizes the proton beam itself to…
▽ More
We summarize recent results and ongoing activities in mathematical algorithms and computer science methods related to proton computed tomography (pCT) and intensity-modulated particle therapy (IMPT) treatment planning. Proton therapy necessitates a high level of delivery accuracy to exploit the selective targeting imparted by the Bragg peak. For this purpose, pCT utilizes the proton beam itself to create images. The technique works by sending a low-intensity beam of protons through the patient and measuring the position, direction, and energy loss of each exiting proton. The pCT technique allows reconstruction of the volumetric distribution of the relative stopping power (RSP) of the patient tissues for use in treatment planning and pre-treatment range verification. We have investigated new ways to make the reconstruction both efficient and accurate. Better accuracy of RSP also enables more robust inverse approaches to IMPT. For IMPT, we developed a framework for performing intensity-modulation of the proton pencil beams. We expect that these developments will lead to additional project work in the years to come, which requires a regular exchange between experts in the fields of mathematics, computer science, and medical physics. We have initiated such an exchange by organizing annual workshops on pCT and IMPT algorithm and technology developments. This report is, admittedly, tilted toward our interdisciplinary work and methods. We offer a comprehensive overview of results, problems, and challenges in pCT and IMPT with the aim of making other scientists wanting to tackle such issues and to strengthen their interdisciplinary collaboration by bringing together cutting-edge know-how from medicine, computer science, physics, and mathematics to bear on medical physics problems at hand.
△ Less
Submitted 21 August, 2021;
originally announced August 2021.
-
An Improved Method of Total Variation Superiorization Applied to Reconstruction in Proton Computed Tomography
Authors:
Blake Schultze,
Yair Censor,
Paniz Karbasi,
Keith E. Schubert,
Reinhard W. Schulte
Abstract:
Previous work showed that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this work investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structural and parametric changes introduced to the original TVS algorithm included: (1) inc…
▽ More
Previous work showed that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this work investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structural and parametric changes introduced to the original TVS algorithm included: (1) inclusion or exclusion of TV reduction requirement, (2) a variable number, $N$, of TV perturbation steps per feasibility-seeking iteration, and (3) introduction of a perturbation kernel $0<α<1$. The structural change of excluding the TV reduction requirement check tended to have a beneficial effect for $3\le N\le 6$ and allows full parallelization of the TVS algorithm. Repeated perturbations per feasibility-seeking iterations reduced total variation (TV) and material dependent standard deviations for $3\le N\le 6$. The perturbation kernel $α$, equivalent to $α=0.5$ in the original TVS algorithm, reduced TV and standard deviations as $α$ was increased beyond $α=0.5$, but negatively impacted reconstructed relative stopping power (RSP) values for $α>0.75$. The reductions in TV and standard deviations allowed feasibility-seeking with a larger relaxation parameter $λ$ than previously used, without the corresponding increases in standard deviations experienced with the original TVS algorithm. This work demonstrates that the modifications related to the evolution of the original TVS algorithm provide benefits in terms of both pCT image quality and computational efficiency for appropriately chosen parameter values.
△ Less
Submitted 17 January, 2019; v1 submitted 3 March, 2018;
originally announced March 2018.
-
A Highly Accelerated Parallel Multi-GPU based Reconstruction Algorithm for Generating Accurate Relative Stopping Powers
Authors:
Paniz Karbasi,
Ritchie Cai,
Blake Schultze,
Hanh Nguyen,
Jones Reed,
Patrick Hall,
Valentina Giacometti,
Vladimir Bashkirov,
Robert Johnson,
Nick Karonis,
Jeffrey Olafsen,
Caesar Ordonez,
Keith E. Schubert,
Reinhard W. Schulte
Abstract:
Low-dose Proton Computed Tomography (pCT) is an evolving imaging modality that is used in proton therapy planning which addresses the range uncertainty problem. The goal of pCT is generating a 3D map of Relative Stopping Power (RSP) measurements with high accuracy within clinically required time frames. Generating accurate RSP values within the shortest amount of time is considered a key goal when…
▽ More
Low-dose Proton Computed Tomography (pCT) is an evolving imaging modality that is used in proton therapy planning which addresses the range uncertainty problem. The goal of pCT is generating a 3D map of Relative Stopping Power (RSP) measurements with high accuracy within clinically required time frames. Generating accurate RSP values within the shortest amount of time is considered a key goal when developing a pCT software. The existing pCT softwares have successfully met this time frame and even succeeded this time goal, but requiring clusters with hundreds of processors.
This paper describes a novel reconstruction technique using two Graphics Processing Unit (GPU) cores, such as is available on a single Nvidia P100. The proposed reconstruction technique is tested on both simulated and experimental datasets and on two different systems namely Nvidia K40 and P100 GPUs from IBM and Cray. The experimental results demonstrate that our proposed reconstruction method meets both the timing and accuracy with the benefit of having reasonable cost, and efficient use of power.
△ Less
Submitted 3 February, 2018;
originally announced February 2018.
-
Performance of Hull-Detection Algorithms For Proton Computed Tomography Reconstruction
Authors:
Blake Schultze,
Micah Witt,
Yair Censor,
Reinhard Schulte,
Keith Evan Schubert
Abstract:
Proton computed tomography (pCT) is a novel imaging modality developed for patients receiving proton radiation therapy. The purpose of this work was to investigate hull-detection algorithms used for preconditioning of the large and sparse linear system of equations that needs to be solved for pCT image reconstruction. The hull-detection algorithms investigated here included silhouette/space carvin…
▽ More
Proton computed tomography (pCT) is a novel imaging modality developed for patients receiving proton radiation therapy. The purpose of this work was to investigate hull-detection algorithms used for preconditioning of the large and sparse linear system of equations that needs to be solved for pCT image reconstruction. The hull-detection algorithms investigated here included silhouette/space carving (SC), modified silhouette/space carving (MSC), and space modeling (SM). Each was compared to the cone-beam version of filtered backprojection (FBP) used for hull-detection. Data for testing these algorithms included simulated data sets of a digital head phantom and an experimental data set of a pediatric head phantom obtained with a pCT scanner prototype at Loma Linda University Medical Center. SC was the fastest algorithm, exceeding the speed of FBP by more than 100 times. FBP was most sensitive to the presence of noise. Ongoing work will focus on optimizing threshold parameters in order to define a fast and efficient method for hull-detection in pCT image reconstruction.
△ Less
Submitted 7 February, 2014;
originally announced February 2014.