Evaluation of an Open-Source Pipeline to Create Patient-Specific Left Atrial Models: A Reproducibility Study
Authors:
Jose Alonso Solis-Lemus,
Tiffany Baptiste,
Rosie Barrows,
Charles Sillett,
Ali Gharaviri,
Giulia Raffaele,
Orod Razeghi,
Marina Strocchi,
Iain Sim,
Irum Kotadia,
Neil Bodagh,
Daniel O'Hare,
Mark O'Neill,
Steven E Williams,
Caroline Roney,
Steven Niederer
Abstract:
We present an open-source software pipeline to create patient-specific left atrial (LA) models with fibre orientations and a fibrosis map, suitable for electrophysiology simulations. The semi-automatic pipeline takes as input a contrast enhanced magnetic resonance angiogram, and a late gadolinium enhanced (LGE) contrast magnetic resonance (CMR). Five operators were allocated 20 cases each from a s…
▽ More
We present an open-source software pipeline to create patient-specific left atrial (LA) models with fibre orientations and a fibrosis map, suitable for electrophysiology simulations. The semi-automatic pipeline takes as input a contrast enhanced magnetic resonance angiogram, and a late gadolinium enhanced (LGE) contrast magnetic resonance (CMR). Five operators were allocated 20 cases each from a set of 50 CMR datasets to create a total of 100 models to evaluate inter/intra-operator variability. Each output model consisted of (1) a labelled surface mesh open at the pulmonary veins (PV) and mitral valve (MV), (2) fibre orientations mapped from a diffusion tensor MRI human atlas, (3) fibrosis map from the LGE-CMR scan, and (4) simulation of local activation time (LAT) and phase singularity (PS) mapping. We evaluated reproducibility in our pipeline by comparing agreement in shape of the output meshes, fibrosis distribution in the LA body, and fibre orientations; simulations outputs were evaluated comparing total activation times of LAT maps, mean conduction velocity (CV), and structural similarity index measure (SSIM) of PS maps. Our workflow allows a single model to be created in 16.72 +/- 12.25 minutes. Results in this abstract are reported as inter/intra. Shape only differed noticeably with users' selection of the MV and the length of the PV from the ostia to the distal end; fibrosis agreement (0.91/0.99 ICC) and fibre orientation agreement (60.63/71.77 %) were high. LAT maps showed good agreement, the median of the absolute difference of the total activation times was 2.02ms/1.37ms. The average of the mean CV difference was -4.04mm/s / 2.1mm/s. PS maps showed a moderately good agreement with SSIM of 0.648/0.608. Although we found notable differences in the models due to user input, our tests show that operator variability was comparable to that of image resolution or fibre estimation.
△ Less
Submitted 9 May, 2023; v1 submitted 17 January, 2023;
originally announced January 2023.
Gaussian Process Manifold Interpolation for Probabilistic Atrial Activation Maps and Uncertain Conduction Velocity
Authors:
Sam Coveney,
Cesare Corrado,
Caroline H Roney,
Daniel O'Hare,
Steven E Williams,
Mark D O'Neill,
Steven A Niederer,
Richard H Clayton,
Jeremy E Oakley,
Richard D Wilkinson
Abstract:
In patients with atrial fibrillation, local activation time (LAT) maps are routinely used for characterising patient pathophysiology. The gradient of LAT maps can be used to calculate conduction velocity (CV), which directly relates to material conductivity and may provide an important measure of atrial substrate properties. Including uncertainty in CV calculations would help with interpreting the…
▽ More
In patients with atrial fibrillation, local activation time (LAT) maps are routinely used for characterising patient pathophysiology. The gradient of LAT maps can be used to calculate conduction velocity (CV), which directly relates to material conductivity and may provide an important measure of atrial substrate properties. Including uncertainty in CV calculations would help with interpreting the reliability of these measurements. Here, we build upon a recent insight into reduced-rank Gaussian processes (GP) to perform probabilistic interpolation of uncertain LAT directly on human atrial manifolds. Our Gaussian Process Manifold Interpolation (GPMI) method accounts for the topology of the atria, and allows for calculation of statistics for predicted CV. We demonstrate our method on two clinical cases, and perform validation against a simulated ground truth. CV uncertainty depends on data density, wave propagation direction, and CV magnitude. GPMI is suitable for probabilistic interpolation of other uncertain quantities on non-Euclidean manifolds.
△ Less
Submitted 23 April, 2020; v1 submitted 22 April, 2020;
originally announced April 2020.